Evidence for bark thickness as a fire-resistance trait from desert to savanna in fire-prone inland Australia

Plant Ecology ◽  
2016 ◽  
Vol 217 (6) ◽  
pp. 683-696 ◽  
Author(s):  
A. T. Schubert ◽  
C. E. M. Nano ◽  
P. J. Clarke ◽  
M. J. Lawes
2012 ◽  
Vol 628 ◽  
pp. 156-160
Author(s):  
In Kyu Kwon ◽  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
Bum Yean Cho ◽  
Kyung Suk Cho

Structural steel has been used since the early 1970’s in Korea as primary structural members such as columns, beams, and trusses. The materials have much higher strength such as fast construction, high load bearing capacity, high construction quality but those have a fatal weakness as well. Load-bearing capacity is going down when the structural members are contained in fire condition. Therefore, to protect the structural members made of steels from the heat energy the fire resistance performance required. Generally, the fire resistance performance have evaluated from the exact fire tests in fire furnaces. But the evaluation method takes much more time and higher expenses so, the engineering method requires. The engineering method not only adopts a science but also an engineering experience. In this paper, to make various data-bases for evaluation of structural members such as columns(H-section, RHS), beams, loaded fire tests were conducted and derived not only each limiting temperature but also fire resistance respectively.


2021 ◽  
Vol 30 (5) ◽  
pp. 58-65
Author(s):  
A. Yu. Shebeko ◽  
Yu. N. Shebeko ◽  
A. V. Zuban

Introduction. GOST R 12.3.047-2012 standard offers a methodology for determination of required fire resistance limits of engineering structures. This methodology is based on a comparison of values of the fire resistance limit and the equivalent fire duration. However, in practice incidents occur when, in absence of regulatory fire resistance requirements, a facility owner, who has relaxed the fire resistance requirements prescribed by GOST R 12.3.047–2012, is ready to accept its potential loss in fire for economic reasons. In this case, one can apply the probability of safe evacuation and rescue to compare distributions of fire resistance limits, on the one hand, and evacuation and rescue time, on the other hand.A methodology for the identification of required fire resistance limits. The probabilistic method for the identification of required fire resistance limits, published in work [1], was tested in this study. This method differs from the one specified in GOST R 12.3.047-2012. The method is based on a comparison of distributions of such random values, as the estimated time of evacuation or rescue in case of fire at a production facility and fire resistance limits for engineering structures.Calculations of required fire resistance limits. This article presents a case of application of the proposed method to the rescue of people using the results of full-scale experiments, involving a real pipe rack at a gas processing plant [2].Conclusions. The required fire resistance limits for pipe rack structures of a gas processing plant were identified. The calculations took account of the time needed to evacuate and rescue the personnel, as well as the pre-set reliability of structures, given that the personnel evacuation and rescue time in case of fire is identified in an experiment.


2013 ◽  
Vol 62 (1) ◽  
Author(s):  
Md Azree Othuman Mydin

Drywall is a widespread fire barrier used in house and general building construction. Drywall partitions and ceiling membranes are possibly the most common fire resistant construction approach employed in an extensive range of building types. The utilization of drywall board as prime fire protection of light-flame wood or steel construction is ubiquitous. Drywall board based systems are among those now broadly used, as walls or ceilings and it is principally employed as lining material in light-weight construction, which is a competent and cost effective technique of providing flexible partitioning assemblies in commercial and residential buildings. The thickness of the drywall board lining and the configuration of the framing can be flexibly changed to meet specified fire performance requirements. The use of such systems is increasing every day and there demands to be more research on their properties and behaviour. This paper will presents the properties of drywall board which will includes the assemblies and standard fire tests and the thermal properties of drywall in general and includes suggested properties of drywall by different researchers. Drywall boards shrink and crack at high temperatures, and this leads to collapse of parts of the drywall boards in fire. Fall-off of gypsum in fire affects the fire resistance of the assembly considerably, and cannot be overlooked when evaluating the fire resistance of drywall assemblies


Author(s):  
Paweł Roszkowski ◽  
Paweł Sulik

<p>Sandwich panel is the material that is easy and quickly to install. Basing on a great experience in the area of determination of the fire resistance class of construction building elements the authors describe the properties and behavior of building elements made of the sandwich panels exposed to fire. The article presents the results of fire resistance tests carried out in accordance with EN 1364-1 non-bearing walls made of sandwich panels with use of different cores.</p>The following parameters were analyzed: temperature rise on unexposed side (I – thermal insulation), integrity (E) depending on the orientations and on the width of the sandwich panels, deflection depending on the thickness of the boards. Conclusions were made on the base of the analysis from fire resistance tests.


2020 ◽  
Vol 8 (7) ◽  
pp. 520 ◽  
Author(s):  
Giada Kyaw Oo D’Amore ◽  
Alberto Marinò ◽  
Jan Kašpar

Finite element analysis (FEA) is employed to simulate the thermo-resistance of a marine fire-proof door in the fire-resistance test defined by the International Code for the Application of Fire Test Procedures (2010 FTP Code) and required by the International Maritime Organization (IMO) for marine applications. The appropriate type of simulation adopted (i.e., steady or unsteady) is discriminated on the basis of a comparison between the numerical results and the experimental data. This appropriate model is used to evaluate the critical parameters affecting fire-proof door performance. A remarkable role of the thermal bridge at the door edges in fire resistance is assessed, along with the parameters that allow its reduction. These findings provide insight into how to design a thinner and lighter fire door.


1999 ◽  
Vol 26 (2) ◽  
pp. 156-167 ◽  
Author(s):  
D I Nwosu ◽  
VKR Kodur

A state-of-the-art review of the behaviour of steel frame structures in fire is presented. Results from different studies indicate that the behaviour of a complete structure is different from that of a single structural member under fire conditions from the point of view of fire resistance. Earlier studies also show that analysis and design of steel structures against fire based on their overall behaviour could lead to a reduction or the elimination of applied fire protection to certain structural members. The effects of continuity, restraint conditions, and load ratio on the fire resistance of frame structures are discussed. The beneficial aspects derived from considering overall structural rather than single-member behaviour in fire are illustrated through the analysis on two one-bay, one-storey, unprotected steel portal frames, a column, and a beam. Also comparison is made between the performance of a beam with different end restraints in fire. Results from the analyses indicate that the fire resistance of a member is increased when it is considered as part of a structure compared with when it is considered as a single member.Key words: steel, frames, fire resistance, buckling, loads, overall structural behaviour.


2013 ◽  
Vol 351-352 ◽  
pp. 42-45
Author(s):  
Yao Yao

Up till now, the design code for the determination of fire resistance of reinforced concrete (RC) columns is essentially based on tabulated data. Clearly, a more scientific approach based on an understanding of the fundamental behavior of columns in fire is timely andwill be useful to structural engineers. This paper develops a straightforward and rational method to predict the fire resistance of RC columns,which is based on the traditional Rankine approach. The effect of shear bond, if included in the Rankine approach, will yield moreaccurate predictions. Material deterioration at elevated temperature with regard to the strength and stability of columns is also quantified.


Sign in / Sign up

Export Citation Format

Share Document