difficult placement
Recently Published Documents


TOTAL DOCUMENTS

16
(FIVE YEARS 4)

H-INDEX

3
(FIVE YEARS 0)

2021 ◽  
Vol 5 (Supplement_1) ◽  
pp. 46-47
Author(s):  
Trisha Gaudig

Abstract The Sioux Falls VA Community Living Center (CLC) is a partner site for the Behavioral Recovery Outreach (BRO) Team dissemination. This CLC is home to over 55 Veterans requiring a variety of specialty needs such as dementia care, short-term rehabilitation, respite, hospice, and/or psychosocial needs. Many of the Veterans followed by the BRO Team on the CLC experienced frequent rehospitalizations and difficult placement in the community due to behavioral concerns. Local leadership encouraged participation in the BRO Team dissemination due to the growing need in this VA system to open access to dementia and mental health care, successfully discharge Veterans to appropriate community settings, and reduce unnecessary rehospitalizations. This presentation will discuss BRO Team development, including several factors facilitating successful BRO Team implementation (e.g., leadership support, community outreach approaches, staff partner buy-in), and identify barriers impacting successful implementation with a case example to illustrate strategies to overcome such barriers.


2019 ◽  
Vol 4 (2) ◽  
pp. 71-74
Author(s):  
Thomas A. Paterniti ◽  
Lee Weber ◽  
Gene Krishingner ◽  
Sarfraz Ahmad

Introduction: Essure® device malposition is a rare, but clinically significant complication, for which management is idiosyncratic. This case report describes an unusual example of Essure® migration in order to clarify reasonable management options. Case Presentation: A 50-year old G4 P2022 underwent hysteroscopic sterilization using the Essure® device. Insertion was complicated by fragmentation of both coils. Two years later, one of the coils was incidentally discovered protruding through the cervical os. The visible portion was clipped when attempts to remove the entire coil were unsuccessful. Conclusion: Difficult placement increases the risk of Essure® malposition. In asymptomatic patients, conservative management with removal of only a portion of the device is a rational approach.


F1000Research ◽  
2017 ◽  
Vol 6 ◽  
pp. 616
Author(s):  
Pieter J. Schraverus ◽  
Suzanne van Rijswijk ◽  
Pieter Roel Tuinman

Peripheral intravenous (IV) catheters can break off while still in the patient, with possible detrimental effects such as upstream migration to the heart. These catheters have probably been damaged by the needle during a difficult insertion. A peripheral IV catheter was removed in a 90 year old patient and only half of the catheter was retrieved. By using ultrasound examination the remaining part of the IV catheter was identified, and retrieved surgically, before it could migrate towards the heart. This case report suggests that ultrasound should not only be used for difficult placement of a peripheral IV catheter, but can also be used when removal is complicated.


2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Isamarie Lora Alcantara ◽  
Shadi Rezai ◽  
Catherine Kirby ◽  
Annika Chadee ◽  
Cassandra E. Henderson ◽  
...  

Background. Hysteroscopic tubal sterilization (Essure) is a minimally invasive option for permanent contraception with high reported rates of patient satisfaction. A small percentage of these women subsequently choose to have the tubal inserts removed due to regret or perceived side effects such as late-onset pelvic pain secondary to placement of the Essure device.Case. A twenty-nine-year-old woman G4P4014 presented with a two-year complaint of chronic pelvic pain and dyspareunia after the hysteroscopic placement of an Essure device for sterilization. On reviewing the images of the HSG, it was noted that although tubal occlusion was confirmed, the left Essure coil appeared curved on itself in an elliptical fashion and did not seem to follow the expected anatomic trajectory of the fallopian tube. The patient reported resolution of chronic pelvic pain following laparoscopic removal of Essure device.Conclusion. A misplaced Essure device should be considered in the differential diagnosis of chronic pelvic pain in women who had difficult placement of the device. In addition to demonstrating tubal occlusion, careful examination of the configuration of the Essure microinserts on HSG examination provides valuable information in patients with pelvic pain after Essure placement.


2008 ◽  
Vol 2008 ◽  
pp. 1-4 ◽  
Author(s):  
Viet Q. Tran ◽  
Timothy F. Lesser ◽  
Dennis H. Kim ◽  
Sherif R. Aboseif

For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64), all patients had aprosthesisthat was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10). There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.


Sign in / Sign up

Export Citation Format

Share Document