Effect of femtosecond and ER:YAG laser systems on shear bond strength of enamel surface and morphological changes

Author(s):  
Semanur Özüdoğru ◽  
Firdevs Kahvecioğlu ◽  
Gül Tosun ◽  
Yasemin Gündoğdu ◽  
Hamdi Şükür Kılıç
Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2093
Author(s):  
Jan Kiryk ◽  
Jacek Matys ◽  
Anna Nikodem ◽  
Karolina Burzyńska ◽  
Kinga Grzech-Leśniak ◽  
...  

We sought to evaluate the effects of Er:YAG laser (LightTouch, LightInstruments, Israel) conditioning on enamel roughness and shear bond strength of orthodontic brackets on enamel. Eighteen human molars (n = 9) and premolars (n = 9), were divided into 3 groups depending on the enamel conditioning method; Er:YAG laser (G1, n = 6), conventional etching with 37% orthophosphoric acid (G2, n = 6), Er:YAG laser combined with conventional etching (G3, n = 6). Er:YAG laser parameters were as follows: energy: 100 mJ, frequency: 10 Hz, exposure time: 10 s, applicator diameter: 600 μm, fluence: 35.37 J/cm2, distance: 1 mm away from a tooth, cooling: 80%. An MTS 858 MiniBionix® machine was used to determine the shear bond strength (MTS System, Eden Prairie, MN, USA). The enamel structure was assessed using X-ray microtomography (SkyScan 1172, Bruker, Kontich, Belgium). The highest values of shear bond strength were obtained in the G3 group (9.23 ± 2.38 MPa) and the lowest values in the G2 group (6.44 ± 2.11 MPa) (p < 0.05). A significant change in the enamel surface was noted after applying laser, reaching up to 9% of enamel thickness, which was not observed in the etched samples. Moreover, the Er:YAG laser-irradiated enamel surface was characterized by the greatest roughness. The combined use of an Er:YAG laser with a conventional etching improves the adhesion of composite materials to the tooth.


2013 ◽  
Vol 31 (10) ◽  
pp. 486-491 ◽  
Author(s):  
Tolga Topcuoglu ◽  
Ridvan Oksayan ◽  
K. Ebru Ademci ◽  
Merve Goymen ◽  
Serdar Usumez ◽  
...  

2020 ◽  
Vol 38 (3) ◽  
pp. 160-166 ◽  
Author(s):  
Thomas Knaup ◽  
Heike Korbmacher-Steiner ◽  
Andreas Braun ◽  
Johannes-Simon Wenzler ◽  
Isabel Knaup ◽  
...  

Author(s):  
Huimin Fang ◽  
Caitian Teng ◽  
Pengfei Lu ◽  
Yang Cao ◽  
Qing Yu

2014 ◽  
Vol 25 (6) ◽  
pp. 519-523 ◽  
Author(s):  
Erica Moreno Zanconato-Carvalho ◽  
João Felipe Bruniera ◽  
Natália Spadini de Faria ◽  
Vivian Colucci ◽  
Danielle Cristine Messias

Surface treatment of dentin before the bleaching procedure may affect its permeability and influence the bond strength of restorative materials. This study evaluated the influence of surface treatment before the bleaching on shear bond strength (SBT) of restorative materials to intracoronal dentin. Dentin slabs were subjected to surface treatment: no bleaching (control - CON), no surface treatment + bleaching (HP), 37% phosphoric acid + bleaching (PA) and Er:YAG laser + bleaching (L). After the bleaching procedure, specimens (n=10) were restored with: microhybrid composite resin (MH), flowable composite resin (F), and resin-modified glass-ionomer cement (RMGIC). The shear test was carried out. ANOVA and Tukey's test (α=0.05) showed significant difference for surface treatment and restorative materials (p<0.05). CON presented higher STB and was statistically different from HP (p<0.05). PA and L showed intermediate values and were statistically similar to CON and HP (p>0.05). STB for MH and F were higher than RMGIC (p<0.05), and did not differ from each other (p>0.05). The surface treatments with phosphoric acid and Er:YAG laser before the bleaching procedure provided shear bond strength at the same level of unbleached dentin and the composite resins presented superior bond strength to the intracoronal dentin.


10.2341/05-13 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 212-218 ◽  
Author(s):  
A. E. Souza-Gabriel ◽  
F. L. B. Amaral ◽  
J. D. Pécora ◽  
R. G. Palma-Dibb ◽  
S. A. M. Corona

Clinical Relevance Er:YAG laser adversely affected the adhesion of resin-modified glass ionomer cements to tooth structure and cannot be considered an alternative technique to the conventional turbine handpiece.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Ruo-qiao Han ◽  
Kai Yang ◽  
Ling-fei Ji ◽  
Chen Ling

Objective. The aim of this study was to compare the recycling of deboned ceramic brackets via an Er:YAG laser or via the traditional chairside processing methods of flaming and sandblasting; shear bond strength and morphological changes were evaluated in recycled brackets versus new brackets.Materials and Methods. 3M Clarity Self-Ligating Ceramic Brackets with a microcrystalline base were divided into groups subjected to flaming, sandblasting, or exposure to an Er:YAG laser. New ceramic brackets served as a control group. Shear bond strengths were determined with an Electroforce test machine and tested for statistical significance through analysis of variance. Morphological examinations of the recycled ceramic bracket bases were conducted with scanning electron microscopy and confocal laser scanning microscopy. Residue on the bracket base was analyzed with Raman spectroscopy.Results. Faded, dark adhesive was left on recycled bracket bases processed via flaming. Adhesive was thoroughly removed by both sandblasting and exposure to an Er:YAG laser. Compared with new brackets, shear bond strength was lower after sandblasting (p<0.05), but not after exposure to an Er:YAG laser. The Er:YAG laser caused no damage to the bracket.Conclusion. Er:YAG lasers effectively remove adhesive from the bases of ceramic brackets without damaging them; thus, this method may be preferred over other recycling methods.


2015 ◽  
Vol 48 (10) ◽  
pp. 978-984 ◽  
Author(s):  
Yuan-Yuan Kong ◽  
Yi Chen ◽  
Rui Shen ◽  
Qian-Zhou Jiang ◽  
Min-Le Chen

2007 ◽  
Vol 77 (1) ◽  
pp. 117-124 ◽  
Author(s):  
Güvenç Basaran ◽  
Törün Özer ◽  
Nükhet Berk ◽  
Orhan Hamamcı

Abstract Objective: To test the shear bond strength, surface characteristics, and fracture mode of brackets that are bonded to enamel etched with an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser operated at different power outputs: 0.5 W, 1 W, and 2 W. Materials and Methods: Human premolars that had been extracted for orthodontic purposes were used. Enamel was etched with an Er,Cr:YSGG laser system operated at one of three power outputs or with orthophosphoric acid. Results: The shear bond strength associated with the 0.5-W laser irradiation was significantly less than the strengths obtained with the other irradiations. Both the 1-W and 2-W laser irradiations were capable of etching enamel in the same manner. This finding was confirmed by scanning electron microscopy examination. The evaluation of adhesive-remnant-index scores demonstrated no statistically significant difference in bond failure site among the groups, except for the 0.5-W laser–etched group. Generally, more adhesive was left on the enamel surface with laser irradiation than with acid etching. Conclusion: The mean shear bond strength and enamel surface etching obtained with an Er,Cr: YSGG laser (operated at 1 W or 2 W for 15 seconds) is comparable to that obtained with acid etching.


Sign in / Sign up

Export Citation Format

Share Document