Seismic Response of Buildings Resting on Pile-Raft Foundation in Soft Soil

Author(s):  
S. Vinoda Krishna ◽  
B. R. Jayalekshmi
2016 ◽  
Vol 16 (08) ◽  
pp. 1550043 ◽  
Author(s):  
Aslan S. Hokmabadi ◽  
Behzad Fatahi

In selecting the type of foundation best suited for mid-rise buildings in high risk seismic zones, design engineers may consider that a shallow foundation, a pile foundation, or a pile-raft foundation can best carry the static and dynamic loads. However, different types of foundations behave differently during earthquakes, depending on the soil–structure interaction (SSI) where the properties of the in situ soil and type of foundation change the dynamic characteristics (natural frequency and damping) of the soil–foundation–structure system. In order to investigate the different characteristics of SSI and its influence on the seismic response of building frames, a 3D numerical model of a 15-storey full-scale (prototype) structure was simulated with four different types of foundations: (i) A fixed-based structure that excludes the SSI, (ii) a structure supported by a shallow foundation, (iii) a structure supported by a pile-raft foundation in soft soil and (iv) a structure supported by a floating (frictional) pile foundation in soft soil. Finite difference analyzes with FLAC3D were then conducted using real earthquake records that incorporated material (soil and superstructure) and geometric (uplifting, gapping and [Formula: see text] effects) nonlinearities. The 3D numerical modeling procedure had previously been verified against experimental shaking table tests conducted by the authors. The results are then presented and compared in terms of soil amplification, shear force distribution and rocking of the superstructure, including its lateral deformation and drift. The results showed that the type of foundation is a major contributor to the seismic response of buildings with SSI and should therefore be given careful consideration in order to ensure a safe and cost effective design.


1984 ◽  
Vol 19 (3) ◽  
pp. 369-380 ◽  
Author(s):  
Carl F. Neuss ◽  
Bruce F. Maison

2014 ◽  
Vol 695 ◽  
pp. 613-616
Author(s):  
Mohd Faiz Mohammad Zaki ◽  
Mohammad Fadzli Ramli ◽  
Afizah Ayob ◽  
Mohd Taftazani Ahmad

It is becoming a great challenge for civil engineers to design a foundation which able to minimize the effect of an earthquake. A major earthquake produces a strong ground motion in the subsoil and surface structures supported on the soil mass will be induced to move and absorb the dynamic forces. Seismic retrofit of existing foundations is an alternative. However, the modification of this existing foundation toward earthquake resistances raises issues which are far from being totally resolved. Innovative material such as EPS is widely accepted in structural engineering due to its characteristic to absorb the dynamic force effectively. This EPS material demonstrated the practicality and has been applied for geotechnical engineering for various reasons. Based on this, a research which is related to the application of EPS in mitigating the earthquake forces, particularly for raft foundations was conducted properly in this research. The various types and thickness of EPS located beneath the raft foundation and over the soft soil are studied. A finite element program is utilized to develop the computer simulation models. Based on the results, Expended Polystyrene (EPS) Geofoam, placed beneath the raft foundation is able to produces the minimum settlements when subjected to earthquake loading rather than raft foundation modeled without EPS and increasing the density of EPS will simultaneously decrease the settlement of a foundation.


Author(s):  
Wenai Shen ◽  
Zhentao Long ◽  
Heng Wang ◽  
Hongping Zhu

Abstract Tuned inerter dampers (TID) have been demonstrated as efficient energy dissipation devices for seismic response control. However, its potential capability for energy harvesting remains largely unexplored. Here, we present a theoretical analysis of the power of a structure-TID system subjected to earthquake ground motions. The analytical solutions of the average damping power of the system are derived for considering white noise base excitations and the Kanai-Tajimi earthquake model, respectively. Comparisons of the numerical results of a Monte Carlo simulation and the theoretical predictions verify the accuracy of the analytical solutions. Besides, we uncover the influence of the TID parameters on the damping power and output power of the system. The optimal frequency ratio of the TID for maximizing its output power slightly differs from that for seismic response control, and the former varies with site conditions. In contrast, both the damping power and output power are not sensitive to the damping ratio of the TID. For short-period structures, a small inertance-to-mass ratio (µ) of the TID is beneficial to maximize its output power, while seismic response control requires a large µ. For long-period structures, the damping power and output power are not sensitive to the µ. Generally, a structure-TID system on a soft soil site absorbs more energy from a given earthquake and is capable of harvesting more energy than that on a hard soil site. This study may help develop new strategies for self-powered control and monitoring in civil structures.


2020 ◽  
Vol 10 (23) ◽  
pp. 8357
Author(s):  
Ibrahim Oz ◽  
Sevket Murat Senel ◽  
Mehmet Palanci ◽  
Ali Kalkan

Reconnaissance studies performed after destructive earthquakes have shown that seismic performance of existing buildings, especially constructed on weak soils, is significantly low. This situation implies the negative effects of soil-structure interaction on the seismic performance of buildings. In order to investigate these effects, 40 existing buildings from Turkey were selected and nonlinear models were constructed by considering fixed-base and stiff, moderate and soft soil conditions. Buildings designed before and after Turkish Earthquake code of 1998 were grouped as old and new buildings, respectively. Different soil conditions classified according to shear wave velocities were reflected by using substructure method. Inelastic deformation demands were obtained by using nonlinear time history analysis and 20 real acceleration records selected from major earthquakes were used. The results have shown that soil-structure interaction, especially in soft soil cases, significantly affects the seismic response of old buildings. The most significant increase in drift demands occurred in first stories and the results corresponding to fixed-base, stiff and moderate cases are closer to each other with respect to soft soil cases. Distribution of results has indicated that effect of soil-structure interaction on the seismic performance of new buildings is limited with respect to old buildings.


Sign in / Sign up

Export Citation Format

Share Document