biaxial flexural strength
Recently Published Documents


TOTAL DOCUMENTS

125
(FIVE YEARS 44)

H-INDEX

18
(FIVE YEARS 3)

Author(s):  
Niwut Juntavee ◽  
Apa Juntavee ◽  
Thipradi Phattharasophachai

Abstract Objective Different post-sintering processes are expected to be a reason for alteration in the strength of zirconia. This study evaluated the effect of post-sintering processes on the flexural strength of different types of monolithic zirconia. Materials and Methods A total of 120 classical- (Cz) and high-translucent (Hz) monolithic zirconia discs (1.2 mm thickness and 14 mm in Ø) were prepared, sintered, and randomly divided into four groups to be surface-treated with (1) as-glazed (AG); (2) finished and polished (FP); (3) finished, polished, and overglazed (FPOG); and (4) finished, polished, and heat-treated (FPHT) technique (n = 15). Biaxial flexural strength (σ) was determined on a piston-on-three ball in a universal testing machine at a speed of 0.5 mm/min. Statistical Analysis Analysis of variance, and post hoc Bonferroni multiple comparisons were determined for significant differences (α = 0.05). Weibull analysis was applied for survival probability, Weibull modulus (m), and characteristic strength (σ0). The microstructures were examined with a scanning electron microscope and X-ray diffraction. Results The mean ± standard deviation value of σ (MPa), m, and σ0 were 1,626.43 ± 184.38, 9.51, and 1,709.79 for CzAG; 1,734.98 ± 136.15, 12.83, and 1,799.17 for CzFP; 1,636.92 ± 130.11, 14.66, and 1,697.63 for CzFPOG; and 1,590.78 ± 161.74, 10.13, and 1,663.82 for CzFPHT; 643.30 ± 118.59, 5.59, and 695.55 for HzAG; 671.52 ± 96.77, 3.28, and 782.61 for HzFP; 556.33 ± 122.85, 4.76, and 607.01 for HzFPOG; and 598.36 ± 57.96, 11.22, and 624.89 for HzFPHT. The σ was significantly affected by the post-sintering process and type of zirconia (p < 0.05), but not by their interactions (p > 0.05). The Cz indicated a significantly higher σ than Hz. The FP process significantly enhanced σ more than other treatment procedures. Conclusion Post-sintering processes enabled an alteration in σ of zirconia. FP enhanced σ, while FPOG and FPHT resulted in a reduction of σ. Glazing tends to induce defects at the glazing interface, while heat treatment induces a phase change to tetragonal, both resulted in reducing σ. Finishing and polishing for both Cz and Hz monolithic zirconia is recommended, while overglazed or heat-treated is not suggested.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 244
Author(s):  
Reem AlMutairi ◽  
Hend AlNahedh ◽  
Ahmed Maawadh ◽  
Ahmed Elhejazi

In this study, the biaxial flexural strength (BFS) and fractography of high/ultra-translucent monolithic zirconia ceramics subjected to different mechanical surface pretreatments were evaluated. A total of 108 disc-shaped samples (12 mm diameter, 1.2 mm thickness) of three zirconia materials (5Y-ZP KATANA Zirconia UTML (ML), 3Y-TZP DD Bio ZX2 (DB), and 5Y-ZP DD cube X2 (DC)) were used. The BFS was investigated after subjecting the samples to surface treatment using air abrasion particles of two types (aluminum oxide or glass microbeads). The data were analyzed using two-way analysis of variance, followed by Scheffe’s post hoc test for multiple comparisons. The mean ± standard deviation BFS for DB was highest after treatment with 50 µm Al2O3 (1626.05 ± 31.9 MPa), with lower values being observed following treatment with 50 µm glass microbeads (1399.53 ± 24.2 MPa) and in the control sample (1198.51 ± 21.1 MPa). The mean ± standard deviation (SD) BFSs for DC and ML were the highest in the control groups. Surface air abrasion with 50 µm Al2O3 particles and 2 bar pressure is recommended for 3Y-TZP translucent zirconia, while no abrasion of 5Y-ZP translucent zirconia ceramic.


2021 ◽  
Vol 12 (4) ◽  
pp. 73
Author(s):  
Supachai Chanachai ◽  
Wirinrat Chaichana ◽  
Kanlaya Insee ◽  
Sutiwa Benjakul ◽  
Visakha Aupaphong ◽  
...  

Enamel demineralization around orthodontic adhesive is a common esthetic concern during orthodontic treatment. The aim of this study was to prepare orthodontic adhesives containing monocalcium phosphate monohydrate (MCPM) and nisin to enable mineralizing and antibacterial actions. The physicomechanical properties and the inhibition of S. mutans growth of the adhesives with added MCPM (5, 10 wt %) and nisin (5, 10 wt %) were examined. Transbond XT (Trans) was used as the commercial comparison. The adhesive containing a low level of MCPM showed significantly higher monomer conversion (42–62%) than Trans (38%) (p < 0.05). Materials with additives showed lower monomer conversion (p < 0.05), biaxial flexural strength (p < 0.05), and shear bond strength to enamel than those of a control. Additives increased water sorption and solubility of the experimental materials. The addition of MCPM encouraged Ca and P ion release, and the precipitation of calcium phosphate at the bonding interface. The growth of S. mutans in all the groups was comparable (p > 0.05). In conclusion, experimental orthodontic adhesives with additives showed comparable conversion but lesser mechanical properties than the commercial material. The materials showed no antibacterial action, but exhibited ion release and calcium phosphate precipitation. These properties may promote remineralization of the demineralized enamel.


Polymers ◽  
2021 ◽  
Vol 13 (22) ◽  
pp. 3902
Author(s):  
Pipop Saikaew ◽  
Patchara Phimolthares ◽  
Pheeratas Phitakthanaakul ◽  
Panthira Sirikul ◽  
Suwannee Mekrakseree ◽  
...  

Color modifiers can be mixed with resin composites to mimic the shade of severely discolored tooth. The aim of this study was to assess the effects of a color modifier on the physical and mechanical properties of a resin composite. The composite was mixed with a color modifier at 0 wt% (group 1), 1 wt% (group 2), 2.5 wt% (group 3), or 5 wt% (group 4). The degree of monomer conversion (DC) was examined after light curing for 20 or 40 s. Biaxial flexural strength (BFS)/modulus (BFM), surface microhardness (SH), and water sorption (Wsp)/solubility (Wsl) were also tested. The DC of group 1 was significantly higher than that of groups 3 and 4. The increase in curing time from 20 to 40 s increased the DC by ~10%. The BFS, BFM, Wsp, and Wsl of all the groups were comparable. A negative correlation was detected between the concentration of color modifier and the BFS and DC, while a positive correlation was observed with Wsp. In conclusion, the color modifier reduced the DC of composites, but the conversion was improved by extending the curing time. The increase in color modifier concentration also correlated with a reduction in strength and the increase in the water sorption of the composites.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Niwut Juntavee ◽  
Apa Juntavee ◽  
Sirintana Phetpanompond

Introduction. High-translucence ceramics have been used increasingly. This study evaluated the biaxial flexural strength of different ceramics as a result of varying thicknesses. Materials and Methods. Circular discs with varied thickness of 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, and 2.0 mm were prepared from high-translucence yttria-partially stabilized zirconia (HTY-PSZ); Bruxzir® Anterior (Bc), and zirconia-reinforced lithium silicate (ZLS) including Celtra® DUO (Cc) and VITA Suprinity® (Vc) (n = 15 discs/group). Biaxial flexural strength (σ) was evaluated utilizing piston-on-three-balls in a testing machine at a speed of 0.5 mm/min. A scanning electron microscope (SEM) was used to determine the microscopic structure. ANOVA and multiple comparisons were analyzed for significant differences (a = 0.05). Results. The mean ± sd value of σ (MPa) for thickness 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, and 2.0 mm was 672.66 ± 107.54, 655.93 ± 93.98, 589.01 ± 63.63, 624.89 ± 87.08, 618.82 ± 83.36, 672.64 ± 84.61, 659.81 ± 122.89, 632.79 ± 92.54, and 657.86 ± 73.17, for Bc; 477.64 ± 88.23, 496.39 ± 86.36, 461.56 ± 57.00, 450.26 ± 86.60, 468.28 ± 83.65, 472.45 ± 53.63, 453.05 ± 72.50, 462.67 ± 47.57, and 535.28 ± 84.33, for Cc; and 500.97 ± 76.36, 506.70 ± 87.76, 557.82 ± 62.78, 543.76 ± 87.29, 507.53 ± 86.09, 502.46 ± 64.75, 557.70 ± 80.91, 527.04 ± 80.78, and 499.88 ± 57.35, for Vc. A significant difference in flexural strength was indicated among groups ( p < 0.05 ). Bc was significantly stronger than Cc and Vc ( p < 0.05 ). Varying thickness did not have a significant influence on strength ( p > 0.05 ). SEM revealed a tight arrangement of crystals for Bc and needle-like crystals diffusing in glass for Vc and Cc. Conclusion. Flexural strength of ceramics varied among types, but each retained strength equitably with varying thickness. HTY-PSZ was stronger than ZLS, but each was equally strong for thickness in the range of 0.4–2.0 mm.


Polymers ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 2742
Author(s):  
Wisitsin Potiprapanpong ◽  
Whithipa Thepveera ◽  
Chutikarn Khamsuk ◽  
Somruethai Channasanon ◽  
Siriporn Tanodekaew ◽  
...  

The aim of this study was to prepare RMGICs for pulp protection that contain polyacids functionalized with methacrylate groups (CMs) to enable light-activated polymerization without the need for toxic 2-hydroxyethyl methacrylate (HEMA) monomers. The effects of using CM liquids with 0 or 5 wt% HEMA on the physical/mechanical properties and cytotoxicity of the experimental RMGICs were assessed. Spherical pre-reacted glass fillers (SPG) were used as the powder phase. The experimental RMGICs were prepared by mixing SPG with CM liquid (0 wt% HEMA, F1) or CMH liquid (5 wt% HEMA, F2). Commercial materials (Vitrebond, VB; TheraCal LC, TC) were used for the comparisons. The degree of monomer conversion and fluoride release of both F1 and F2 were significantly lower than those of VB. F1 showed comparable biaxial flexural strength with VB but higher strength than TC. The dimensional stability (mass/volume changes) of the experimental materials was comparable with that of the commercial materials. F1 and F2 exhibited higher Sr/Ca ion release and relative cell viability than VB. The use of CMH liquid reduced the strength but enhanced the fluoride release of the experimental RMGICs. In conclusion, the experimental RMGICs showed comparable strength but lower cytotoxicity compared to the commercial RMGICs. These novel materials could be used as alternative materials for pulp protection.


Materials ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3694
Author(s):  
Hiroto Nakai ◽  
Masanao Inokoshi ◽  
Kosuke Nozaki ◽  
Keiji Komatsu ◽  
Shingo Kamijo ◽  
...  

We aimed to assess the crystallography, microstructure and flexural strength of zirconia-based ceramics made by stereolithography (SLA). Two additively manufactured 3 mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP: LithaCon 3Y 230, Lithoz; 3D Mix zirconia, 3DCeram Sinto) and one alumina-toughened zirconia (ATZ: 3D Mix ATZ, 3DCeram Sinto) were compared to subtractively manufactured 3Y-TZP (control: LAVA Plus, 3M Oral Care). Crystallographic analysis was conducted by X-ray diffraction. Top surfaces and cross-sections of the subsurface microstructure were characterized using scanning electron microscopy (SEM). Biaxial flexural strength was statistically compared using Weibull analysis. The additively and subtractively manufactured zirconia grades revealed a similar phase composition. The residual porosity of the SLA 3Y-TZPs and ATZ was comparable to that of subtractively manufactured 3Y-TZP. Weibull analysis revealed that the additively manufactured LithaCon 3Y 230 (Lithoz) had a significantly lower biaxial flexural strength than 3D Mix ATZ (3D Ceram Sinto). The biaxial flexural strength of the subtractively manufactured LAVA Plus (3M Oral Care) was in between those of the additively manufactured 3Y-TZPs, with the additively manufactured ATZ significantly outperforming the subtractively manufactured 3Y-TZP. Additively manufactured 3Y-TZP showed comparable crystallography, microstructure and flexural strength as the subtractively manufactured zirconia, thus potentially being a good option for dental implants.


Sign in / Sign up

Export Citation Format

Share Document