Seismic Performance and Reinforcement of Japanese High-Rise Building HIGH-RISE BUILDING HIGH-RISE BUILDING s Facing Subduction Earthquake SUBDUCTION EARTHQUAKE SUBDUCTION EARTHQUAKE SUBDUCTION EARTHQUAKE SUBDUCTION EARTHQUAKE s: E-Defense E-DEFENSE E-DEFENSE Shake Table Test SHAKE TABLE TEST SHAKE TABLE TEST SHAKE TABLE TEST SHAKE TABLE TEST s

Author(s):  
Takuya Nagae ◽  
Takahito Inoue ◽  
Koichi Kajiwara ◽  
Masayoshi Nakashima
2012 ◽  
Vol 446-449 ◽  
pp. 3889-3893
Author(s):  
Bin Zhao ◽  
Juan He ◽  
Hui Gao ◽  
Xu Gang Chen

For many high-rising buildings, large local space is very useful for its special function needs, such as conference hall and hotel lobby. The shake table test results of a high-rising building with large local space show that the dynamic characteristics of such structure are complex and the torsional mode becomes the first mode, while the torsional responses under earthquake excitation, especially of the floor just above the large local space, are very remarkable. In this paper, the bidirectional Tuned Mass Damper (TMD) is employed for reducing the torsional vibration of such complex high-rise building structure. A reduced-scale model is design and constructed. A series of shake table tests are carried out and the test results indicate that the TMD system is very effective in torsional vibration control of structural system.


2012 ◽  
Vol 204-208 ◽  
pp. 2590-2594
Author(s):  
Bin Zhao ◽  
Juan He

In this research, a reduced scale model of the composite high-rise building with steel reinforced concrete column, steel beam and reinforced concrete core tube was designed and tested by using the shake table test technology. The acceleration and displacement of the model were measured during the tests. The cracking pattern and failure mechanism were illustrated. Above the shake table test, the finite element analysis of the test mode was carried out. The main effort of the numerical analysis was focused on the selection of the nonlinear models. Based on the experiment results and the strategy of considering nonlinear property of the beam-column joint and the short beam of the concrete core wall were proposed. It is proved that the proposed strategy is effective and economical for seismic behavior assessment of such composite high-rise building structure system.


2014 ◽  
Vol 580-583 ◽  
pp. 1551-1554
Author(s):  
Gen Tian Zhao ◽  
Xu Ting Kou

With the project case, the seismic performance of girder transfer floor member and the plate transfer floor member were discussed. Contrast calculation was carried out in girder transfer floor member and the plate transfer floor member with SATWE method to analyze its reasonable and unreasonable places. Based on overall structure calculation of a high rise building, the seismic design requirements for buildings applying thick transferring plate have been presented. The conclusion is that the seismic performance of girder transfer floor member is more advantageous and affordable, more convenient and more economical in ingredients.


2017 ◽  
Vol 12 (5) ◽  
pp. 868-881
Author(s):  
Yohsuke Kawamata ◽  
Manabu Nakayama ◽  
Ikuo Towhata ◽  
Susumu Yasuda ◽  
◽  
...  

Underground structures are generally considered to have high seismic performance and expected to play an important role as a base for reconstruction even after a destructive earthquake. Rigidity changing points, such as jointed and curved portions of underground structure, where localized deformation and stress is supposed to be generated, are ones of the most critical portions in terms of seismic performance of underground structure. Because the underground structure in a mega-city functions as a network, local damage could lead to fatal dysfunction. Accordingly, rigidity changing points and their surrounding area could significantly influence the resiliency of urban functions, and it is indispensable to evaluate their seismic performance and dynamic responses during earthquakes. The responses of rigidity changing points and their surrounding area to earthquakes have been tried evaluating by using large-scale numerical analyses, there is no case available where the responses have been measured in detail. For this reason, it is difficult to verify the validity of the results of such evaluations.In light of the above, the shake table test was conducted at E-Defense using a coupled specimen of soil and underground structures to obtain detailed data, especially on the localized responses around rigidity changing points during the earthquake. Based on the data obtained, the behavior of the underground structure with a curved portion at the time of an earthquake was analyzed comprehensively. As a result of the analysis on the test data, it is found that there is a strong correlation between the localized deformation of the curved portion of the tunnel and the displacement of the surrounding ground. In addition, it is necessary to conduct a three-dimensional seismic response analysis not only around the rigidity changing point but also in wider area.


2010 ◽  
Vol 163-167 ◽  
pp. 1281-1285
Author(s):  
Bin Wang ◽  
Huan Jun Jiang ◽  
Jian Bao Li ◽  
Wen Sheng Lu ◽  
Xi Lin Lu

The reinforced concrete (RC) frame-tube structure considered in the study has two towers with lapping transfer columns. The lapping transfer columns, considering aesthetic requirement in elevation, lead to a complex vertical force transfer system. The large irregularity in elevation, according to Chinese code, necessitates a detailed study. A 1/15-scaled model of the high-rise building was tested on a shaking table to evaluate its seismic performance. The model was subjected to earthquake inputs representing frequent, basic, rare, and extremly rare earthquakes. The results of shaking table test in terms of the global and local responses as well as the dynamic properties are presented. The tests demonstrate that the designed structural system satisfies the pre-defined performance objectives and the lapping transfer columns have good seismic peformance. To better control seismic damages of the building, some suggestions for improving the design of this structure are also put forward at last.


2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Haotian Zhang ◽  
Fuju Li ◽  
Ji Tai ◽  
Jun Zhou

In the high intensity areas, the application of interlayer spacing technology can achieve the unity of quality and seismic performance of high-rise buildings with enlarged base and multiple tower layers. Through the comparison and analysis of the structural schemes of an enlarged base multiple tower-layer high-rise building, the ultimate seismic isolation scheme was adopted, and its seismic response and seismic performance were analyzed and studied. The results show that the overall seismic isolation effect of the story isolation technique is good, which can greatly reduce the seismic response, and is an effective means to improve the seismic safety of the structure. Considering the structural characteristics of the project, the improvement of the economy and the quality of the building, the use of story isolation technique in the enlarged base multiple tower-layer structure in the high-intensity region is an optimal scheme. Finally, several key technical issues such as the combined seismic isolation scheme of the enlarged base story isolation technique and the additional bending moment of the isolator and the tensile device of the isolator were discussed, which can provide some references for similar engineering practices.


Sign in / Sign up

Export Citation Format

Share Document