In Vitro Mechanical Property Evaluation of Chitosan-Based Hydrogels Intended for Vascular Graft Development

2017 ◽  
Vol 10 (5-6) ◽  
pp. 480-488 ◽  
Author(s):  
Audrey Aussel ◽  
Alexandra Montembault ◽  
Sébastien Malaise ◽  
Marie Pierre Foulc ◽  
William Faure ◽  
...  
1985 ◽  
Vol 54 (04) ◽  
pp. 842-848 ◽  
Author(s):  
Kandice Kottke-Marchant ◽  
James M Anderson ◽  
Albert Rabinovitch ◽  
Richard A Huskey ◽  
Roger Herzig

SummaryHeparin is known to affect platelet function in vitro, but little is known about the effect of heparin on the interaction of platelets with polymer surfaces in general, and vascular graft materials in particular. For this reason, the effect of heparin vs. citrate anticoagulation on the interaction of platelets with the vascular graft materials expanded polytetrafluoroethylene (ePTFE), Dacron Bionit (DB) and preclotted Dacron Bionit (DB/PC) was studied in a recirculating, in vitro perfusion system. Platelet activation, as shown by a decrease in platelet count, an increase in platelet release and a decrease in platelet aggregation, was observed for all vascular graft materials tested using heparin and was greater for Dacron and preclotted Dacron than for ePTFE. Significant differences between heparin and citrate anticoagulation were seen for platelet release, platelet aggregation and the relative ranking of material platelet-reactivity. However, the trends and time course of platelet activation were similar with both heparin and citrate for the materials tested.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
Edward X. Han ◽  
Hong Qian ◽  
Bo Jiang ◽  
Maria Figetakis ◽  
Natalia Kosyakova ◽  
...  

AbstractA significant barrier to implementation of cell-based therapies is providing adequate vascularization to provide oxygen and nutrients. Here we describe an approach for cell transplantation termed the Therapeutic Vascular Conduit (TVC), which uses an acellular vessel as a scaffold for a hydrogel sheath containing cells designed to secrete a therapeutic protein. The TVC can be directly anastomosed as a vascular graft. Modeling supports the concept that the TVC allows oxygenated blood to flow in close proximity to the transplanted cells to prevent hypoxia. As a proof-of-principle study, we used erythropoietin (EPO) as a model therapeutic protein. If implanted as an arteriovenous vascular graft, such a construct could serve a dual role as an EPO delivery platform and hemodialysis access for patients with end-stage renal disease. When implanted into nude rats, TVCs containing EPO-secreting fibroblasts were able to increase serum EPO and hemoglobin levels for up to 4 weeks. However, constitutive EPO expression resulted in macrophage infiltration and luminal obstruction of the TVC, thus limiting longer-term efficacy. Follow-up in vitro studies support the hypothesis that EPO also functions to recruit macrophages. The TVC is a promising approach to cell-based therapeutic delivery that has the potential to overcome the oxygenation barrier to large-scale cellular implantation and could thus be used for a myriad of clinical disorders. However, a complete understanding of the biological effects of the selected therapeutic is absolutely essential.


2021 ◽  
Vol 12 ◽  
pp. 204173142110277
Author(s):  
Edward X Han ◽  
Juan Wang ◽  
Mehmet Kural ◽  
Bo Jiang ◽  
Katherine L Leiby ◽  
...  

Transplantation of pancreatic islets has been shown to be effective, in some patients, for the long-term treatment of type 1 diabetes. However, transplantation of islets into either the portal vein or the subcutaneous space can be limited by insufficient oxygen transfer, leading to islet loss. Furthermore, oxygen diffusion limitations can be magnified when islet numbers are increased dramatically, as in translating from rodent studies to human-scale treatments. To address these limitations, an islet transplantation approach using an acellular vascular graft as a vascular scaffold has been developed, termed the BioVascular Pancreas (BVP). To create the BVP, islets are seeded as an outer coating on the surface of an acellular vascular graft, using fibrin as a hydrogel carrier. The BVP can then be anastomosed as an arterial (or arteriovenous) graft, which allows fully oxygenated arterial blood with a pO2 of roughly 100 mmHg to flow through the graft lumen and thereby supply oxygen to the islets. In silico simulations and in vitro bioreactor experiments show that the BVP design provides adequate survivability for islets and helps avoid islet hypoxia. When implanted as end-to-end abdominal aorta grafts in nude rats, BVPs were able to restore near-normoglycemia durably for 90 days and developed robust microvascular infiltration from the host. Furthermore, pilot implantations in pigs were performed, which demonstrated the scalability of the technology. Given the potential benefits provided by the BVP, this tissue design may eventually serve as a solution for transplantation of pancreatic islets to treat or cure type 1 diabetes.


ASAIO Journal ◽  
1993 ◽  
Vol 39 (3) ◽  
pp. M501-M505 ◽  
Author(s):  
HlROMICHI MlWA ◽  
TAKEHISA MATSUDA ◽  
NOBUTAKA TANI ◽  
KENSUKE KONDO ◽  
FUTOSHI llDA
Keyword(s):  

2006 ◽  
Vol 309-311 ◽  
pp. 801-804 ◽  
Author(s):  
S.B. Cho ◽  
Akari Takeuchi ◽  
Ill Yong Kim ◽  
Sang Bae Kim ◽  
Chikara Ohtsuki ◽  
...  

In order to overcome the disadvantage of commercialized PMMA bone cement, we have developed novel PMMA-based bone cement(7P3S) reinforced by 30 wt.% of bioactive CaO-SiO2 gel powders to induce the bioactivity as well as to increase mechanical property for the PMMA bone cement. The novel 7P3S bone cement hardened after mixing for about 7 minutes. For in vitro evaluation, apatite forming ability of it was investigated using SBF. When the novel 7P3S bone cement was soaked into SBF, it formed apatite on its surfaces within 1 week Furthermore; there is no decrease in its compressive strength within 9 weeks soaking in SBF. It is though that hardly decrease in compressive strength of 7P3S bone cement in SBF is due to the relative small amount of gel powder or its spherical shape and monosize. In vivo evaluation of the novel 7P3S bone cement was carried out using rabbit. After implantion into rabbit tibia for several periods, the interface between novel bone cement and natural bone was evaluated by CT images. According to the results, the novel bone cement directly contact to the natural bone without fibrous tissue after implantation for 4 weeks. This results indicates that the newly developed 7P3S bone cement can bond to the living bone and also be effectively used as bioactive bone cement without decrease in mechanical property.


2009 ◽  
Vol 25 (04) ◽  
pp. 198-205
Author(s):  
George W. Ritter ◽  
David R. Speth ◽  
Yu Ping Yang

This paper describes a straightforward method for the design and certification of adhesively bonded composite to steel joints for the marine industry. Normally, certification is based on documented service at sea. Since these joints have not been previously deployed at sea, no data on their performance exist. Using an integrated combination of mechanical property evaluation and finite element modeling, the load- bearing capacity of a joint can be compared with the anticipated seaway loads. Calculated factors of safety for the sandwich design used here show that the joint has adequate strength to maintain structural integrity even after severe environmental exposure.


2018 ◽  
Vol 33 (5) ◽  
pp. 543-557 ◽  
Author(s):  
Jianfei Cao ◽  
Yue Lu ◽  
Hechun Chen ◽  
Lifang Zhang ◽  
Chengdong Xiong

Poly(etheretherketone) exhibits good biocompatibility, excellent mechanical properties, and bone-like stiffness. However, the natural bio-inertness of pure poly(etheretherketone) hinders its applications in biomedical field, especially when direct bone-implant osteo-integration is desired. For developing an alternative biomaterial for load-bearing orthopedic application, combination of bioactive fillers with poly(etheretherketone) matrix is a feasible approach. In this study, a bioactive multi-walled carbon nanotubes/calcium polyphosphate/poly(etheretherketone) composite was prepared through a compounding and injection-molding process for the first time. Bioactive calcium polyphosphate was added to polymer matrix to enhance the bioactivity of the composite, and incorporation of multi-walled carbon nanotubes to composite was aimed to improve both the mechanical property and biocompatibility. Furthermore, the microstructures, surface hydrophilicity, and mechanical property of multi-walled carbon nanotubes/calcium polyphosphate/poly(etheretherketone) composite, as well as the cellular responses of MC3T3-E1 osteoblast cells to this material were investigated. The mechanical testing revealed that mechanical performance of the resulting ternary composite was significantly enhanced by adding the multi-walled carbon nanotubes and the mechanical values obtained were close to or higher than those of human cortical bone. More importantly, cell culture tests showed that initial cell adhesion, cell viability, and osteogenic differentiation of MC3T3-E1 cells were significantly promoted on the multi-walled carbon nanotubes/calcium polyphosphate/poly(etheretherketone) composite. Accordingly, the multi-walled carbon nanotubes/calcium polyphosphate/poly(etheretherketone) composite may be used as a promising bone repair material in dental and orthopedic applications.


Author(s):  
Deepak C Patil ◽  
K Venkateswarlu ◽  
S A Kori ◽  
Goutam Das ◽  
Mousumi Das ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document