scholarly journals Fragility Analysis of Atmospheric Storage Tanks by Observational and Analytical Data

Author(s):  
Fırat Bezir ◽  
Sezer Öztürk ◽  
Ali Sarı ◽  
Kayahan Akgül
2019 ◽  
Vol 2019 ◽  
pp. 1-15
Author(s):  
Sangmok Lee ◽  
Byungmin Kim ◽  
Young-Joo Lee

Liquid-containing storage tanks are important structures in industrial complexes. Because earthquake damages to liquid storage tanks can cause structural collapse, fires, and hazardous material leaks, there have been continuous efforts to mitigate earthquake damages using seismic fragility analysis. In this regard, this study focuses on the seismic responses and fragility of liquid storage tanks. First, the characteristics of earthquake ground motions are a critical factor influencing the seismic fragility of structures; thus, this study employs real earthquake records observed in the target area, southeastern Korea, with the earthquake characteristics estimated based on the ratio of peak ground acceleration to peak ground velocity. When a liquid storage tank oscillates during an earthquake, additional forces can impact the tank wall owing to hydrodynamic pressures. Therefore, this study presents a sophisticated finite element (FE) model that reflects the hydrodynamic effect of an oscillating liquid. Another advantage of such an FE model is that detailed structural responses of the entire wall shells can be estimated; this is not possible in simplified lumped mass or surrogate models. Lastly, probabilistic seismic demand models are derived for three critical limit states: elastic buckling, elephant’s foot buckling, and steel yielding. Using the real earthquake ground motion records, constructed FE model, and limit states, a seismic fragility analysis is performed for a typical anchored steel liquid storage tank in Korea. In addition, for comparison purposes, a ring-stiffened model is investigated to derive a seismic fragility curve. The results of the seismic fragility assessment show that elastic buckling is the most vulnerable damage state. In contrast, elephant’s foot buckling and steel yielding indicate relatively severe damage levels. Furthermore, it is observed that ring stiffeners decrease the elastic buckling damage, although there is no practical effect on elephant’s foot buckling and steel yielding in all ground motion intensities.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
Hoang Nam Phan ◽  
Fabrizio Paolacci ◽  
Silvia Alessandri

Catastrophic failure of the above ground steel storage tanks was observed during past earthquakes, which caused serious economic and environmental consequences. Many of the existing tanks were designed in the past with outdated analysis methods and with underestimated seismic loads. Therefore, the evaluation of the seismic vulnerability of these tanks, especially ones located in seismic prone areas, is extremely important. Seismic fragility functions are useful tools to quantify the seismic vulnerability of structures in the framework of probabilistic seismic risk assessment. These functions give the probability that a seismic demand on a given structural component meets or exceeds its capacity. The objective of this study is to examine the seismic vulnerability of an unanchored steel storage tank, considering the uncertainty of modeling parameters that are related to material and geometric properties of the tank. The significance of uncertain modeling parameters is first investigated with a screening study, which is based on nonlinear static pushover analyses of the tank using the abaqus software. In this respect, a fractional factorial design and an analysis of variance (ANOVA) have been adopted. The results indicate that the considered modeling parameters have significant effects on the uplift behavior of the tank. The fragility curves of two critical failure modes, i.e., the buckling of the shell plate and the plastic rotation of the shell-to-bottom plate joint, are then developed based on a simplified model of the tank, where the uplift behavior is correctly modeled from the static pushover analysis. The uncertainty associated with the significant parameters previously identified are considered in the fragility analysis using a sampling procedure to generate statistically significant samples of the model. The relative importance of different treatment levels of the uncertainty on the fragility curves of the tank is assessed and discussed in detail.


Author(s):  
Hoang Nam Phan ◽  
Fabrizio Paolacci ◽  
Silvia Alessandri ◽  
Phuong Hoa Hoang

Earthquake damage in recent decades has revealed that storage tanks are one of the most vulnerable components in petrochemical and oil processing plants. Damage to tanks commonly associated with losses of containment, and thus results in the overall damage to nearby areas. Many of existing steel storage tanks were designed with outdated analysis methods and with underestimated seismic loads; therefore, various types of failure may occur during a strong ground shaking. This paper aims to present an appropriate methodology for the component fragility evaluation of existing storage tanks in a process plant, which will support for the determination of the loss of containment in terms of the ground motion intensity measure and finally the quantitative risk analysis of the plant and its nearby areas. In this respect, an unanchored oil storage tank, which is ideally located in Sicily (Italy), is selected as a case study. The significance of modeling parameters of the tank is first investigated with a screening study, which is based on nonlinear static pushover analyses of the tank using the ABAQUS software. The study aims to enhance the understanding of which modeling parameters significantly affect the seismic response of the tank and to reduce the number of analyses in the fragility evaluation. The fragility curves are then developed based on a lumped-mass model that is calibrated from the static pushover analysis results. Sources of uncertainty, related to significant parameters previously identified, are considered in the fragility analysis using a sampling procedure to generate statistically significant samples of the model.


Author(s):  
W. Braue ◽  
R.W. Carpenter ◽  
D.J. Smith

Whisker and fiber reinforcement has been established as an effective toughening concept for monolithic structural ceramics to overcome limited fracture toughness and brittleness. SiC whiskers in particular combine both high strength and elastic moduli with good thermal stability and are compatible with most oxide and nonoxide matrices. As the major toughening mechanisms - crack branching, deflection and bridging - in SiC whiskenreinforced Al2O3 and Si3N41 are critically dependent on interface properties, a detailed TEM investigation was conducted on whisker/matrix interfaces in these all-ceramic- composites.In this study we present HREM images obtained at 400 kV from β-SiC/α-Al2O3 and β-SiC/β-Si3N4 interfaces, as well as preliminary analytical data. The Al2O3- base composite was hotpressed at 1830 °C/60 MPa in vacuum and the Si3N4-base material at 1725 °C/30 MPa in argon atmosphere, respectively, adding a total of 6 vt.% (Y2O3 + Al2O3) to the latter to promote densification.


2020 ◽  
Vol 99 (4) ◽  
pp. 344-350
Author(s):  
Evgeny V. Zibarev ◽  
A. S. Afanasev ◽  
O. V. Slusareva ◽  
T. I. Muragimov ◽  
V. A. Stepanets ◽  
...  

In recent years, in the Russian Federation there has been an increase in the levels of radiofrequency electromagnetic fields in residential areas, including due to an increase in the number of base stations (BS). The purpose of sanitary and epidemiological surveillance at the stages of placement and commissioning of base stations (BS) is to prevent their adverse effects on public health. The increase in the number of base stations, together with the advent of new electronic equipment and antennas, provide opportunities for improving the processes of their accounting at the stage of placement and monitoring of the levels of radiofrequency electromagnetic fields at the operation stage. This automation tool can be a geo-information portal for providing sanitary and epidemiological surveillance of cellular base stations. The prototype of the geo-information portal allows both calculating the size of sanitary protection zones (SPZ) and building restriction zones (RZ) from the BS in online mode, displaying the results of calculations in graphical form and issuing sanitary and epidemiological conclusions for the placement and operation of base stations. The geo-information portal has the ability to synchronize with the data of the radio frequency center. Federal Service for Surveillance on Consumer Rights Protection and Human Wellbeing will be able to receive up-to-date analytical data. There will be completely automated processes of collecting, processing and storing information on BS.


Sign in / Sign up

Export Citation Format

Share Document