Ionic liquid-based microwave-assisted extraction for the determination of flavonoid glycosides in pigeon pea leaves by high-performance liquid chromatography-diode array detector with pentafluorophenyl column

2012 ◽  
Vol 35 (21) ◽  
pp. 2875-2883 ◽  
Author(s):  
Wei Wei ◽  
Yu-jie Fu ◽  
Yuan-gang Zu ◽  
Wei Wang ◽  
Meng Luo ◽  
...  
Marine Drugs ◽  
2021 ◽  
Vol 19 (6) ◽  
pp. 321
Author(s):  
Maria Orfanoudaki ◽  
Anja Hartmann ◽  
Julia Mayr ◽  
Félix L. Figueroa ◽  
Julia Vega ◽  
...  

This study presents the validation of a high-performance liquid chromatography diode array detector (HPLC-DAD) method for the determination of different mycosporine-like amino acids (MAAs) in the red alga Bostrychia scorpioides. The investigated MAAs, named bostrychines, have only been found in this specific species so far. The developed HPLC-DAD method was successfully applied for the quantification of the major MAAs in Bostrychia scorpioides extracts, collected from four different countries in Europe showing only minor differences between the investigated samples. In the past, several Bostrychia spp. have been reported to include cryptic species, and in some cases such as B. calliptera, B. simpliciuscula, and B. moritziana, the polyphyly was supported by differences in their MAA composition. The uniformity in the MAA composition of the investigated B. scorpioides samples is in agreement with the reported monophyly of this Bostrychia sp.


2009 ◽  
Vol 92 (2) ◽  
pp. 680-688 ◽  
Author(s):  
Pei Chen ◽  
Renata Atkinson ◽  
Wayne R Wolf

Abstract The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS) for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 m, 250 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100 A (0.1 formic acid in water), a linear gradient to 50 A and 50 B (0.1 formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLD/MS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.


Sign in / Sign up

Export Citation Format

Share Document