Innovative Monochromatic X‐ray Source for High Quality and Low Dose Medical Imaging

2020 ◽  
Author(s):  
Eric Silver ◽  
Seth Shulman ◽  
Madan M. Rehani
Keyword(s):  
Low Dose ◽  
1998 ◽  
Vol 43 (10) ◽  
pp. 2845-2852 ◽  
Author(s):  
F Arfelli ◽  
M Assante ◽  
V Bonvicini ◽  
A Bravin ◽  
G Cantatore ◽  
...  

2007 ◽  
Vol 34 (12) ◽  
pp. 4612-4625 ◽  
Author(s):  
C. D. Arvanitis ◽  
S. E. Bohndiek ◽  
G. Royle ◽  
A. Blue ◽  
H. X. Liang ◽  
...  

Author(s):  
T. Oikawa ◽  
N. Mori ◽  
T. Katoh ◽  
Y. Harada ◽  
J. Miyahara ◽  
...  

The “Imaging Plate”(IP) is a highly sensitive image recording plate for X-ray radiography. It has been ascertained that the IP has superior properties and high practicability as an image recording material in a TEM. The sensitivity, one of the properties, is about 3 orders higher than that of conventional photo film. The IP is expected to be applied to low dose techniques. In this paper, an estimation of the quantum noise on the TEM image which appears in case of low electron dose on the IP is reported.In this experiment, the JEM-2000FX TEM and an IP having the same size as photo film were used.Figure 1 shows the schematic diagram of the total system including the TEM used in this experiment. In the reader, He-Ne laser light is scanned across the IP, then blue light is emitted from the IP.


Author(s):  
John A. Hunt ◽  
Richard D. Leapman ◽  
David B. Williams

Interactive MASI involves controlling the raster of a STEM or SEM probe to areas predefined byan integration mask which is formed by image processing, drawing or selecting regions manually. EELS, x-ray, or other spectra are then acquired while the probe is scanning over the areas defined by the integration mask. The technique has several advantages: (1) Low-dose spectra can be acquired by averaging the dose over a great many similar features. (2) MASI can eliminate the risks of spatial under- or over-sampling of multiple, complicated, and irregularly shaped objects. (3) MASI is an extremely rapid and convenient way to record spectra for routine analysis. The technique is performed as follows:Acquire reference imageOptionally blank beam for beam-sensitive specimensUse image processor to select integration mask from reference imageCalculate scanning path for probeUnblank probe (if blanked)Correct for specimen drift since reference image acquisition


Author(s):  
T.W. Jeng ◽  
W. Chiu

With the advances in preparing biological materials in a thin and highly ordered form, and in maintaining them hydrated under vacuum, electron crystallography has become an important tool for biological structure investigation at high resolution (1,2). However, the electron radiation damage would limit the capability of recording reflections with low intensities in an electron diffraction pattern. It has been demonstrated that the use of a low temperature stage can reduce the radiation damage effect and that one can expose the specimen with a higher dose in order to increase the signal contrast (3). A further improvement can be made by selecting a proper photographic emulsion. The primary factors in evaluating the suitability of photographic emulsion for recording low dose diffraction patterns are speed, fog level, electron response at low electron exposure, linearity, and usable range of exposure. We have compared these factors with three photographic emulsions including Kodak electron microscopic plate (EMP), Industrex AA x-ray film (AA x-ray) and Kodak nuclear track film (NTB3).


2020 ◽  
Vol 64 (2) ◽  
pp. 20503-1-20503-5
Author(s):  
Faiz Wali ◽  
Shenghao Wang ◽  
Ji Li ◽  
Jianheng Huang ◽  
Yaohu Lei ◽  
...  

Abstract Grating-based x-ray phase-contrast imaging has the potential to enhance image quality and provide inner structure details non-destructively. In this work, using grating-based x-ray phase-contrast imaging system and employing integrating-bucket method, the quantitative expressions of signal-to-noise ratios due to photon statistics and mechanical error are analyzed in detail. Photon statistical noise and mechanical error are the main sources affecting the image noise in x-ray grating interferometry. Integrating-bucket method is a new phase extraction method translated to x-ray grating interferometry; hence, its image quality analysis would be of great importance to get high-quality phase image. The authors’ conclusions provide an alternate method to get high-quality refraction signal using grating interferometer, and hence increases applicability of grating interferometry in preclinical and clinical usage.


Author(s):  
Koji INAKA ◽  
Saori ICHIMIZU ◽  
Izumi YOSHIZAKI ◽  
Kiyohito KIHIRA ◽  
Elena G. LAVRENKO ◽  
...  

A series of space experiments aboard the International Space Station (ISS) associated with high-quality Protein Crystal Growth (PCG) in microgravity conditions can be considered as a unique and one of the best examples of fruitful collaboration between Japanese and Russian scientists and engineers in space, which includes also other ISS International Partners. X-ray diffraction is still the most powerful tool to determine the protein three dimensional structure necessary for Structure based drug design (SBDD). The major purpose of the experiment is to grow high quality protein crystals in microgravity for X-ray diffraction on Earth. Within one and a half decade, Japan and Russia have established an efficient process over PCG in space to support latest developments over drug design and structural biology. One of the keys for success of the experiment lies in how precisely pre-launch preparations are made. Japanese party provides flight equipment for crystallization and ensures the required environment to support the experiment aboard of the ISS’s Kibo module, and also mainly takes part of the experiment ground support such as protein sample characterization, purification, crystallization screening, and solution optimization for microgravity experiment. Russian party is responsible for integration of the flight items equipped with proteins and precipitants on board Russian transportation space vehicles (Soyuz or Progress), for delivery them at the ISS, transfer to Kibo module, and returning the experiments’ results back on Earth aboard Soyuz manned capsule. Due to close cooperation of the parties and solid organizational structure, samples can be launched at the ISS every half a year if the ground preparation goes smoothly. The samples are crystallized using counter diffusion method at 20 degree C for 1–2.5 months. After samples return, the crystals are carefully taken out from the capillary, and frozen for X-ray diffraction at SPring8 facility in Japan. Extensive support of researchers from both countries is also a part of this process. The paper analyses details of the PCG experiment scheme, unique and reliable technology of its execution, and contains examples of the application. Key words: International Space Station, Protein crystals, Microgravity, International collaboration.


2021 ◽  
pp. 2004391
Author(s):  
Youbin Li ◽  
Mingyang Jiang ◽  
Zhiming Deng ◽  
Songjun Zeng ◽  
Jianhua Hao
Keyword(s):  
Low Dose ◽  
X Ray ◽  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


Sign in / Sign up

Export Citation Format

Share Document