grin lens
Recently Published Documents


TOTAL DOCUMENTS

187
(FIVE YEARS 40)

H-INDEX

16
(FIVE YEARS 3)

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Luis Fernando Cobar ◽  
Alireza Kashef ◽  
Krishnashish Bose ◽  
Ayumu Tashiro

AbstractElectrical and optical monitoring of neural activity is major approaches for studying brain functions. Each has its own set of advantages and disadvantages, such as the ability to determine cell types and temporal resolution. Although opto-electrical bimodal recording is beneficial by enabling us to exploit the strength of both approaches, it has not been widely used. In this study, we devised three methods of bimodal recording from a deep brain structure in awake head-fixed mice by chronically implanting a gradient-index (GRIN) lens and electrodes. First, we attached four stainless steel electrodes to the side of a GRIN lens and implanted them in a mouse expressing GCaMP6f in astrocytes. We simultaneously recorded local field potential (LFP) and GCaMP6f signal in astrocytes in the hippocampal CA1 area. Second, implanting a silicon probe electrode mounted on a custom-made microdrive within the focal volume of a GRIN lens, we performed bimodal recording in the CA1 area. We monitored LFP and fluorescent changes of GCaMP6s-expressing neurons in the CA1. Third, we designed a 3D-printed scaffold to serve as a microdrive for a silicon probe and a holder for a GRIN lens. This scaffold simplifies the implantation process and makes it easier to place the lens and probe accurately. Using this method, we recorded single unit activity and LFP electrically and GCaMP6f signals of single neurons optically. Thus, we show that these opto-electrical bimodal recording methods using a GRIN lens and electrodes are viable approaches in awake head-fixed mice.


2021 ◽  
Author(s):  
Tara Urner ◽  
Andrew Inman ◽  
Ben Lapid ◽  
Shu Jia

2021 ◽  
Author(s):  
Primala Thapa ◽  
Sunil Bhatt ◽  
Veena Singh ◽  
Shilpa Tayal ◽  
Priyanka Mann ◽  
...  

2021 ◽  
Author(s):  
Chunyan Li ◽  
Gengpeng Li ◽  
Jihong Liu ◽  
Dou Luo ◽  
Jiayi Liu

2021 ◽  
Vol 60 (09) ◽  
Author(s):  
Chunyan Li ◽  
Gengpeng Li ◽  
Jihong Liu ◽  
Dou Luo ◽  
Jiayi Liu

Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3392
Author(s):  
Guigen Liu ◽  
Jeon Woong Kang ◽  
Oliver Jonas

We analytically investigate the feasibility of long graded-index (GRIN)-lens-based microendoscopes through wavefront shaping. Following the very well-defined ray trajectories in a GRIN lens, mode-dependent phase delay is first determined. Then, the phase compensation needed for obtaining diffraction limited resolution is derived. Finally, the diffraction pattern of the lens output is computed using the Rayleigh–Sommerfeld diffraction theory. We show that diffraction-limited resolution is obtained for a 0.5 mm diameter lens with a length over 1 m. It is also demonstrated that different imaging working distances (WDs) can be realized by modifying the phase compensation. When a short design WD is used, a large imaging numerical aperture (NA) higher than 0.4 is achievable even when a low NA lens (NA = 0.1) is used. The long- and thin-GRIN-lens-based microendoscope investigated here, which is attractive for biomedical applications, is being prioritized for use in a clinical stage microdevice that measures three-dimensional drug responses inside the body. The advance described in this work may enable superior imaging capabilities in clinical applications in which long and flexible imaging probes are favored.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1552
Author(s):  
Gorkem Okudan ◽  
Hrishikesh Danawe ◽  
Lu Zhang ◽  
Didem Ozevin ◽  
Serife Tol

Phononic crystals have the ability to manipulate the propagation of elastic waves in solids by generating unique dispersion characteristics. They can modify the conventional behavior of wave spreading in isotropic materials, known as attenuation, which negatively influences the ability of acoustic emission method to detect active defects in long-range, pipe-like structures. In this study, pipe geometry is reconfigured by adding gradient-index (GRIN) phononic crystal lens to improve the propagation distance of waves released by active defects such as crack growth and leak. The sensing element is designed to form a ring around the pipe circumference to capture the plane wave with the improved amplitude. The GRIN lens is designed by a special gradient-index profile with varying height stubs adhesively bonded to the pipe surface. The performance of GRIN lens for improving the amplitude of localized sources is demonstrated with finite element numerical model using multiphysics software. Experiments are conducted using pencil lead break simulating crack growth, as well as an orifice with pressured pipe simulating leak. The amplitude of the burst-type signal approximately doubles on average, validating the numerical findings. Hence, the axial distance between sensors can be increased proportionally in the passive sensing of defects in pipe-like geometries.


2020 ◽  
Author(s):  
Young Been Han ◽  
Seong Hyun Song ◽  
Han Gyu Kang ◽  
Ho-Young Lee ◽  
Seong Jong Hong
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document