scholarly journals Single‐center experience of ultra‐high‐density mapping guided catheter ablation of focal atrial tachycardia

2022 ◽  
Author(s):  
Antonia Kellnar ◽  
Stephanie Fichtner ◽  
Michael Mehr ◽  
Thomas Czermak ◽  
Moritz F. Sinner ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
C Jungen ◽  
R Akbulak ◽  
A Kahle ◽  
C Eickholt ◽  
B Schaeffer ◽  
...  

Abstract Background High-density mapping (HDM) has been found to precisely identify the practical isthmus of scar-related atrial tachycardia (AT) circuits. Since practical isthmuses have been found to be shorter than the usual anatomical isthmuses targeted ablation has been proposed. However, outcome data are sparse. Here we describe HDM-guided catheter ablation by targeting the practical isthmus in patients with scar-related ATs. Methods and results In 250 consecutive patients with scar-related ATs HDM-guided catheter ablation with the support of a 64-electrode mini-basket catheter has been performed. Most patients underwent a prior catheter ablation (98%) while 13% had a prior cardiac valve surgery and 6% an underlying congenital heart disease. A total of 355 ATs occurred in the index procedure, of which 64% had a macro-, 26% a micro-reentry and 10% a focal mechanism. The ATs had a mean cycle length of 304±4.3 ms and in 237 patients (95%) an acute termination into sinus rhythm was achieved. They were mainly located in the left atrium (72%) but also in the right atrium (25%), bi-atrially (5%) or in the CS (3%) (see figure). Targeting the practical isthmus revealed arrhythmia freedom in 53% of patients after a single procedure during a mid-term follow-up (median 489 days, range 95–1407 days). Freedom from any arrhythmia could be achieved in 74% of patients after multiple procedures and in 93% of patients after multiple procedures and optimal clinical therapy, including pharmaceutical or electrical cardioversion. Conclusions HDM-guided catheter ablation of the practical isthmus in patients with scar-related ATs leads to a high acute success rate. Nevertheless, multiple procedures are necessary in a relevant number of patients resulting in a low recurrence rate. Funding Acknowledgement Type of funding source: None


2020 ◽  
Author(s):  
Fares-Alexander Alken ◽  
Shaojie Chen ◽  
Mustafa Masjedi ◽  
Helmut Pürerfellner ◽  
Philippe Maury ◽  
...  

Aim: Ultra-high-density mapping (HDM) is increasingly used for guidance of catheter ablation in cardiac arrhythmias. While initial results are promising, a systematic evaluation of long-term outcome has not been performed so far. Methods: A systematic review and meta-analysis was conducted on studies investigating long-term outcome after Rhythmia HDM-guided atrial fibrillation (AF) or atrial tachycardia catheter ablation. Results: Beyond multiple studies providing novel insights into arrhythmia mechanisms, follow-up data from 17 studies analyzing Rhythmia HDM-guided ablation (1768 patients, 49% with previous ablation) were investigated. Cumulative acute success was 100/90.2%, while 12 months long-term pooled success displayed at 71.6/71.2% (AF/atrial tachycardia). Prospective data are limited, showing similar outcome between HDM-guided and conventional AF ablation. Conclusion: Acute results of HDM-guided catheter ablation are promising, while long-term success is challenged by complex arrhythmogenic substrates. Prospective randomized trials investigating different HDM-guided ablation strategies are warranted and underway.


2005 ◽  
Vol 46 (11) ◽  
pp. 2088-2099 ◽  
Author(s):  
Prashanthan Sanders ◽  
Mélèze Hocini ◽  
Pierre Jaïs ◽  
Li-Fern Hsu ◽  
Yoshihide Takahashi ◽  
...  

2020 ◽  
Vol 31 (10) ◽  
pp. 2645-2652 ◽  
Author(s):  
Christiane Jungen ◽  
Ruken Akbulak ◽  
Ann‐Kathrin Kahle ◽  
Christian Eickholt ◽  
Benjamin Schaeffer ◽  
...  

2011 ◽  
Vol 3 (1) ◽  
pp. 80
Author(s):  
Alexander Feldman ◽  
Jonathan M Kalman ◽  
◽  

Focal atrial tachycardia (AT) is a relatively uncommon cause of supraventricular tachycardia, but when present is frequently difficult to treat medically. Atrial tachycardias tend to originate from anatomically determined atrial sites. The P-wave morphology on surface electrocardiogram (ECG) together with more sophisticated contemporary mapping techniques facilitates precise localisation and ablation of these ectopic foci. Catheter ablation of focal AT is associated with high long-term success and may be viewed as a primary treatment strategy in symptomatic patients.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
C Cataldi ◽  
M Andronache ◽  
R Eschalier ◽  
F Jean ◽  
R Bosle ◽  
...  

Abstract Background The biatrial trans-septal approach (BTSa) ameliorates mitral valve (MV) exposure in difficult cases when routine left atriotomy doesnt"t allow it. Main steps are an oblique incision on the right atrium (RA), reaching medially the right pulmonary veins (PV), a septal incision from the fossa ovalis, extended up to reach the first incision, then on the left atrium (LA). Purpose We aim to study the arrhythmic burden in this post-surgical context, focusing on atrial tachycardia (AT), to investigate the complexity of several possible circuits. Methods All patients (>18yo) with previous MV surgery via BTSa for MV repair or replacement, who underwent ablation of AT from January 2017 to September 2019, were enrolled. Patients ablated for persistent or paroxysmal AF, or with AF during the index procedure were excluded. Patients with associated surgery on other valves or congenital defects, coronary, surgical or percutaneous rhythm interventions weren’t excluded. Electroanatomical mapping was created using 2 different high-density mapping system. Substrate and activation map and radio-frequency (RF) ablation (25-50W, Ablation Index target 400) were realized. Cartographies were analysed to evaluate AT re-entry circuit, critical isthmus (CI) location and characterization, atrial vulnerability. Procedural outcomes (AT termination, sinus rhythm (SR) restoration, anti-arrhythmic drugs (AAD) withdrawal), and peri-procedural complications were also evaluated. Results We enrolled 49 patients (median age 57 ± 15), finding a maximum of 5 AT per procedure (2 ± 1). A total of 112 AT were mapped: the majority (72%) were persistent AT, 8,2% common atrial flutter. Cycle length was 314 ± 74 msec, with proximal-distal activation of coronary sinus (78%). A multiple re-entry circuit was observed in 70% of index AT. We identified 152 critical isthmus (maximum 5 per procedure). Only 27,9% of our patients had a single CI; CTI was the most frequent one (n = 37), envolved in 33% of all AT, while BTS scars altogether were envolved in 65% AT. A complete AT circuit was mapped in the RA, the LA and both atria in respectively 49%, 11,5% and 39%AT. The distribution of CIs is shown in figure 1. Biatrial and left AT leads to superior procedure, RF and fluoroscopy duration (p <0,05). SR was restored in 93,4%of patients, requiring a DC shock in 4 cases. Immediate AAD withdrawal was achieved after 41%procedures. No pericardial, oesophageal, vascular or phrenic complication occurred. 4 pace-maker implantations were realized because of 3 interatrial, 2 AV block and a sinus node dysfunction. Conclusions AT occurring after a BTSa have a high prevalence of multiple re-entry circuits with multiple critical isthmus. Ablation in this context is feasible and safe but often requires a left atrial access. Mapping of both atria should be considered to identify critical isthmus and tailored ablation strategy. Abstract Figure 1. Critical Isthmus Distribution


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
L Fiedler ◽  
F Roithinger ◽  
I Roca ◽  
F Lorgat ◽  
A Roux ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott Background 3D mapping systems are pivotal to identify low voltage areas and to define ablation strategies. In this context, high-density multipolar mapping catheters with varying electrode configurations are used for accurate myocardial substrate definition. High density mapping using a grid shaped catheter allows for use of simultaneous analysis of adjacent orthogonal bipolar signals that may assist in more accurate substrate characterization and ablation strategy decisions. Purpose This was a prospective, multicenter observational study to characterize the utility of electroanatomical mapping with a high density grid-style mapping catheter (HD Grid) in subjects undergoing catheter ablation for persistent atrial fibrillation (PersAF) or ventricular tachycardia (VT) in real-world clinical settings. Methods Mapping was performed with the HD Grid catheter to generate high-density maps of cardiac chambers in order to assess the potential influence of the simultaneous orthogonal bipole configuration on PersAF and VT ablation strategies. Differences in substrate identification between simultaneous orthogonal bipole configuration and standard along-the-spline electrode configuration, and potential effects on ablation strategies were investigated. Results During the study period (January 2019 through April 2020), 367 subjects underwent catheter ablation for PersAF (N = 333, average age 64.1yr, 75% male) or VT (N = 34, average age = 64.3yr, 85.3% male). In total, 494 maps were generated to treat patients undergoing PersAF ablation and 57 to treat patients undergoing VT ablation. Compared to standard along-the-spline configuration, mapping with the simultaneous orthogonal bipole configuration showed differences in 57.8% (178/308) of maps generated, with the greatest difference noticed in surface area of low voltage (62.9%) and location of low voltage (55.6%). In comparisons performed live during the procedure (n = 50), simultaneous orthogonal bipole configuration assisted in identification of ablation targets in 70.0% of cases, changing the ablation strategy compared to that identified with along-the-spline configuration in 34.3%. In comparisons performed retrospectively after the procedure (n = 258), the ablation strategy identified with simultaneous orthogonal bipole configuration differed from along-the-spline configuration in 21.7% of maps. Even compared to a higher-density electrode configuration using all-bipoles rather than along-the-spline bipoles, simultaneous orthogonal bipole configuration identified differences in 57.1% of maps. Conclusion The HD grid catheter combined with simultaneous orthogonal bipole configuration can define myocardial substrate more accurately compared to standard along-the-spline configuration. The difference in substrate identification has potential impact on ablation strategy. Further clinical trials are needed to elucidate the role of orthogonal bipole configuration mapping and improved ablation success rates.


Sign in / Sign up

Export Citation Format

Share Document