The Effects of Splinting on the Initial Stability and Displacement Pattern of Periodontio-Integrated Dental Implants: A Finite Element Investigation

2020 ◽  
Vol 40 (5) ◽  
pp. 719-726
Author(s):  
Hossein Jokar ◽  
Gholamreza Rouhi ◽  
Nabiollah Abolfathi
Author(s):  
Ali Merdji ◽  
Belaid Taharou ◽  
Rajshree Hillstrom ◽  
Ali Benaissa ◽  
Sandipan Roy ◽  
...  

Author(s):  
Luiz Bassi Junior ◽  
Rafael Oliveira de Souza Silva ◽  
Victor Hugo Dias dos Santos ◽  
Abner da Rocha Lourenço ◽  
Paulo Vinicius Trevizoli ◽  
...  

Author(s):  
João PO Freitas ◽  
Bruno Agostinho Hernandez ◽  
Paulo J Paupitz Gonçalves ◽  
Edmea C Baptista ◽  
Edson A Capello Sousa

Dental implants are widely used as a long-term treatment solution for missing teeth. A titanium implant is inserted into the jawbone, acting as a replacement for the lost tooth root and can then support a denture, crown or bridge. This allows discreet and high-quality aesthetic and functional improvement, boosting patient confidence. The use of implants also restores normal functions such as speech and mastication. Once an implant is placed, the surrounding bone will fuse to the titanium in a process known as osseointegration. The success of osseointegration is dependent on stress distribution within the surrounding bone and thus implant geometry plays an important role in it. Optimisation analyses are used to identify the geometry which results in the most favourable stress distribution, but the traditional methodology is inefficient, requiring analysis of numerous models and parameter combinations to identify the optimal solution. A proposed improvement to the traditional methodology includes the use of Design of Experiments (DOE) together with Response Surface Methodology (RSM). This would allow for a well-reasoned combination of parameters to be proposed. This study aims to use DOE, RSM and finite element models to develop a simplified optimisation analysis method for dental implant design. Drawing on data and results from previous studies, two-dimensional finite element models of a single Branemark implant, a multi-unit abutment, two prosthetic screws, a prosthetic crown and a region of mandibular bone were built. A small number of combinations of implant diameter and length were set based on the DOE method to analyse the influence of geometry on stress distribution at the bone-implant interface. The results agreed with previous studies and indicated that implant length is the critical parameter in reducing stress on cortical bone. The proposed method represents a more efficient analysis of multiple geometrical combinations with reduced time and computational cost, using fewer than a third of the models required by the traditional methods. Further work should include the application of this methodology to optimisation analyses using three-dimensional finite element models.


1968 ◽  
Vol 72 (687) ◽  
pp. 245-246 ◽  
Author(s):  
P. C. Dunne

It is generally accepted that the displacement patterns chosen to represent the deformation of a finite element should be such that there is complete compatibility with adjacent elements. Although some writers have doubted the necessity for the complete satisfaction of compatibility away from the reference nodes, provided the displacement pattern is capable of assuming certain uniform strain states, the desirability of complete compatibility is not in question. The displacement fields suggested in this note satisfy complete compatibility.


2020 ◽  
Vol 28 (3) ◽  
pp. 230949902096612
Author(s):  
Jian Yu ◽  
Chao Zhang ◽  
Wen-Ming Chen ◽  
Dahang Zhao ◽  
Pengfei chu ◽  
...  

Purpose: Implant loosening in tibia after primary total ankle replacement (TAR) is one of the common postoperative problems in TAR. Innovations in implant structure design may ideally reduce micromotion at the bone–implant interface and enhance the bone-implant fixation and initial stability, thus eventually prevents long-term implant loosening. This study aimed to investigate (1) biomechanical characteristics at the bone–implant interface and (2) the influence of design features, such as radius, height, and length. Methods: A total of 101 finite-element models were created based on four commercially available implants. The models predicted micromotion at the bone–implant interface, and we investigated the impact of structural parameters, such as radius, length, and height. Results: Our results suggested that stem-type implants generally required the highest volume of bone resection before implantation, while peg-type implants required the lowest. Compared with central fixation features (stem and keel), peripherally distributed geometries (bar and peg) were associated with lower initial micromotions. The initial stability of all types of implant design can be optimized by decreasing fixation size, such as reducing the radius of the bars and pegs and lowering the height. Conclusion: Peg-type tibial implant design may be a promising fixation method, which is required with a minimum bone resection volume and yielded minimum micromotion under an extreme axial loading scenario. Present models can serve as a useful platform to build upon to help physicians or engineers when making incremental improvements related to implant design.


Author(s):  
Mohammed Abusaad Siddiqui ◽  
Sudheer N ◽  
Dulala Vikram Raj ◽  
Aditi Chintamani Sabnis ◽  
Alluru Amrutesh ◽  
...  

The treatment modality for completely edentulous arches has shifted from complete dentures to dental implants during the last 15-20 years. Tilting of implants has reduced the concern of resorbed posterior ridges in completely edentulous patients with “All-on-four” and “All-on-six” concept of dental implants. The purpose of this study is to compare the biomechanical behaviour of the “All-on-four”, “All-on-six” models with tilted distal implants at different angulations of 30 and 45 ° with four parallel placed implant-supported fixed prosthesis, and six parallel placed implant-supported fixed prosthesis models as controls using three-dimensional finite element analysis. The results showed that in all the models, in cancellous bone, cortical bone, implant and prosthesis – “All-on-four” model with distal implants tilted at an angulation of 30° showed stress values less than or equivalent to all the other models except on the implant in the presence of cantilever and on prosthesis during full mouth biting load where maximum stresses were observed. The study shows that All-on-four concept with tilted distal implants at an angulation of 30° showed stress values favourable for the rehabilitation of completely edentulous maxilla, but the presence of cantilever remains an area of concern.


Sign in / Sign up

Export Citation Format

Share Document