neutral particle analyzer
Recently Published Documents


TOTAL DOCUMENTS

79
(FIVE YEARS 23)

H-INDEX

12
(FIVE YEARS 2)

2022 ◽  
Vol 92 (1) ◽  
pp. 45
Author(s):  
И.М. Балаченков ◽  
Н.Н. Бахарев ◽  
В.И. Варфоломеев ◽  
В.К. Гусев ◽  
М.В. Ильясова ◽  
...  

With an increase of magnetic field up to 0.8 T and plasma current to 400 kA, fast ion losses rate in the discharges with toroidal Alfven eigenmodes decreased in tokamak Globus-M2 comparing with Globus-M tokamak discharges. Taking into account the data on the discharges with increased magnetic field and plasma current, the regression fit of neutral particle analyzer flux drop in energy channel close to neutral beam energy on relative eigenmode magnitude, the value of magnetic field and plasma current was analyzed. The power of flux drop dependence on TAE magnitude was found to be ~0.5 and inverse proportional on the value of product of magnetic field and plasma current, which is highly likely is determined only by plasma current due to weak dependence on magnetic field. The result obtained indicates that fast ion losses in Globus-M2, stimulated by toroidal Alfven eigenmodes are mostly determined by the shift of passing orbits to the plasma edge. With the increase of plasma current and magnetic field, neutron flux drops arising in the moments of toroidal mode bursts have also decreased.


2021 ◽  
Vol 32 (7) ◽  
Author(s):  
Yuan Luo ◽  
Wei-Ping Lin ◽  
Pei-Pei Ren ◽  
Guo-Feng Qu ◽  
Jing-Jun Zhu ◽  
...  

2021 ◽  
Vol 92 (5) ◽  
pp. 053542
Author(s):  
G. Player ◽  
R. Clary ◽  
S. Dettrick ◽  
S. Korepanov ◽  
R. M. Magee ◽  
...  

2021 ◽  
Vol 92 (4) ◽  
pp. 043554
Author(s):  
J. Rueda-Rueda ◽  
M. García-Muñoz ◽  
E. Viezzer ◽  
P. A. Schneider ◽  
J. García-Domínguez ◽  
...  

2021 ◽  
pp. 25-30
Author(s):  
A.S. Slavnyj ◽  
R.O. Pavlichenko ◽  
A.N. Shapoval ◽  
M.N. Makhov ◽  
M.B. Dreval

Charge exchange (CX) neutral fluxes were measured by neutral particle analyzer (NPA) in plasma discharges sustained by the W7-X-like radio frequency (RF) antenna in the Uragan-2M (U-2M) stellarator. CX fluxes in pure hydrogen discharge (B0 = 0.36 T, f = 4.926 MHz) in stellarator configuration (effective perpendicular ion temperature TꞱ ≈ 450 eV) is less energetic in comparison with U-2M hybrid configuration (TꞱ ≈ 800 eV). RF discharge in stellarator configuration with helium and hydrogen mixture (B0 = 0.351 T; f = 5.156 MHz, P = 6·10-4Torr) shows more energetic CX fluxes (TꞱ ≈ 1 keV). The ion cyclotron frequency distribution across the U-2M plasma has been studied numerically. These calculations are accompanied by direct measurement of the RF frequency by magnetic sensor. The ion cyclotron frequency is present in plasma bulk of all discharges under consideration.


Author(s):  
А.Ю. Тельнова ◽  
И.В. Мирошников ◽  
М.М. Митранкова ◽  
Н.Н. Бахарев ◽  
В.К. Гусев ◽  
...  

The paper presents the first ion temperature profile measurements results in the new spherical tokamak Globus-M2, which were obtained in discharges with neutral beam injection using the Charge eXchange Recombination Spectroscopy (CXRS) and the Neutral Particle Analyzer (NPA). Ion heat transport modeling using ASTRA code was carried out based on the obtained experimental ion temperature. The results of the modelling indicate the predominantly neoclassical ion heat transport.


2020 ◽  
Vol 62 (10) ◽  
pp. 105008
Author(s):  
B. Geiger ◽  
L. Stagner ◽  
W.W. Heidbrink ◽  
R. Dux ◽  
R. Fischer ◽  
...  

2020 ◽  
Vol 60 (11) ◽  
pp. 112008
Author(s):  
D.J. Lin ◽  
X.D. Du ◽  
W.W. Heidbrink ◽  
M.A. Van Zeeland

Sign in / Sign up

Export Citation Format

Share Document