Effect of thread depth and thread pitch on the primary stability of miniscrews receiving a torque load

Author(s):  
Yushan Ye ◽  
Weimin Yi ◽  
Song Fan ◽  
Luodan Zhao ◽  
Yansong Yu ◽  
...  
F1000Research ◽  
2018 ◽  
Vol 7 ◽  
pp. 1898 ◽  
Author(s):  
Abdullah Saleh Almutairi ◽  
Maher Abdullatif Walid ◽  
Mohamed Ahmed Alkhodary

Background: It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact. Also, dental implants with deeper threads, and decreased thread pitch can increase initial bone implant anchorage. Methods: This study utilized 48 custom-made machined surface dental implants that were 13 mm long, with a major diameter of 4.5 mm and a minor diameter of 3.5 mm, a thread pitch of 1 mm, a thread depth of 0.5 mm, and a 4 mm long cutting flute at the apex.  The implants were divided into 4 groups, each group was made of 12 implants with a different thread design; V-shaped, trapezoid, buttress, and reverse buttress. The implants were inserted in 4-mm thick cancellous bone slices obtained from the head of Cow femur bone. The ostoetomies were prepared by conventional drilling and by OD drilling. Each inserted implant was then tested for primary stability using the Periotest. The Periotest values (PTVs) for the implant stability were tabulated and analyzed using a chi square test at significance level p< 0.05. Results: The results of this this study revealed no statistically significant difference between the Periotest readings for the implants in each category placed in either the OD or the regular osteotomies. However, it has been found that the implants placed in regular drilling ostoetomies had a significantly better primary stability than the implants placed in OD osteotomies. Conclusions: It was concluded that OD is not necessary in situations where there is bone of good quality and quantity.


Author(s):  
Yaniv Mayer ◽  
Ofir Ginesin ◽  
Hadar Zigdon-Giladi

Implant primary stability, which depends mainly on the amount and quality of bone, is important for implant survival. Socket preservation aims to reduce bone volumetric changes following tooth extraction. This animal study aims to examine whether preserving a ridge by using xenograft impairs the primary stability of the implant. Eighteen artificial bone defects were prepared in four sheep (5mmØ and 8mm length).  Defects were randomly grafted with xenografts: Bio-Oss (BO), Bioactive Bone (BB), or left for natural healing (control). After 8 weeks, bone biopsy was harvested and dental implants installed. During installation, peak insertion torque (IT) was measured by hand ratchet, and primary stability by the Osstell method. Histomorphometric analysis showed a higher percentage of new bone formation in the naturally healed defects compared to sites with xenograft (control 68.66 ± 4.5%, BB 48.75 ± 4.34%, BO 50.33 ± 4.0%). Connective tissue portion was higher in the BO and BB groups compared to control (44.25 ± 2.98%, 41 ± 6%, and 31.33 ± 4.5, p&lt;0.05, respectively). Residual grafting material was similar in BO and BB (7 ± 2.44%, 8.66 ± 2.1 %, respectively). Mean IT and ISQ values were not statistically different among the groups. A positive correlation was found between IT and ISQ (r=0.65, p=0.00). In conclusion, previously grafted defects with xenograft did not influence primary stability and implant insertion torque in delayed implant placement. These results may be attributed to a relatively high bone fill of the defect (~50%) two months after grafting.


2020 ◽  
Vol 46 (3) ◽  
pp. 182-189 ◽  
Author(s):  
Davide Farronato ◽  
Mattia Manfredini ◽  
Michele Stocchero ◽  
Mattia Caccia ◽  
Lorenzo Azzi ◽  
...  

The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks. The independent variables were: bone quality, drilling protocol, implant diameter, and implant length. Group A implants were inserted with a conventional drilling protocol, whereas Group B implants were inserted with an undersized drilling protocol. Values of IT and RFA were measured at implant installation. IT and RFA values were significantly correlated (Pearson correlation coefficient: 0.54). A multivariable analysis showed a strong model. Higher IT values were associated with drilling protocol B vs A (mean difference: 71.7 Ncm), implant length (3.6 Ncm increase per mm in length), and substrate density (0.199 Ncm increase per mg/cm3 in density). Higher RFA values were associated with drilling protocol B vs A (mean difference: 3.9), implant length (1.0 increase per mm in length), and substrate density (0.032 increase per mg/cm3 in density). Implant diameter was not associated with RFA or IT. Within the limitations of an in vitro study, the results of this study suggest that the studied implant can achieve good level of primary stability in terms of IT and RFA. A strong correlation was found between values of IT and RFA. Both parameters are influenced by the drilling protocol, implant length, and substrate density. Further studies are required to investigate the clinical response in primary stability and marginal bone response.


2021 ◽  
Vol 104 (1) ◽  
pp. 003685042098705
Author(s):  
Xinran Wang ◽  
Yangli Zhu ◽  
Wen Li ◽  
Dongxu Hu ◽  
Xuehui Zhang ◽  
...  

This paper focuses on the effects of the off-design operation of CAES on the dynamic characteristics of the triple-gear-rotor system. A finite element model of the system is set up with unbalanced excitations, torque load excitations, and backlash which lead to variations of tooth contact status. An experiment is carried out to verify the accuracy of the mathematical model. The results show that when the system is subjected to large-scale torque load lifting at a high rotating speed, it has two stages of relatively strong periodicity when the torque load is light, and of chaotic when the torque load is heavy, with the transition between the two states being relatively quick and violent. The analysis of the three-dimensional acceleration spectrum and the meshing force shows that the variation in the meshing state and the fluctuation of the meshing force is the basic reasons for the variation in the system response with the torque load. In addition, the three rotors in the triple-gear-rotor system studied show a strong similarity in the meshing states and meshing force fluctuations, which result in the similarity in the dynamic responses of the three rotors.


2021 ◽  
Vol 11 (12) ◽  
pp. 5612
Author(s):  
Stefano Fanali ◽  
Margherita Tumedei ◽  
Pamela Pignatelli ◽  
Alessandra Lucchese ◽  
Francesco Inchingolo ◽  
...  

Background: Implant primary stability can be affected by several factors related to implant macrogeometry, local anatomy, and surgical techniques. The aim of this research was to study primary stability on polyurethane foam sheets of wide-threaded implant design compared to narrow-threaded implants. Materials and methods: Two different implant designs were positioned on D3 density polyurethane blocks in a standardized environment: the wide-threaded implant and the narrow-threaded implant, for a total of 160 specimens. Moreover, for each group, two different sizes were considered: 3.8mm × 12mm and 4.8mm × 12 mm. The insertion torque (IT) values, the removal strength (RT), and the Periotest analyses were evaluated. Results: A significantly higher IT and RT was reported for wide-threaded implants and two-stage implants (p < 0.01), compared to the narrow-threaded implants. The diameters seemed to provide a significant effect on the primary stability for both implants’ geometry (p < 0.01). A higher mean of the one-stage implant was evident in the Periotest measurements (p < 0.01). Conclusions: Both of the implants showed sufficient stability in polyurethane artificial simulation, while the wide-threaded implant design showed a higher primary stability on alveolar cancellous synthetic bone in vitro. Additionally, the prosthetic joint connection seemed to have a determinant effect on Periotest analysis, and the one-stage implants seemed to provide a high stability of the fixture when positioned in the osteotomy, which could be important for the immediate loading protocol.


Sign in / Sign up

Export Citation Format

Share Document