Intensity modulated operating mode of the rotating gamma system

2018 ◽  
Vol 45 (5) ◽  
pp. 2289-2298
Author(s):  
Bishwambhar Sengupta ◽  
Laszlo Gulyas ◽  
Donald Medlin ◽  
Tibor Koroknai ◽  
David Takacs ◽  
...  

Author(s):  
L. Gandolfi ◽  
J. Reiffel

Calculations have been performed on the contrast obtainable, using the Scanning Transmission Electron Microscope, in the observation of thick specimens. Recent research indicates a revival of an earlier interest in the observation of thin specimens with the view of comparing the attainable contrast using both types of specimens.Potential for biological applications of scanning transmission electron microscopy has led to a proliferation of the literature concerning specimen preparation methods and the controversy over “to stain or not to stain” in combination with the use of the dark field operating mode and the same choice of technique using bright field mode of operation has not yet been resolved.





2020 ◽  
pp. 28-33
Author(s):  
A. Yu. Dunaev ◽  
A. S. Baturin ◽  
V. N. Krutikov ◽  
S. P. Morozova

An improved monochromatic radiant source with spectral bandwidth of 4 nm based on supercontinuum laser and a double monochromator was included in absolute cryogenic radiometer-based facility to improve the accuracy of spectral responsivity measurement in the range 0.9–1.6 μm. The developed feedback system ensures stabilization of monochromatic radiant power with standard deviation up to 0.025 %. Radiant power that proceeds detector under test or absolute cryogenic radiometer varies from 0.1 to 1.5 mW in dependence of wavelength. The spectral power distribution of its monochromatic source for various operating mode is presented.



2018 ◽  
pp. 155-162 ◽  
Author(s):  
Sergei S. Kapitonov ◽  
Anastasia V. Kapitonova ◽  
Sergei Yu. Grigorovich ◽  
Sergei A. Medvedev ◽  
Taher Sobhy

In the article, the electrical and thermal processes in the LED lamp with varied parameters are investigated. Voltage and current measurements on all LEDs of the luminaire are carried out in the nominal operating mode. The power allocated to each LED is determined. The calculation of the LED crystal temperature was carried out using the developed thermal LED model based on the results of the measurements and by using “Multisim” program. It has been established that the temperature of the crystals of individual LEDs in the luminaire differ significantly, which leads to unfavourable thermal conditions for them and an increased likelihood of premature failure.



2008 ◽  
Author(s):  
Norie Matsubara ◽  
Tomohiko Ogata ◽  
Takanori Mitani ◽  
Shinji Munetoh ◽  
Teruaki Motooka


2015 ◽  
Vol 11 (3) ◽  
pp. 3146-3155
Author(s):  
Luhua Wang

Purpose: To evaluate the usefulness of helical tomotherapy (HT) in the treatment of advanced esophageal cancer (EC) and compare target homogeneity, conformity and normal tissue doses between HT and fixed-field intensity-modulated radiotherapy (ff-IMRT).Methods: In all, 23 patients with cT3-4N0-1M0-1a thoracic EC (upper esophagus, 9 patients; middle esophagus, 6; distal esophagus, 6 and esophagogastric junction, 2) who were treated with ff-IMRT (60 Gy in 30 fractions) were re-planned for HT and ff-IMRT with the same clinical require­ments. Comparisons were performed using the Wilcoxon matched-pair signed-rank test.Results: Compared with ff-IMRT, HT significantly reduced the homogeneity index for thoracic, upper, middle and distal ECs by 38%, 31%, 36% and 33%, respectively (P < 0.05). The conformity index was increased by HT for thoracic, upper and middle ECs by 9%, 9% and 18%, respectively (P < 0.05). Target coverage was improved by 1% with HT (P < 0.05). The mean lung dose was significantly reduced by HT for thoracic and upper ECs (P < 0.05). The V20 (volume receiving at least 20 Gy) and higher dose volumes of the lungs were decreased by HT in all cases, but the differences were significant for thoracic, upper and distal ECs (P < 0.05), with reductions of 2.1%, 3.1% and 2.2%, respectively. HT resulted in a larger lung V5 for thoracic, upper, middle and distal ECs, with increases of 3.5%, 1.5%, 7.2% and 3.2%, respectively. Heart sparing was significantly better with HT than with ff-IMRT in terms of the V30 and V40 for thoracic, upper, middle and distal ECs (P < 0.05).Conclusions: Compared to ff-IMRT, HT provides superior target coverage, conformity and homogeneity, with reduced the volume of high doses to the lungs and heart for advanced EC. HT may be a treatment option for advanced EC, especially upper EC.



2018 ◽  
Vol 9 ◽  
pp. 193-201
Author(s):  
I.U. Prokopenko ◽  
◽  
S.A. Denisov ◽  
A.S. Morkovin ◽  
D.K. Nesterov ◽  
...  


2019 ◽  
Vol 85 (7) ◽  
pp. 16-21
Author(s):  
Liliya R. Mubarakova ◽  
German K. Budnikov

Sultones are cyclic esters of hydroxysulfonic acids, which are formed in the process of sulfonation of α-olefins with sulfur trioxide gas. More stable sultones may be present in the final product — an anionic surfactant — sodium α-olefin sulfonate (AOC-Na). AOC-Na is widely used in the production of household chemicals and cosmetic products, including liquid dishwashing detergents. Sultones are strong skin sensitizers, their level in AOC-Na should be strictly controlled and not exceed 5 ppm. Operational and strict control of the sultone content upon AOC-Na production allows timely adjustment at the stage of hydrolysis, which leads to a more complete disclosure of the sultone cycle with the formation of the corresponding olefin sulfonates and hydroxyalkanesulfonates. We propose a method for determining δ-hexadecansultone in liquid dishwashing detergents and sodium α-olefinsulfonates obtained on the basis of α-olefins of C14 – C16 fractions using GC/MS, which provides shortening of sample preparation and keeps the sensitivity with a detection limit of 0.02 mg/kg. The effect of various weakly polar and non-polar organic solvents used for Sultone extraction from AOC-Na and liquid detergent on liquid extraction based on the dispersion of the extractant in an alcohol/water phase is studied. When selecting the solvent we have shown that the use of diethyl ether provided the best extraction of the analyte. Determination of the analyte extraction recovery was performed using the reaction of hydrolysis of the extracted mixture. We specified the operating mode of the device which provided complete separation of the components of the analyzed compounds including the samples of liquid detergent for dishes being a multicomponent mixture of complex composition.



Sign in / Sign up

Export Citation Format

Share Document