ultrafine metal particles
Recently Published Documents


TOTAL DOCUMENTS

60
(FIVE YEARS 3)

H-INDEX

18
(FIVE YEARS 0)

Author(s):  
Li Li ◽  
Pei Niu ◽  
Xuan Wang ◽  
Fangbo Bing ◽  
Wenchang Tan ◽  
...  

It is not clear for inhalation of ultrafine metal particles in air pollution to impair human health. In the study, we aimed to investigate whether short-term (4 weeks) inhalation of ultrafine zinc particles could deteriorate the cardiac and hemodynamic functions in rats of myocardial infarction (MI). MI was induced in Wistar rats through coronary artery ligation surgery and given an inhalation of ultrafine zinc particles for 4 weeks (post-MI 4 weeks, 4 days per week, and 4 h per day). Cardiac strain and strain rate were quantified by the speckle tracking echocardiography. The pressure and flow wave were recorded in the carotid artery and analyzed by using the Womersley model. Myocardial infarction resulted in the LV wall thinning, LV cavity dilation, remarkable decrease of ejection fraction, dp/dt Max, −dp/dt Min, myocardial strain and strain rates, and increased LV end-diastolic pressure, as well as impaired hemodynamic environment. The short-term inhalation of ultrafine zinc particles significantly alleviated cardiac and hemodynamic dysfunctions, which could protect from the MI-induced myocardial and hemodynamic impairments albeit it is unknown for the long-term inhalation.


2014 ◽  
Vol 4 (1) ◽  
pp. 11-17 ◽  
Author(s):  
Edward McPherson, M.D., FACS ◽  
Matthew Dipane, BA ◽  
Sherif Sherif, MD

This report reviews the findings of a massive pseudotumor detected pre-operatively in a 13-year-old revision total hip arthroplasty. The case is unique in that the bearing involved was a 28mm zirconia ceramic head on a polyethylene liner. We propose that the pseudotumor arose from ultrafine titanium particles liberated from the proximal porous coating of the femoral stem. We suspect that the osteolysis produced from polyethylene wear exposed the proximal porous coating and, via a process of mechanical abrasion with the surrounding soft tissues, liberated ultrafine titanium particles. We believe the pseudotumor formed because the patient was pre-sensitized to metal debris based upon a pre-operative lymphocyte T-cell proliferation test (LTT). Based upon this unique case, we feel that pseudotumors more likely form when there is a high rate of ultrafine metal particles generated in a pre-sensitized patient. Finally, we introduce what we believe are the main biologic wear responses in THA. Further research is needed to validate this proposed model.Keywords: pseudotumor, ceramic, polyethylene, osteolysis, THA, bearing wear eesponse, titanium debrisLevel of Evidence:  AAOS Therapeutic Study Level IV


Sign in / Sign up

Export Citation Format

Share Document