Porosity effects on the peristaltic flow of biological fluid in a complex wavy channel

Pramana ◽  
2021 ◽  
Vol 96 (1) ◽  
Author(s):  
Khurram Javid ◽  
Zeeshan Asghar ◽  
Umer Saeed ◽  
Muhammad Waqas
2015 ◽  
Vol 46 (7) ◽  
pp. 643-656 ◽  
Author(s):  
Obaid Ullah Mehmood ◽  
Norzieha Mustapha ◽  
Sharidan Shafie ◽  
Muhammad Qasim

2008 ◽  
Vol 11 (1) ◽  
pp. 51-71 ◽  
Author(s):  
Manoranjan Mishra ◽  
A. Ramachandra Rao

Author(s):  
G. Manjunatha ◽  
C. Rajashekhar ◽  
K. V. Prasad ◽  
Hanumesh Vaidya ◽  
Saraswati

The present article addresses the peristaltic flow of a Jeffery fluid over an inclined axisymmetric porous tube with varying viscosity and thermal conductivity. Velocity slip and convective boundary conditions are considered. Resulting governing equations are solved using long wavelength and small Reynolds number approximations. The closed-form solutions are obtained for velocity, streamline, pressure gradient, temperature, pressure rise, and frictional force. The MATLAB numerical simulations are utilized to compute pressure rise and frictional force. The impacts of various physical parameters in the interims for time-averaged flow rate with pressure rise and is examined. The consequences of sinusoidal, multi-sinusoidal, triangular, trapezoidal, and square waveforms on physiological parameters are analyzed and discussed through graphs. The analysis reveals that the presence of variable viscosity helps in controlling the pumping performance of the fluid.


2014 ◽  
Vol 10 (5) ◽  
pp. 709-721 ◽  
Author(s):  
S. Nadeem ◽  
Hina Sadaf ◽  
M. Sadiq
Keyword(s):  

1983 ◽  
Vol 48 (10) ◽  
pp. 2903-2908 ◽  
Author(s):  
Viktor Vrabec ◽  
Oldřich Vrána ◽  
Vladimír Kleinwächter

A method is described for determining total platinum content in urine, blood plasma and tissues of patients or experimental animals receiving cis-dichlorodiamineplatinum(II). The method is based on drying and combustion of the biological material in a muffle furnace. The product of the combustion is dissolved successively in aqua regia, hydrochloric acid and ethylenediamine. The resulting platinum-ethylenediamine complex yields a catalytic current at a dropping mercury electrode allowing to determine platinum by differential pulse polarography. Platinum levels of c. 50-1 000 ng per ml of the biological fluid or per 0.5 g of a tissue can readily be analyzed with a linear calibration.


Heat Transfer ◽  
2021 ◽  
Author(s):  
C. Rajashekhar ◽  
F. Mebarek‐Oudina ◽  
H. Vaidya ◽  
K. V. Prasad ◽  
G. Manjunatha ◽  
...  

1998 ◽  
Vol 41 (2) ◽  
pp. 447-453 ◽  
Author(s):  
Takashi OHTA ◽  
Yutaka MIYAKE ◽  
Takeo KAJISHIMA

Sign in / Sign up

Export Citation Format

Share Document