Methods for the determination of the static accuracy and linearity of electron-beam test systems

1992 ◽  
Vol 16 (1-4) ◽  
pp. 233-238 ◽  
Author(s):  
R. Lackmann ◽  
G. Weichert
Keyword(s):  
1987 ◽  
Vol 7 (2-4) ◽  
pp. 201-207 ◽  
Author(s):  
D.J. Machin ◽  
D.W. Ranasinghe ◽  
G. Proctor

Author(s):  
J. C. Ingram ◽  
P. R. Strutt ◽  
Wen-Shian Tzeng

The invisibility criterion which is the standard technique for determining the nature of dislocations seen in the electron microscope can at times lead to erroneous results or at best cause confusion in many cases since the dislocation can still show a residual image if the term is non-zero, or if the edge and screw displacements are anisotropically coupled, or if the dislocation has a mixed character. The symmetry criterion discussed below can be used in conjunction with and in some cases supersede the invisibility criterion for obtaining a valid determination of the nature of the dislocation.The symmetry criterion is based upon the well-known fact that a dislocation, because of the symmetric nature of its displacement field, can show a symmetric image when the dislocation is correctly oriented with respect to the electron beam.


Author(s):  
Marc J.C. de Jong ◽  
Wim M. Busing ◽  
Max T. Otten

Biological materials damage rapidly in the electron beam, limiting the amount of information that can be obtained in the transmission electron microscope. The discovery that observation at cryo temperatures strongly reduces beam damage (in addition to making it unnecessaiy to use chemical fixatives, dehydration agents and stains, which introduce artefacts) has given an important step forward to preserving the ‘live’ situation and makes it possible to study the relation between function, chemical composition and morphology.Among the many cryo-applications, the most challenging is perhaps the determination of the atomic structure. Henderson and co-workers were able to determine the structure of the purple membrane by electron crystallography, providing an understanding of the membrane's working as a proton pump. As far as understood at present, the main stumbling block in achieving high resolution appears to be a random movement of atoms or molecules in the specimen within a fraction of a second after exposure to the electron beam, which destroys the highest-resolution detail sought.


1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S95-S112 ◽  
Author(s):  
A. H. W. M. Schuurs

ABSTRACT Various techniques for sensitising erythrocytes and latex particles with gonadotrophins, particularly with HCG, are described. The haemagglutination inhibition reactions are generally interpreted by means of »erythrocyte settling patterns«. By a new method of evaluating these patterns a relatively precise quantitative determination is possible. Latex agglutination inhibition reactions on slides are particularly suitable as rapid qualitative tests. In cases where the maximum attainable sensitivity of the agglutination inhibition tests is insufficient, e. g. for determining LH concentrations in urine, the hormone in the test fluid has to be concentrated or extracted. An alternative method is a modified haemagglutination inhibition test for large volumes which is applicable to unconcentrated urine. Due to non-specific inhibitions the above-mentioned tests cannot be applied to unprocessed serum. Agglutination inhibition tests with HCG are already well advanced, pregnancy diagnosis being their main application. Now that highly purified HCG is available, a satisfactory specificity for these tests can be attained. If the immune system for HCG is used for estimating LH, it has to meet additional specificity requirements. Furthermore, the measure of cross-reaction and the choice of standard merit special attention. Finally, a literature survey is given of test systems in which LH and FSH were used as antigens.


2009 ◽  
Vol 156-158 ◽  
pp. 487-492 ◽  
Author(s):  
M.V. Zamoryanskaya

In this paper the new method for determination of luminescent centers concentration are discussed. While the possibility of electron traps determination and definition of its activation energy are suggested. The cathodoluminescent (CL) method was used. The determination of luminescent centers concentration in silicon oxide is based on the measurements of dependences of CL intensity on electron beam current. The presence and energy of activation of electron traps were studied by measurement of rise time and decay of luminescent band during the stationary irradiation of silica by electron beam.


2012 ◽  
Vol 30 (8) ◽  
pp. 714-723 ◽  
Author(s):  
Hakan Ozkan ◽  
Derya Yanmis ◽  
Mehmet Karadayi ◽  
Tugba Bal ◽  
Ozlem Baris ◽  
...  
Keyword(s):  
E Coli ◽  

Sign in / Sign up

Export Citation Format

Share Document