Determination of α-hydroxy acids and their enantiomers in fruit juices by ligand exchange CE with a dual central metal ion system

2013 ◽  
Vol 34 (9-10) ◽  
pp. 1327-1333 ◽  
Author(s):  
Shuji Kodama ◽  
Sen-ichi Aizawa ◽  
Atsushi Taga ◽  
Atsushi Yamamoto ◽  
Yoshitaka Honda ◽  
...  
2012 ◽  
Vol 33 (18) ◽  
pp. 2920-2924 ◽  
Author(s):  
Shuji Kodama ◽  
Atsushi Yamamoto ◽  
Sen-ichi Aizawa ◽  
Yoshitaka Honda ◽  
Kentaro Suzuki ◽  
...  

Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1800
Author(s):  
Yuanqi Gui ◽  
Baian Ji ◽  
Gaoyi Yi ◽  
Xiuju Li ◽  
Kailian Zhang ◽  
...  

Herein, a novel L-arginine (L-Arg)-modified polydopamine (PDA)-coated capillary (PDA/L-Arg@capillary) was firstly fabricated via the basic amino-acid-induced PDA co-deposition strategy and employed to constitute a new chiral ligand exchange capillary electrochromatography (CLE-CEC) method for the high-performance enantioseparation of D,L-amino acids (D,L-AAs) with L-Arg as the immobilized chiral ligand coordinating with the central metal ion Zn(II) as running buffer. Assisted by hydrothermal treatment, the robust immobilization of L-Arg on the capillary inner wall could be facilely achieved within 1 h, prominently improving the synthesis efficiency and simplifying the preparation procedure. The successful preparation of PDA/L-Arg coatings in the capillary was systematically characterized and confirmed using several methods. In comparison with bare and PDA-functionalized capillaries, the enantioseparation capability of the presented CLE-CEC system was significantly enhanced. Eight D,L-AAs were completely separated and three pairs were partially separated under the optimal conditions. The prepared PDA/L-Arg@capillary showed good repeatability and stability. The potential mechanism of the greatly enhanced enantioseparation performance obtained by PDA/L-Arg@capillary was also explored. Moreover, the proposed method was further utilized for studying the enzyme kinetics of L-glutamic dehydrogenase, exhibiting its promising prospects in enzyme assays and other related applications.


2009 ◽  
Vol 74 (10) ◽  
pp. 1543-1557 ◽  
Author(s):  
Herman P. Van Leeuwen ◽  
Raewyn M. Town

The degree of (de)protonation of aqueous metal species has significant consequences for the kinetics of complex formation/dissociation. All protonated forms of both the ligand and the hydrated central metal ion contribute to the rate of complex formation to an extent weighted by the pertaining outer-sphere stabilities. Likewise, the lifetime of the uncomplexed metal is determined by all the various protonated ligand species. Therefore, the interfacial reaction layer thickness, μ, and the ensuing kinetic flux, Jkin, are more involved than in the conventional case. All inner-sphere complexes contribute to the overall rate of dissociation, as weighted by their respective rate constants for dissociation, kd. The presence of inner-sphere deprotonated H2O, or of outer-sphere protonated ligand, generally has a great impact on kd of the inner-sphere complex. Consequently, the overall flux can be dominated by a species that is a minor component of the bulk speciation. The concepts are shown to provide a good description of experimental stripping chronopotentiometric data for several protonated metal–ligand systems.


Biosensors ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 153
Author(s):  
Georgios Koukouvinos ◽  
Chrysoula-Evangelia Karachaliou ◽  
Ioannis Raptis ◽  
Panagiota Petrou ◽  
Evangelia Livaniou ◽  
...  

Carbendazim is a systemic benzimidazole-type fungicide with broad-spectrum activity against fungi that undermine food products safety and quality. Despite its effectiveness, carbendazim constitutes a major environmental pollutant, being hazardous to both humans and animals. Therefore, fast and reliable determination of carbendazim levels in water, soil, and food samples is of high importance for both food industry and public health. Herein, an optical biosensor based on white light reflectance spectroscopy (WLRS) for fast and sensitive determination of carbendazim in fruit juices is presented. The transducer is a Si/SiO2 chip functionalized with a benzimidazole conjugate, and determination is based on a competitive immunoassay format. Thus, for the assay, a mixture of an in-house developed rabbit polyclonal anti-carbendazim antibody with the standards or samples is pumped over the chip, followed by biotinylated secondary antibody and streptavidin. The WLRS platform allows for real-time monitoring of biomolecular interactions carried out onto the Si/SiO2 chip by transforming the shift in the reflected interference spectrum caused by the immunoreaction to effective biomolecular adlayer thickness. The sensor is able to detect 20 ng/mL of carbendazim in fruit juices with high accuracy and precision (intra- and inter-assay CVs ≤ 6.9% and ≤9.4%, respectively) in less than 30 min, applying a simple sample treatment that alleviates any “matrix-effect” on the assay results and a 60 min preincubation step for improving assay sensitivity. Excellent analytical characteristics and short analysis time along with its small size render the proposed WLRS immunosensor ideal for future on-the-spot determination of carbendazim in food and environmental samples.


Author(s):  
Monika Gorska ◽  
Pawel Pohl

Atmospheric pressure glow discharge (APGD) microplasma, sustained between a flowing liquid cathode (FLC) and a tungsten anode, was applied for the determination of Ca, K, Mg, and Na in fruit juices with a simplified sample preparation procedure.


2013 ◽  
Vol 97 ◽  
pp. 60-66 ◽  
Author(s):  
Er-Yu Chen ◽  
Ying-Chun Liu ◽  
Tian-Yang Sun ◽  
Qi Wang ◽  
Li-Jun Liang

Sign in / Sign up

Export Citation Format

Share Document