The effect of cortical bone thickness on the primary stability of miniscrews, using CBCT (Cross-sectional clinical trial)

2018 ◽  
Vol 64 (2) ◽  
pp. 847-853
Author(s):  
Aly Osman ◽  
Ahmed Abdel Moneim ◽  
Nadia El Harouni ◽  
Mohamed Shokry
2019 ◽  
Vol 235 (5) ◽  
pp. 883-891 ◽  
Author(s):  
Sven A. Holcombe ◽  
Yun‐Seok Kang ◽  
Brian A. Derstine ◽  
Stewart C. Wang ◽  
Amanda M. Agnew

Materials ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2605
Author(s):  
Masaaki Takechi ◽  
Yasuki Ishioka ◽  
Yoshiaki Ninomiya ◽  
Shigehiro Ono ◽  
Misato Tada ◽  
...  

Background: Primary stability is an important prognostic factor for dental implant therapy. In the present study, we evaluate the relationship between implant stability evaluation findings by the use of an implant stability quotient (ISQ), an index for primary stability, and a morphological evaluation of bone by preoperative computed tomography (CT). Subjects and methods: We analyzed 98 patients who underwent implant placement surgery in this retrospective study. For all 247 implants, the correlations of the ISQ value with cortical bone thickness, cortical bone CT value, cancellous bone CT value, insertion torque value, implant diameter, and implant length were examined. Results: 1. Factors affecting ISQ values in all cases: It was revealed that there were significant associations between the cortical bone thickness and cancellous bone CT values with ISQ by multiple regression analysis. 2. It was revealed that there was a significant correlation between cortical bone thickness and cancellous bone CT values with ISQ by multiple regression analysis in the upper jaw. 3. It was indicated that there was a significant association between cortical bone thickness and implant diameter with ISQ by multiple regression analysis in the lower jaw. Conclusion: We concluded that analysis of the correlation of the ISQ value with cortical bone thickness and values obtained in preoperative CT imaging were useful preoperative evaluations for obtaining implant stability.


2019 ◽  
Vol 14 (4) ◽  
pp. 383-388
Author(s):  
Chin-Yun Pan ◽  
Pao-Hsin Liu ◽  
Yu-Chuan Tseng ◽  
Szu-Ting Chou ◽  
Chao-Yi Wu ◽  
...  

2021 ◽  
Vol 11 (3) ◽  
pp. 1183
Author(s):  
Lejla Redžepagić-Vražalica ◽  
Elmedin Mešić ◽  
Nedim Pervan ◽  
Vahidin Hadžiabdić ◽  
Muamer Delić ◽  
...  

This study investigated the correlation between bone characteristics, the design of orthodontic mini-implants, the pull-out force, and primary stability. This experimental in vitro study has examined commercial orthodontic mini-implants of different sizes and designs, produced by two manufacturers: Tomas-pin SD (Dentaurum, Ispringen, Germany) and Perfect Anchor (Hubit, Seoul, Korea). The total number of 40 mini-implants were tested. There are two properties that are common to all tested implants—one is the material of which they are made (titanium alloy Ti-6Al-4V), and the other is the method of their insertion. The main difference between the mini-implants, which is why they have been selected as the subject of research in the first place, is reflected in their geometry or design. Regardless of the type of implant, the average pull-out forces were found to be higher for a cortical bone thickness (CBTC) of 0.62–0.67 mm on average, compared to the CBTC < 0.62 mm, where the measured force averages were found to be lower. The analysis of variance tested the impact of the mini-implant geometry on the pull-out force and proved that there is a statistically significant impact (p < 0.015) of all three analyzed geometric factors on the pull-out force of the implant. The design of the mini-implant affects its primary stability. The design of the mini-implant affects the pulling force. The bone quality at the implant insertion point is important for primary stability; thus, the increase in the cortical bone thickness increases the value of the pulling force significantly.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 825.2-826
Author(s):  
M. Jansen ◽  
A. Ooms ◽  
T. D. Turmezei ◽  
J. W. Mackay ◽  
S. Mastbergen ◽  
...  

Background:In addition to cartilage degeneration, knee osteoarthritis (OA) causes bone changes, including cortical bone thickening, subchondral bone density decrease, and bone shape changes as a result of widening and flattening condyles and osteophyte formation. Knee joint distraction (KJD) is a joint-preserving treatment for younger (<65 years) knee OA patients that has been shown to reverse OA cartilage degradation. On radiographs, KJD showed a decrease in subchondral bone density and an increase in osteophyte formation. However, these bone changes have never been evaluated with a 3D imaging technique.Objectives:To evaluate cortical bone thickness, subchondral trabecular bone density, and bone shape on CT scans before and one year after KJD treatment.Methods:19 KJD patients were included in an extended imaging protocol, undergoing a CT scan before and one year after treatment. Stradview v6.0 was used for semi-automatic tibia and femur segmentation from axial thin-slice (0.45mm) CT scans. Cortical bone thickness (mm) and trabecular bone density (Hounsfield units, HU) were measured with an automated algorithm. Osteophytes were excluded. Afterwards, wxRegSurf v18 was used for surface registration. Registration data was used for bone shape measurements. MATLAB R2020a and the SurfStat MATLAB package were used for data analysis and visualization. Two-tailed F-tests were used to calculate changes over time. Two separate linear regression models were used to show the influence of baseline Kellgren-Lawrence grade and sex on the changes over time. Statistical significance was calculated with statistical parametric mapping; a p-value <0.05 was considered statistically significant. Bone shape changes were explored visually using vertex by vertex displacements between baseline and follow-up. Patients were separated into two groups based on whether their most affected compartment (MAC) was medial or lateral. Only patients with axial CT scans at both time points available for analysis were included for evaluation.Results:3 Patients did not have complete CTs and in 1 patient the imaged femur was too short, leaving 16 patients for tibial analyses and 15 patients for femoral analyses. The MAC was predominantly the medial side (medial MAC n=14; lateral n=2). Before treatment, the MAC cortical bone was compared to the rest of the joint (Figure 1). One year after treatment, MAC cortical thickness decreased, although this decrease of up to approximately 0.25 mm was not statistically significant. The trabecular bone density was also higher before treatment in the MAC, and a decrease was seen throughout the entire joint, although statistically significant only for small areas on mostly the MAC where this decrease was up to approximately 80 HU (Figure 1). Female patients and patients with a higher Kellgren-Lawrence grade showed a somewhat larger decrease in cortical bone thickness. Trabecular density decreased less for patients with a higher Kellgren-Lawrence grade, and female patients showed a higher density decrease interiorly while male patients showed a higher decrease exteriorly. None of this was statistically significant. The central areas of both compartments showed an outward shape change, while the outer ring showed inward changes.Conclusion:MAC cortical bone thickness shows a partial decrease after KJD. Trabecular bone density decreased on both sides of the joint, likely as a direct result of the bicompartmental unloading. For both subchondral bone parameters, MAC values became more similar to the LAC, indicating (partial) subchondral bone normalization in the most affected parts of the joint. The bone shape changes may indicate a reversal of typical OA changes, although the inward difference that was seen on the outer edges may be a result of osteophyte-related changes that might have affected the bone segmentation. In conclusion, KJD treatment shows subchondral bone normalization in the first year after treatment, and longer follow-up might show whether these changes are a temporary result of joint unloading or indicate more prolonged bone changes.Disclosure of Interests:None declared.


2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Sadaf Adibi ◽  
Alireza Shakibafard ◽  
Zohreh Karimi Sarvestani ◽  
Najmeh Saadat ◽  
Leila Khojastepour

Background. Usefulness of ultrasound (US) in detection of intrabony lesions has been showed. A cortical bone perforation or a very thin and intact cortical bone is prerequisite for this purpose.Objective. The current in vitro study was aimed at measuring the cut-off thickness of the overlying cortical bone which allows ultrasonic assessment of bony defects.Materials and Methods. 20 bovine scapula blocks were obtained. Samples were numbered from 1 to 20. In each sample, 5 artificial lesions were made. The lesions were made in order to increase the overlying bone thickness, from 0.1 mm in the first sample to 2 mm in the last one (with 0.1 mm interval). After that, the samples underwent ultrasound examinations by two practicing radiologists.Results. All five lesions in samples numbered 1 to 11 were detected as hypoechoic area. Cortical bone thickness more than 1.1 mm resulted in a failure in the detection of central lesions.Conclusion. We can conclude that neither bony perforation nor very thin cortical bones are needed to consider US to be an effective imaging technique in the evaluation of bony lesion.


Sign in / Sign up

Export Citation Format

Share Document