Effects of smoking on the bone alkaline phosphatase in peri-implant crevicular fluid and implant stability quotient around implants before loading

Odontology ◽  
2022 ◽  
Author(s):  
Gulay Tuter ◽  
Arzu Zeynep Yildirim ◽  
Ayse Nurcan Duman ◽  
Behruz Aliyev ◽  
Aysegul Atak-Yucel ◽  
...  
Author(s):  
VARSHA PALLED ◽  
DR. JITENDRA RAO ◽  
DR. RAGHUWAR DAYAL SINGH ◽  
DR. SHUCHI TRIPATHI ◽  
DR. KALPANA SINGH ◽  
...  

The purpose of this study was to evaluate whether Low-Level Laser Therapy (LLLT) improves the healing of the implant surgical site with clinical and biochemical parameters.Thirty patients with an edentulous space spanning a single tooth were selected. The patients were randomly allocated to two groups - the control group and the test group. The test group received laser energy at a power of 2J/cm 2 with a total of 4-6J energy over each implant. Clinical parameters (Implant Stability Quotient, probing index, modified sulcus bleeding index)and osteoprotegerin (OPG) were assessed at baseline and follow-up intervals (2 weeks, 6 weeks, and 3 months).The test group showed significantly higher implant stability quotient compared to thecontrol group at 2 weeks(57.93±3.95 and 35.67±3.08; p<0.01) and 3months(58.86±3.75 and 67.06±3.78; p<0.01). A significant rise in OPG levels of the test group(686.30±125.36pg/ml at baseline and 784.25±108.30pg/ml at 3months;p<0.01) was seen contrary to significant decline in the control group (839.50±249.08pg/ml at baseline,415.30±78.39pg/ml at 3months;p<0.01). Within the limitations of the study, the study suggests that the healing of peri-implant hard and soft tissues may be enhanced with the use of LLLT as an explicit modality during the post-operative period.


Author(s):  
G. Bellastella ◽  
L. Scappaticcio ◽  
M. Longo ◽  
R. Carotenuto ◽  
C. Carbone ◽  
...  

Abstract Purpose The diagnosis of vitamin D deficiency is based on the determination of total plasma 25-hydroxyvitamin D (25-OHD) concentrations, but the regulation of vitamin D 25-hydroxylation is not a major consideration and very little information is available on this activity. To check what factors could interfere with the activity of vitamin D-25-hydroxylase and thus alter the 25-OHD concentrations, we looked for potential correlations between 25-OHD and results of liver function tests in healthy adults. Methods This single-centre study was retrospective and consisted of evaluating the correlations between 25-OHD and the activities of aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyl transpeptidase (GGT), alkaline phosphatase (ALP), and bone alkaline phosphatase (BALP) in 349 healthy subjects aged from 18 to 65 years. In particular, in Group 1 (n = 119), we looked for correlations between 25OHD and all liver function tests and in Group 2 (n = 230) the correlation between 25OHD and BALP. Results In Group 1, we found no correlation between 25OHD and AST (r =  − 0.03; p = 0.8), ALT (r =  − 0.02; p = 0.91), GGT (r =  − 0.08; p = 0.68), direct bilirubin (r =  − 0.02; p = 0.89), indirect bilirubin (r =  − 0.24; p = 0.21), and total bilirubin (r =  − 0.24; p = 0.21) but one between 25OHD and ALP (r =  − 0.2; p = 0.007); in Group 2, we found a significant negative correlation between 25-OHD and BALP (r =  − 0.2; p = 0.0008). Conclusions The correlations that we found suggest that ALP and BALP might be involved in the regulation of vitamin D-25-hydroxylase activity, but further studies are mandatory to confirm our assumptions.


2019 ◽  
Vol 45 (4) ◽  
pp. 259-266
Author(s):  
Claudio Stacchi ◽  
Matteo De Biasi ◽  
Lucio Torelli ◽  
Massimo Robiony ◽  
Roberto Di Lenarda ◽  
...  

The primary objective of the present in vitro study was to evaluate the influence of implant site preparation technique (drills vs ultrasonic instrumentation) on the primary stability of short dental implants with two different designs inserted in simulated low-quality cancellous bone. Eighty implant sites were prepared in custom-made solid rigid polyurethane blocks with two different low cancellous bone densities (5 or 15 pounds per cubic foot [PCF]), equally distributed between piezoelectric (Surgysonic Moto, Esacrom, Italy) and conventional drilling techniques. Two short implant systems (Prama and Syra, Sweden & Martina) were tested by inserting 40 fixtures of each system (both 6.0 mm length and 5.0 mm diameter), divided in the four subgroups (drills/5 PCF density; drills/15 PCF density; piezo/5 PCF density; piezo/15 PCF density). Insertion torque (Ncm), implant stability quotient values, removal torque (Ncm), and surgical time were recorded. Data were analyzed by 3-way ANOVA and Scheffé's test (α = 0.05). With slight variations among the considered dependent variables, overall high primary implant stability was observed across all subgroups. Piezoelectric instrumentation allowed for comparable or slightly superior primary stability in comparison with the drilling procedures in both implant systems. The Prama implants group showed the highest mean reverse torque and Syra implants the highest implant stability quotient values. Piezoelectric implant site preparation took prolonged operative time compared to conventional preparation with drills; among the drilling procedures, Syra system required fewer surgical steps and shorter operative time.


Author(s):  
J D Johnston ◽  
S Koneru ◽  
T Kuwana ◽  
S B Rosalki

Serum levels of bone-origin alkaline phosphatase and of tartrate-resistant acid phosphatase were measured in Caucasian women aged 41–69 years who had volunteered for bone densitometry. Bone alkaline phosphatase and tartrate-resistant acid phosphatase were inversely correlated with vertebral bone density and with femoral neck bone density. Bone alkaline phosphatase and acid phosphatase were also significantly correlated, consistent with the concept of ‘coupling’ between osteoblast and osteoclast activity.


2006 ◽  
Vol 14 ◽  
pp. S73-S74
Author(s):  
T.N. Trumble ◽  
M.P. Brown ◽  
K.A. Merritt ◽  
R.C. Billinghurst

Sign in / Sign up

Export Citation Format

Share Document