Health Implications: Trace Elements in Cancer

Author(s):  
Rafael Borrs Avi ◽  
Jos Rafael Lpez-Moya ◽  
Juan Pedro Navarro-Avio
Author(s):  
O. A Omotoso

Ogunpa River receives municipal and industrial waste discharge from its catchments and these have depleted the quality of the water. Hence, this research examines the preliminary environmental impacts and health implications of some trace elements in the water using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) laboratory technique. Average values of Al, Ba, Fe, Mn, Ni and Pb are above the recommended limits of WHO. The CF showed that the trace elements varied from considerable contamination factor to very high contamination factor and the degree of contamination varied from 1023 to 11640. The hazard quotient computed for the adults is generally less than unity except Pb that has average value of 1.27. In children, the computed hazard quotient on the average ranges from 0.000572 to 4.04. Al, As, Ba, Cr, Cu, Ni, Zn and Cd have their average values less than unity respectively, while Fe, Mn and Pb has their average values greater than one. The Hazard Index (HI) in adults and children are greater than one. Carcinogenic risk assessment was computed for Cr, Pb and Cd which was greater than 10-6 in children and adult. Only Cd in adult was less than the prescribed limit of 10-6. Effort should be made to checkmate indiscriminate dumping of refuse and sewages into the water body as these could serve as pollutants to other adjourning rivers and main water bodies. In conclusion, the water is not fit for domestic, agricultural and probably industrial uses because of its health implications on consumption


2020 ◽  
Vol 221 ◽  
pp. 105383 ◽  
Author(s):  
Alexandra Lischka ◽  
Chris J. Pook ◽  
Jennifer L. Pannell ◽  
Heather E. Braid ◽  
Sally Gaw ◽  
...  

2009 ◽  
Vol 22 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Sara Barrento ◽  
António Marques ◽  
Bárbara Teixeira ◽  
Patrícia Anacleto ◽  
Maria Luísa Carvalho ◽  
...  

2019 ◽  
Vol 10 (4) ◽  
pp. 1347-1356 ◽  
Author(s):  
K.G. Koukoulakis ◽  
E. Chrysohou ◽  
P.G. Kanellopoulos ◽  
S. Karavoltsos ◽  
G. Katsouras ◽  
...  

Author(s):  
O.T. Woo ◽  
G.J.C. Carpenter

To study the influence of trace elements on the corrosion and hydrogen ingress in Zr-2.5 Nb pressure tube material, buttons of this alloy containing up to 0.83 at% Fe were made by arc-melting. The buttons were then annealed at 973 K for three days, furnace cooled, followed by ≈80% cold-rolling. The microstructure of cold-worked Zr-2.5 at% Nb-0.83 at% Fe (Fig. 1) contained both β-Zr and intermetallic precipitates in the α-Zr grains. The particles were 0.1 to 0.7 μm in size, with shapes ranging from spherical to ellipsoidal and often contained faults. β-Zr appeared either roughly spherical or as irregular elongated patches, often extending to several micrometres.The composition of the intermetallic particles seen in Fig. 1 was determined using Van Cappellen’s extrapolation technique for energy dispersive X-ray analysis of thin metal foils. The method was employed to avoid corrections for absorption and fluorescence via the Cliff-Lorimer equation: CA/CB = kAB · IA/IB, where CA and CB are the concentrations by weight of the elements A and B, and IA and IB are the X-ray intensities; kAB is a proportionality factor.


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


1979 ◽  
Vol 7 (6) ◽  
pp. 1330-1331
Author(s):  
E. D. WILLS

Sign in / Sign up

Export Citation Format

Share Document