Sensitive paper-based analytical device for fast colorimetric detection of nitrite with smartphone

2018 ◽  
Vol 410 (11) ◽  
pp. 2665-2669 ◽  
Author(s):  
Xiu-Xiu Zhang ◽  
Yi-Zhen Song ◽  
Fang Fang ◽  
Zhi-Yong Wu
2021 ◽  
Author(s):  
Deepshikha Shahdeo ◽  
Azmat Ali Khan ◽  
Amer M Alanazi ◽  
Yun Suk Huh ◽  
Shruti Shukla ◽  
...  

Abstract Ochratoxin A (OTA) is one of the predominant mycotoxins that contaminate a wide range of food commodities. In the present study, a 36-mer aptamer was used as a molecular recognition element coupled with gold nanoparticles (AuNPs) for colorimetric detection of OTA in a microfluidic paper-based analytical device (µPADs). The µPADs consisted of three zones: control, detection, and sample, interconnected by channels. The biophysical characterizations of aptamer conjugated AuNPs were done by UV-vis spectroscopy (UV-vis), dynamic Light Scattering (DLS), and transmission electron microscopy (TEM). The developed colorimetric assay for OTA showed a limit of detection of 242, 545, and 95.69 ng/mL in water, corn, and groundnut, respectively. The HPLC detection method achieved acceptable coefficient in standard curves (r2 = 0.9995), better detection range, and recovery rates in spiked corn and groundnut samples as 43.61 ± 2.18% to 87.10 ± 1.82% and 42.01 ± 1.31% to 86.03 ± 2.64% after multiple sample extractions and cleanup steps. However, the developed µPADs analytical device had the potent ability to rapidly detect OTA without any extraction pre-requirement, derivatization, and cleanup steps, thus illustrating its feasibility in the animal health sector, agricultural, and food industries.


Sensors ◽  
2020 ◽  
Vol 20 (15) ◽  
pp. 4107 ◽  
Author(s):  
Sumate Pengpumkiat ◽  
Jintana Nammoonnoy ◽  
Watcharaporn Wongsakoonkan ◽  
Pajaree Konthonbut ◽  
Pornpimol Kongtip

A detection method for type-II pyrethroids in an environmental water sample using a microfluidic paper-based analytical device (µPAD) is reported here. The detection approach is based on the formation of cyanide from the hydrolysis of type-II pyrethroids and the colorimetric detection of cyanide on a layer-based µPAD. Parafilm and inexpensive laminating pouches were used to create a hydrophobic barrier for the assay on the µPAD. This detection approach was selective to type-II pyrethroids in water for which an environmental water sample was tested. The calibration curves for cypermethrin, deltamethrin, cyhalothrin, and fenvalerate ranged from 2 to 40 µg/mL without sample preconcentration. The lower concentrations of type-II pyrethroids can be assessed by including a preconcentration step prior to the detection on a µPAD. This detection system provides an alternative platform for fast, semiquantitative testing for pesticide contamination in environmental surface water by allowing for portability, low reagent/sample consumption, and low-cost testing.


2018 ◽  
Vol 1036 ◽  
pp. 80-88 ◽  
Author(s):  
Luhong Sun ◽  
Yujun Jiang ◽  
Ruili Pan ◽  
Mingyu Li ◽  
Rui Wang ◽  
...  

2016 ◽  
Vol 8 (38) ◽  
pp. 6965-6973 ◽  
Author(s):  
Sanjay Kumar ◽  
Pulak Bhushan ◽  
Shantanu Bhattacharya

A novel paper-based device for colorimetric detection of uric acid was developed based on the peroxidase-like activity of gold nanoparticles–graphene conjugates (AuNPs–GO).


2020 ◽  
Vol 159 ◽  
pp. 105463
Author(s):  
Gabriel M. Fernandes ◽  
Júlia de Sousa ◽  
João Flávio da Silveira Petruci ◽  
Alex D. Batista

The Analyst ◽  
2021 ◽  
Author(s):  
Vakkas Doğan ◽  
Elif Yüzer ◽  
Volkan Kilic ◽  
Mustafa Şen

In the present study, iodide-mediated 3,3’,5,5’-tetramethylbenzidine (TMB)-H2O2 reaction system was applied to a microfluidic paper-based analytical device (μPAD) for non-enzymatic colorimetric determination of H2O2. The proposed system is portable and...


Talanta ◽  
2021 ◽  
pp. 122301
Author(s):  
Maria Célia Tavares ◽  
Karoliny Almeida Oliveira ◽  
Ângelo de Fátima ◽  
Wendell K.T. Coltro ◽  
Josué Carinhanha Caldas Santos

Sign in / Sign up

Export Citation Format

Share Document