Sacral Spine, Pelvis, and Pelvic Ring

2013 ◽  
pp. 387-398
Author(s):  
Megan Brady ◽  
Stephen Tolhurst ◽  
Timothy Moore
Keyword(s):  
2018 ◽  
Vol 23 (4) ◽  
pp. 9-10
Author(s):  
James Talmage ◽  
Jay Blaisdell

Abstract Pelvic fractures are relatively uncommon, and in workers’ compensation most pelvic fractures are the result of an acute, high-impact event such as a fall from a roof or an automobile collision. A person with osteoporosis may sustain a pelvic fracture from a lower-impact injury such as a minor fall. Further, major parts of the bladder, bowel, reproductive organs, nerves, and blood vessels pass through the pelvic ring, and traumatic pelvic fractures that result from a high-impact event often coincide with damaged organs, significant bleeding, and sensory and motor dysfunction. Following are the steps in the rating process: 1) assign the diagnosis and impairment class for the pelvis; 2) assign the functional history, physical examination, and clinical studies grade modifiers; and 3) apply the net adjustment formula. Because pelvic fractures are so uncommon, raters may be less familiar with the rating process for these types of injuries. The diagnosis-based methodology for rating pelvic fractures is consistent with the process used to rate other musculoskeletal impairments. Evaluators must base the rating on reliable data when the patient is at maximum medical impairment and must assess possible impairment from concomitant injuries.


Author(s):  
Giuseppe Rovere ◽  
Andrea Perna ◽  
Luigi Meccariello ◽  
Domenico De Mauro ◽  
Alessandro Smimmo ◽  
...  

Abstract Introduction Pelvic ring injuries, frequently caused by high energy trauma, are associated with high rates of morbidity and mortality (5–33%), often due to significant blood loss and disruption of the lumbosacral plexus, genitourinary system, and gastrointestinal system. The aim of the present study is to perform a systematic literature review on male and female sexual dysfunctions related to traumatic lesions of the pelvic ring. Methods Scopus, Cochrane Library MEDLINE via PubMed, and Embase were searched using the keywords: “Pelvic fracture,” “Pelvic Ring Fracture,” “Pelvic Ring Trauma,” “Pelvic Ring injury,” “Sexual dysfunction,” “Erectile dysfunction,” “dyspareunia,” and their MeSH terms in any possible combination. The following questions were formulated according to the PICO (population (P), intervention (I), comparison (C), and outcome (O)) scheme: Do patients suffering from pelvic fracture (P) report worse clinical outcomes (C), in terms of sexual function (O), when urological injury occurs (I)? Is the sexual function (O) influenced by the type of fracture (I)? Results After screening 268 articles by title and abstract, 77 were considered eligible for the full-text analysis. Finally 17 studies that met inclusion criteria were included in the review. Overall, 1364 patients (902 males and 462 females, M/F ratio: 1.9) suffering from pelvic fractures were collected. Discussion Pelvic fractures represent challenging entities, often concomitant with systemic injuries and subsequent morbidity. Anatomical consideration, etiology, correlation between sexual dysfunction and genitourinary lesions, or pelvic fracture type were investigated. Conclusion There are evidences in the literature that the gravity and frequency of SD are related with the pelvic ring fracture type. In fact, patients with APC, VS (according Young-Burgess), or C (according Tile) fracture pattern reported higher incidence and gravity of SD. Only a week association could be found between GUI and incidence and gravity of SD, and relationship between surgical treatment and SD. Electrophysiological tests should be routinely used in patient suffering from SD after pelvic ring injuries.


Author(s):  
M. F. Hoffmann ◽  
E. Yilmaz ◽  
D. C. Norvel ◽  
T. A. Schildhauer

Abstract Purpose Instability of the posterior pelvic ring may be stabilized by lumbopelvic fixation. The optimal osseous corridor for iliac screw placement from the posterior superior iliac spine to the anterior inferior iliac spine requires multiple ap- and lateral-views with additional obturator-outlet and -inlet views. The purpose of this study was to determine if navigated iliac screw placement for lumbopelvic fixation influences surgical time, fluoroscopy time, radiation exposure, and complication rates. Methods Bilateral lumbopelvic fixation was performed in 63 patients. Implants were inserted as previously described by Schildhauer. A passive optoelectronic navigation system with surface matching on L4 was utilized for navigated iliac screw placement. To compare groups, demographics were assessed. Operative time, fluoroscopic time, and radiation were delineated. Results Conventional fluoroscopic imaging for lumbopelvic fixation was performed in 32 patients and 31 patients underwent the procedure with navigated iliac screw placement. No differences were found between the groups regarding demographics, comorbidities, or additional surgical procedures. Utilization of navigation led to fluoroscopy time reduction of more than 50% (3.2 vs. 8.6 min.; p < 0.001) resulting in reduced radiation (2004.5 vs. 5130.8 Gy*cm2; p < 0.001). Operative time was reduced in the navigation group (176.7 vs. 227.4 min; p = 0.002) despite the necessity of additional surface referencing. Conclusion For iliac screws, identifying the correct entry point and angle of implantation requires detailed anatomic knowledge and multiple radiographic views. In our study, additional navigation reduced operative time and fluoroscopy time resulting in a significant reduction of radiation exposure for patients and OR personnel.


Injury ◽  
2021 ◽  
Author(s):  
Michela Florio ◽  
Luigi Capasso ◽  
Alessandro Olivi ◽  
Carla Vitiello ◽  
Antonio Leone ◽  
...  

Author(s):  
Michiel Herteleer ◽  
Mehdi Boudissa ◽  
Alexander Hofmann ◽  
Daniel Wagner ◽  
Pol Maria Rommens

Abstract Introduction In fragility fractures of the pelvis (FFP), fractures of the posterior pelvic ring are nearly always combined with fractures of the anterior pelvic ring. When a surgical stabilization of the posterior pelvis is performed, a stabilization of the anterior pelvis is recommended as well. In this study, we aim at finding out whether conventional plate osteosynthesis is a valid option in patients with osteoporotic bone. Materials and methods We retrospectively reviewed medical charts and radiographs of all patients with a FFP, who underwent a plate osteosynthesis of the anterior pelvic ring between 2009 and 2019. Patient demographics, fracture characteristics, properties of the osteosynthesis, complications and revision surgeries were documented. Single plate osteosynthesis (SPO) at the pelvic brim was compared with double plate osteosynthesis (DPO) with one plate at the pelvic brim and one plate anteriorly. We hypothesized that the number and severity of screw loosening (SL) or plate breakage in DPO are lower than in SPO. Results 48 patients with a mean age of 76.8 years were reviewed. In 37 cases, SPO was performed, in 11 cases DPO. Eight out of 11 DPO were performed in patients with FFP type III or FFP type IV. We performed significantly more DPO when the instability was located at the level of the pubic symphysis (p = 0.025). More patients with a chronic FFP (surgery more than one month after diagnosis) were treated with DPO (p = 0.07). Infra-acetabular screws were more often inserted in DPO (p = 0.056). Screw loosening (SL) was seen in the superior plate in 45% of patients. There was no SL in the anterior plate. There was SL in 19 of 37 patients with SPO and in 3 of 11 patients with DPO (p = 0.16). SL was localized near to the pubic symphysis in 19 of 22 patients after SPO and in all three patients after DPO. There was no SL in DPO within the first month postoperatively. We performed revision osteosynthesis in six patients (6/48), all belonged to the SPO group (6/37). The presence of a bone defect, unilateral or bilateral anterior pelvic ring fracture, post-operative weight-bearing restrictions, osteosynthesis of the posterior pelvic ring, and the presence of infra- or supra-acetabular screws did not significantly influence screw loosening in SPO or DPO. Conclusion There is a high rate of SL in plate fixation of the anterior pelvic ring in FFP. In the vast majority, SL is located near to the pubic symphysis. DPO is associated with a lower rate of SL, less severe SL and a later onset of SL. Revision surgery is less likely in DPO. In FFP, we recommend DPO instead of SPO for fixation of fractures of the anterior pelvic ring, which are located in or near to the pubic symphysis.


Author(s):  
Manuel Sterneder ◽  
Patricia Lang ◽  
Hans-Joachim Riesner ◽  
Carsten Hackenbroch ◽  
Benedikt Friemert ◽  
...  

Abstract Background Fragility fractures of the pelvis (FFP) encompass two fracture entities: fracture after low-energy trauma and insufficiency fracture without trauma. It is unclear whether the two subgroups differ in terms of diagnosis and therapy. The aim of this retrospective study was to evaluate insufficiency fractures with regard to defined parameters and to compare specific parameters with the fractures after low-energy trauma. Patients and Methods In the period from 2008 to 2017, 203 patients with FFP were recorded at our clinic (Level 1 Trauma Centre DGU, SAV approval). Of these, 25 had an insufficiency fracture and 178 had a pelvic ring fracture after low-energy trauma. Epidemiological, diagnostic and therapeutic parameters were examined. Results There was a relative increase in the insufficiency fracture within the FFP (2008 – 2009: 5.0% vs. 2015 – 2017: 17.8%). In these patients, osteoporosis tended to be more pronounced than in patients after low-energy trauma (t-value: − 3.66 vs. − 3.13). The diagnosis of insufficiency fractures showed increased use of MRI and DECT (60.9% vs. 26.0%) and a high proportion of type IV fractures after FFP (40.0% vs. 7.9%). In terms of therapy, surgical treatment of the insufficiency fracture was sought more often (68,2% vs. 52,1%), with a tendency towards increased use of combined osteosynthesis procedures (14.3% vs. 7.6%). Conclusion We were able to show that as the number of cases increases, the insufficiency fracture becomes more important within FFP. If these patients tend to have more pronounced osteoporosis, particular attention should be paid to the diagnosis and adequate therapy of the osteoporosis, especially in the case of an insufficiency fracture. In addition to the increased diagnostic testing using MRI and DECT to detect oedema and the increased surgical therapy for this type of fracture, it is also noteworthy that the insufficiency fracture can cause higher-grade fractures after FFP.


2021 ◽  
Vol 12 ◽  
pp. 215145932098540
Author(s):  
Bailey R. Abernathy ◽  
Lisa K. Schroder ◽  
Deborah C. Bohn ◽  
Julie A. Switzer

Introduction: A need exists for improved care pathways for patients experiencing low-energy pelvic ring fractures. A review of the current literature was performed to understand the typical patient care and post-acute rehabilitation pathway within the US healthcare system. We also sought to summarize reported clinical outcomes worldwide. Significance: Low-energy pelvic ring fracture patients usually do not qualify for inpatient admission, yet they often require post-acute rehabilitative care. The Center for Medicare and Medicaid Services’ (CMS) 3-day rule is a barrier to obtaining financial coverage of this rehabilitative care. Results: Direct admission of some patients to post-acute care facilities has shown promise with decreased cost, improved patient outcomes, and increased patient satisfaction. Secondary fracture prevention programs may also improve outcomes for this patient population. Conclusions: Post-acute care innovation and secondary fracture prevention should be prioritized in the low-energy pelvic fragility fracture patient population. To demonstrate the effect and feasibility of these improved care pathways, further studies are necessary.