Ultimate Strength and Its Application to Post-Earthquake Fire Resistance of Steel Frames in Fire

Author(s):  
Hiroyuki Suzuki
1999 ◽  
Vol 26 (2) ◽  
pp. 156-167 ◽  
Author(s):  
D I Nwosu ◽  
VKR Kodur

A state-of-the-art review of the behaviour of steel frame structures in fire is presented. Results from different studies indicate that the behaviour of a complete structure is different from that of a single structural member under fire conditions from the point of view of fire resistance. Earlier studies also show that analysis and design of steel structures against fire based on their overall behaviour could lead to a reduction or the elimination of applied fire protection to certain structural members. The effects of continuity, restraint conditions, and load ratio on the fire resistance of frame structures are discussed. The beneficial aspects derived from considering overall structural rather than single-member behaviour in fire are illustrated through the analysis on two one-bay, one-storey, unprotected steel portal frames, a column, and a beam. Also comparison is made between the performance of a beam with different end restraints in fire. Results from the analyses indicate that the fire resistance of a member is increased when it is considered as part of a structure compared with when it is considered as a single member.Key words: steel, frames, fire resistance, buckling, loads, overall structural behaviour.


2012 ◽  
Vol 628 ◽  
pp. 156-160
Author(s):  
In Kyu Kwon ◽  
Hyung Jun Kim ◽  
Heung Youl Kim ◽  
Bum Yean Cho ◽  
Kyung Suk Cho

Structural steel has been used since the early 1970’s in Korea as primary structural members such as columns, beams, and trusses. The materials have much higher strength such as fast construction, high load bearing capacity, high construction quality but those have a fatal weakness as well. Load-bearing capacity is going down when the structural members are contained in fire condition. Therefore, to protect the structural members made of steels from the heat energy the fire resistance performance required. Generally, the fire resistance performance have evaluated from the exact fire tests in fire furnaces. But the evaluation method takes much more time and higher expenses so, the engineering method requires. The engineering method not only adopts a science but also an engineering experience. In this paper, to make various data-bases for evaluation of structural members such as columns(H-section, RHS), beams, loaded fire tests were conducted and derived not only each limiting temperature but also fire resistance respectively.


2021 ◽  
Vol 30 (5) ◽  
pp. 58-65
Author(s):  
A. Yu. Shebeko ◽  
Yu. N. Shebeko ◽  
A. V. Zuban

Introduction. GOST R 12.3.047-2012 standard offers a methodology for determination of required fire resistance limits of engineering structures. This methodology is based on a comparison of values of the fire resistance limit and the equivalent fire duration. However, in practice incidents occur when, in absence of regulatory fire resistance requirements, a facility owner, who has relaxed the fire resistance requirements prescribed by GOST R 12.3.047–2012, is ready to accept its potential loss in fire for economic reasons. In this case, one can apply the probability of safe evacuation and rescue to compare distributions of fire resistance limits, on the one hand, and evacuation and rescue time, on the other hand.A methodology for the identification of required fire resistance limits. The probabilistic method for the identification of required fire resistance limits, published in work [1], was tested in this study. This method differs from the one specified in GOST R 12.3.047-2012. The method is based on a comparison of distributions of such random values, as the estimated time of evacuation or rescue in case of fire at a production facility and fire resistance limits for engineering structures.Calculations of required fire resistance limits. This article presents a case of application of the proposed method to the rescue of people using the results of full-scale experiments, involving a real pipe rack at a gas processing plant [2].Conclusions. The required fire resistance limits for pipe rack structures of a gas processing plant were identified. The calculations took account of the time needed to evacuate and rescue the personnel, as well as the pre-set reliability of structures, given that the personnel evacuation and rescue time in case of fire is identified in an experiment.


2013 ◽  
Vol 62 (1) ◽  
Author(s):  
Md Azree Othuman Mydin

Drywall is a widespread fire barrier used in house and general building construction. Drywall partitions and ceiling membranes are possibly the most common fire resistant construction approach employed in an extensive range of building types. The utilization of drywall board as prime fire protection of light-flame wood or steel construction is ubiquitous. Drywall board based systems are among those now broadly used, as walls or ceilings and it is principally employed as lining material in light-weight construction, which is a competent and cost effective technique of providing flexible partitioning assemblies in commercial and residential buildings. The thickness of the drywall board lining and the configuration of the framing can be flexibly changed to meet specified fire performance requirements. The use of such systems is increasing every day and there demands to be more research on their properties and behaviour. This paper will presents the properties of drywall board which will includes the assemblies and standard fire tests and the thermal properties of drywall in general and includes suggested properties of drywall by different researchers. Drywall boards shrink and crack at high temperatures, and this leads to collapse of parts of the drywall boards in fire. Fall-off of gypsum in fire affects the fire resistance of the assembly considerably, and cannot be overlooked when evaluating the fire resistance of drywall assemblies


Author(s):  
Paweł Roszkowski ◽  
Paweł Sulik

<p>Sandwich panel is the material that is easy and quickly to install. Basing on a great experience in the area of determination of the fire resistance class of construction building elements the authors describe the properties and behavior of building elements made of the sandwich panels exposed to fire. The article presents the results of fire resistance tests carried out in accordance with EN 1364-1 non-bearing walls made of sandwich panels with use of different cores.</p>The following parameters were analyzed: temperature rise on unexposed side (I – thermal insulation), integrity (E) depending on the orientations and on the width of the sandwich panels, deflection depending on the thickness of the boards. Conclusions were made on the base of the analysis from fire resistance tests.


Author(s):  
Carlos Couto ◽  
Thiago Silva ◽  
Martina Carić ◽  
Paulo Vila Real ◽  
Davor Skejić

<p>According to the Eurocode 3 Part 1-2 (EN1993-1-2) (CEN 2005b), it is possible for structural engineers to consider physical based thermal actions and to do performance based design instead of using prescriptive rules based on nominal fire curves. However, some uncertainties remain in the use of such approaches. This study focus on the clarification of the use of the simplified design methods to assess the fire resistance of unbraced steel frames exposed to fire. On the other hand, a recent study (Couto et al. 2013) suggests the use of a buckling coefficient of 1.0 for all the columns except those belonging to the first storey of a pinned framed where 2.0 should be taken instead and it is unclear if the consideration of such values for the buckling lengths is adequate when using performance based designs.</p>In this study, a comparison is made between simple and advanced calculation models and it is demonstrated that the simple design methods, using the suggested buckling coefficients to calculate the fire resistance of the frames are safe sided when compared to the use of advanced calculations using the finite element method (FEM).


2020 ◽  
Vol 164 ◽  
pp. 105754 ◽  
Author(s):  
Mian Zhou ◽  
Liming Jiang ◽  
Suwen Chen ◽  
Rui P.R. Cardoso ◽  
Asif Usmani

2012 ◽  
Vol 446-449 ◽  
pp. 793-796
Author(s):  
Hui Zhu ◽  
Yu Ching Wu

In this paper, co-rotational total Lagrangian finite element formulation is derived, and the corresponding numerical model is developed to study creeping behavior of plane steel frames in fire. Geometrical nonlinearity, material nonlinearity, high temperature creeping, and temperature rising rate are taken into account. To verify accuracy and efficiency of the numerical model, four prototypical numerical examples are analyzed using this model. Results are in a great agreement with solutions in literatures. Then the numerical model is used to analyze creeping behavior of the plane steel frames when temperature is lowering. The numerical results have significant contribution to resistance and protection for steel structures against disastrous fires.


Sign in / Sign up

Export Citation Format