scholarly journals Quantitative serosal and mucosal optical imaging perfusion assessment in gastric conduits for esophageal surgery: an experimental study in enhanced reality

Author(s):  
Manuel Barberio ◽  
Eric Felli ◽  
Margherita Pizzicannella ◽  
Vincent Agnus ◽  
Mahdi Al-Taher ◽  
...  

Abstract Introduction/objective Gastric conduit (GC) is used for reconstruction after esophagectomy. Anastomotic leakage (AL) incidence remains high, given the extensive disruption of the gastric circulation. Currently, there is no reliable method to intraoperatively quantify gastric perfusion. Hyperspectral imaging (HSI) has shown its potential to quantify serosal StO2. Confocal laser endomicroscopy (CLE) allows for automatic mucosal microcirculation quantification as functional capillary density area (FCD-A). The aim of this study was to quantify serosal and mucosal GC’s microperfusion using HSI and CLE. Local capillary lactate (LCL) served as biomarker. Methods GC was formed in 5 pigs and serosal StO2% was quantified at 3 regions of interest (ROI) using HSI: fundus (ROI-F), greater curvature (ROI-C), and pylorus (ROI-P). After intravenous injection of sodium-fluorescein (0.5 g), CLE-based mucosal microperfusion was assessed at the corresponding ROIs, and LCLs were quantified via a lactate analyzer. Results StO2 and FCD-A at ROI-F (41 ± 10.6%, 3.3 ± 3.8, respectively) were significantly lower than ROI-C (68.2 ± 6.7%, p value: 0.005; 18.4 ± 7, p value: 0.01, respectively) and ROI-P (72 ± 10.4%, p value: 0.005; 15.7 ± 3.2 p value: 0.001). LCL value at ROI-F (9.6 ± 4.7 mmol/L) was significantly higher than at ROI-C (2.6 ± 1.2 mmol/L, p value: 0.04) and ROI-P (2.6 ± 1.3 mmol/L, p value: 0.04). No statistically significant difference was found in all metrics between ROI-C and ROI-P. StO2 correlated with FCD-A (Pearson’s r = 0.67). The LCL correlated negatively with both FCD-A (Spearman’s r =  − 0.74) and StO2 (Spearman’s r =  −  0.54). Conclusions GC formation causes a drop in serosal and mucosal fundic perfusion. HSI and CLE correlate well and might become useful intraoperative tools.

Cancers ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 2977 ◽  
Author(s):  
Manuel Barberio ◽  
Eric Felli ◽  
Raoul Pop ◽  
Margherita Pizzicannella ◽  
Bernard Geny ◽  
...  

Esophagectomy often presents anastomotic leaks (AL), due to tenuous perfusion of gastric conduit fundus (GCF). Hybrid (endovascular/surgical) ischemic gastric preconditioning (IGP), might improve GCF perfusion. Sixteen pigs undergoing IGP were randomized: (1) Max-IGP (n = 6): embolization of left gastric artery (LGA), right gastric artery (RGA), left gastroepiploic artery (LGEA), and laparoscopic division (LapD) of short gastric arteries (SGA); (2) Min-IGP (n = 5): LGA-embolization, SGA-LapD; (3) Sham (n = 5): angiography, laparoscopy. At day 21 gastric tubulation occurred and GCF perfusion was assessed as: (A) Serosal-tissue-oxygenation (StO2) by hyperspectral-imaging; (B) Serosal time-to-peak (TTP) by fluorescence-imaging; (C) Mucosal functional-capillary-density-area (FCD-A) index by confocal-laser-endomicroscopy. Local capillary lactates (LCL) were sampled. Neovascularization was assessed (histology/immunohistochemistry). Sham presented lower StO2 and FCD-A index (41 ± 10.6%; 0.03 ± 0.03 respectively) than min-IGP (66.2 ± 10.2%, p-value = 0.004; 0.22 ± 0.02, p-value < 0.0001 respectively) and max-IGP (63.8 ± 9.4%, p-value = 0.006; 0.2 ± 0.02, p-value < 0.0001 respectively). Sham had higher LCL (9.6 ± 4.8 mL/mol) than min-IGP (4 ± 3.1, p-value = 0.04) and max-IGP (3.4 ± 1.5, p-value = 0.02). For StO2, FCD-A, LCL, max- and min-IGP did not differ. Sham had higher TTP (24.4 ± 4.9 s) than max-IGP (10 ± 1.5 s, p-value = 0.0008) and min-IGP (14 ± 1.7 s, non-significant). Max- and min-IGP did not differ. Neovascularization was confirmed in both IGP groups. Hybrid IGP improves GCF perfusion, potentially reducing post-esophagectomy AL.


2021 ◽  
pp. 1-11
Author(s):  
Charlotte Daniere ◽  
Guillaume Louart ◽  
Benjamin Louart ◽  
Marylène Bacle ◽  
Florian Bazalgette ◽  
...  

<b><i>Background:</i></b> Microcirculatory alterations have been observed at the early phase of sepsis, although macrocirculation seems preserved. The aim of this study was to analyze the effect of crystalloid fluid therapy on mesenteric microcirculation, assessed by using the confocal laser endomicroscope Cellvizio®, in an endotoxic porcine model. <b><i>Methods:</i></b> It is a prospective endotoxic shock (lipopolysaccharide infusion) experimental trial. Piglets were divided into 3 groups: 6 in the sham group (no LPS injection, no fluid), 9 in the control group (LPS infusion, no fluid), and 6 in the crystalloids group (LPS infusion and fluid resuscitation with crystalloids). Fluid resuscitation consisted in a fluid bolus of 20 mL/kg 0.9% saline over 30 min followed by a 10 mL/kg/h fluid rate over 4 h. Mesenteric microcirculation was assessed using a confocal laser endomicroscope (Cellvizio®). Blood flow within capillaries was visually assessed according to the point of care microcirculation (POEM) score. <b><i>Results:</i></b> At baseline, the 3 groups were similar regarding hemodynamic, biological, and microcirculatory parameters. At T360, the POEM score significantly decreased in the control and crystalloids groups, whereas it remained unchanged in the sham group (respectively, 1.62 ± 1.06, 1.2 ± 0.45, and 5.0 ± 0, <i>p</i> = 0.011). There was no significant difference in cardiac output at T360 between the sham and crystalloids groups (3.1 ± 0.8 vs. 2.3 ± 0.6, <i>p</i> = 0.132) or between the control and crystalloids groups (2.0 ± 0.6 vs. 2.3 ± 0.6, <i>p</i> = 0.90). <b><i>Conclusion:</i></b> There was no significant improvement of microcirculatory alterations after crystalloids resuscitation despite improvement in macrocirculatory parameters in early experimental sepsis.


TAPPI Journal ◽  
2010 ◽  
Vol 9 (10) ◽  
pp. 7-15
Author(s):  
HANNA KOIVULA ◽  
DOUGLAS BOUSFIELD ◽  
MARTTI TOIVAKKA

In the offset printing process, ink film splitting has an important impact on formation of ink filaments. The filament size and its distribution influence the leveling of ink and hence affect ink setting and the print quality. However, ink filaments are difficult to image due to their short lifetime and fine length scale. Due to this difficulty, limited work has been reported on the parameters that influence filament size and methods to characterize it. We imaged ink filament remains and quantified some of their characteristics by changing printing speed, ink amount, and fountain solution type. Printed samples were prepared using a laboratory printability tester with varying ink levels and operating settings. Rhodamine B dye was incorporated into fountain solutions to aid in the detection of the filaments. The prints were then imaged with a confocal laser scanning microscope (CLSM) and images were further analyzed for their surface topography. Modeling of the pressure pulses in the printing nip was included to better understand the mechanism of filament formation and the origin of filament length scale. Printing speed and ink amount changed the size distribution of the observed filament remains. There was no significant difference between fountain solutions with or without isopropyl alcohol on the observed patterns of the filament remains.