auditory evoked fields
Recently Published Documents


TOTAL DOCUMENTS

71
(FIVE YEARS 5)

H-INDEX

18
(FIVE YEARS 2)

Symmetry ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1748
Author(s):  
Dawei Shen ◽  
Claude Alain ◽  
Bernhard Ross

The presence of binaural low-level background noise has been shown to enhance the transient evoked N1 response at about 100 ms after sound onset. This increase in N1 amplitude is thought to reflect noise-mediated efferent feedback facilitation from the auditory cortex to lower auditory centers. To test this hypothesis, we recorded auditory-evoked fields using magnetoencephalography while participants were presented with binaural harmonic complex tones embedded in binaural or monaural background noise at signal-to-noise ratios of 25 dB (low noise) or 5 dB (higher noise). Half of the stimuli contained a gap in the middle of the sound. The source activities were measured in bilateral auditory cortices. The onset and gap N1 response increased with low binaural noise, but high binaural and low monaural noise did not affect the N1 amplitudes. P1 and P2 onset and gap responses were consistently attenuated by background noise, and noise level and binaural/monaural presentation showed distinct effects. Moreover, the evoked gamma synchronization was also reduced by background noise, and it showed a lateralized reduction for monaural noise. The effects of noise on the N1 amplitude follow a bell-shaped characteristic that could reflect an optimal representation of acoustic information for transient events embedded in noise.


2021 ◽  
Author(s):  
Robert A Seymour ◽  
Nicholas Alexander ◽  
Stephanie J Mellor ◽  
George C O'Neill ◽  
Tim M Tierney ◽  
...  

Optically pumped magnetometer-based magnetoencephalography (OP-MEG) can be used to measure neuromagnetic fields while participants move in a magnetically shielded room. Head movements in previous OP-MEG studies have been up to 20 cm translation and ~30 degrees rotation in a sitting position. While this represents a step-change over static MEG systems, naturalistic head movement is likely to exceed these limits, particularly when participants are standing up. In this proof-of-concept study, we sought to push the movement limits of OP-MEG even further. Using a 90 channel (45-sensor) whole-head OP-MEG system and concurrent motion capture, we recorded auditory evoked fields while participants were: (i) sitting still, (ii) standing up and still, and (iii) standing up and making large natural head movements continuously throughout the recording - maximum translation 120 cm, maximum rotation 198 degrees. Following pre-processing, movement artefacts were substantially reduced but not eliminated. However, upon utilisation of a beamformer, the M100 event-related field localised to primary auditory regions. Furthermore, the event-related fields from auditory cortex were remarkably consistent across the three conditions. These results suggest that a wide range of movement is possible with current OP-MEG systems. This in turn underscores the exciting potential of OP-MEG for recording neural activity during naturalistic paradigms that involve movement (e.g. navigation), and for scanning populations who are difficult to study with static MEG (e.g. young children).


2020 ◽  
Vol 9 (5) ◽  
pp. 247-251
Author(s):  
Tilmann Sander ◽  
Anna Jodko-Władzińska ◽  
Stefan Hartwig ◽  
Rüdiger Brühl ◽  
Thomas Middelmann

AbstractThe electrophysiological activities in the human body generate electric and magnetic fields that can be measured noninvasively by electrodes on the skin, or even, not requiring any contact, by magnetometers. This includes the measurement of electrical activity of brain, heart, muscles and nerves that can be measured in vivo and allows to analyze functional processes with high temporal resolution. To measure these extremely small magnetic biosignals, traditionally highly sensitive superconducting quantum-interference devices have been used, together with advanced magnetic shields. Recently, they have been complemented in usability by a new class of sensors, optically pumped magnetometers (OPMs). These quantum sensors offer a high sensitivity without requiring cryogenic temperatures, allowing the design of small and flexible sensors for clinical applications. In this letter, we describe the advantages of these upcoming OPMs in two exemplary applications that were recently carried out at Physikalisch-Technische Bundesanstalt (PTB): (1) magnetocardiography (MCG) recorded during exercise and (2) auditory-evoked fields registered by magnetoencephalography.


2019 ◽  
Author(s):  
Christoph Pfeiffer ◽  
Silvia Ruffieux ◽  
Lars Jönsson ◽  
Maxim L. Chukharkin ◽  
Alexei Kalaboukhov ◽  
...  

AbstractDue to their higher operating temperature, high-Tc superconducting quantum interference devices (SQUIDs) require less thermal insulation than the low-Tc sensors that are utilized in commercial magnetoen-cephalography (MEG) systems. As a result, they can be placed closer to the head, where neuromagnetic fields are higher and more focal, potentially leading to higher spatial resolution. The first such on-scalp MEG measurements using high-Tc SQUIDs have shown the potential of the technology. In order to be useful for neuroscience and clinical applications, however, multi-channel systems are required. Herein, we present a 7-channel on-scalp MEG system based on high-Tc SQUIDs. The YBCO SQUID magnetometers are arranged in a dense, head-aligned hexagonal array inside a single, liquid nitrogen-cooled cryostat. The spacing between the magnetometers and the head is adjustable down to 1 mm. The sensors are side-mounted on the cryostat that is mounted on an articulated armature for recordings on arbitrary head locations of a seated subject. We demonstrate white noise levels of 50-130 fT/Hz1/2 at 10 Hz, sensor-to-sensor crosstalk values of <0.6%, and single-fill operation times of 16 hours. We validate the system with MEG recordings of visual alpha modulation and auditory evoked fields. The system is thus useful for densely and sensitively sampling neuromagnetic fields over any ∼ 10 cm2 patch of the scalp surface over the course of a day.


PLoS ONE ◽  
2017 ◽  
Vol 12 (1) ◽  
pp. e0170166
Author(s):  
Izumi Yahata ◽  
Tetsuaki Kawase ◽  
Akitake Kanno ◽  
Hiroshi Hidaka ◽  
Shuichi Sakamoto ◽  
...  

2014 ◽  
Vol 112 (12) ◽  
pp. 3053-3065 ◽  
Author(s):  
G. Björn Christianson ◽  
Maria Chait ◽  
Alain de Cheveigné ◽  
Jennifer F. Linden

In animal models, single-neuron response properties such as stimulus-specific adaptation have been described as possible precursors to mismatch negativity, a human brain response to stimulus change. In the present study, we attempted to bridge the gap between human and animal studies by characterising responses to changes in the frequency of repeated tone series in the anesthetised guinea pig using small-animal magnetoencephalography (MEG). We showed that 1) auditory evoked fields (AEFs) qualitatively similar to those observed in human MEG studies can be detected noninvasively in rodents using small-animal MEG; 2) guinea pig AEF amplitudes reduce rapidly with tone repetition, and this AEF reduction is largely complete by the second tone in a repeated series; and 3) differences between responses to the first (deviant) and later (standard) tones after a frequency transition resemble those previously observed in awake humans using a similar stimulus paradigm.


Sign in / Sign up

Export Citation Format

Share Document