Response of human cancellous bone to identically structured commercially pure titanium and cobalt chromium alloy porous-coated cylinders

1993 ◽  
Vol 14 (2) ◽  
pp. 101-115 ◽  
Author(s):  
A.A. Hofmann
2011 ◽  
Vol 12 (3) ◽  
pp. 179-186
Author(s):  
Adriana Cristina Zavanelli ◽  
Recardo Alexandre Zavanelli ◽  
José Everaldo de Aquino Souza ◽  
Nelson Renato França Alves da Silva ◽  
Paulo Guilherme Coelho ◽  
...  

ABSTRACT Aim There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium- titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut. How to cite this article Souza JEdA, da Silva NRFA, Coelho PG, Zavanelli AC, Ferracioli RCSR, Zavanelli RA. Retention Strength of Cobalt-Chromium vs Nickel-Chromium Titanium vs CP Titanium in a Cast Framework Association of Removable Partial Overdenture. J Contemp Dent Pract 2011;12(3):179-186.


2010 ◽  
Vol 21 (6) ◽  
pp. 515-519 ◽  
Author(s):  
Gustavo Augusto Seabra Barbosa ◽  
Flávio Domingues das Neves ◽  
Maria da Gloria Chiarello de Mattos ◽  
Renata Cristina Silveira Rodrigues ◽  
Ricardo Faria Ribeiro

This study compared vertical and passive fit of one-piece cast frameworks made with 3 different materials: commercially pure titanium (CP Ti - G1), cobalt-chromium alloy (Co-Cr - G2) and nickel-chromium-titanium alloy (Ni-Cr-Ti - G3). Fifteen frameworks were obtained simulating bars for fixed prosthesis in a model with 5 implants. The passive and vertical fit of the framework interface was measured using an optical microscope at ×30 magnification. Data were statistically analyzed by ANOVA and LSD tests (α=0.05). Mean and standard deviation values for passive fit and vertical fit were, respectively: G1 [472.49 (109.88) µm and 29.9 (13.24) µm], G2 [584.84 (120.20) µm and 27.05 (10.30) µm], and G3 [462.70 (179.18) µm and 24.95 (11.14) µm]. For vertical fit, there were no significant differences among G1, G2 and G3 (p=0.285). There were no significant differences for passive fit between G1 and G3 (p=0.844), but both differed significantly from G2 (p=0.028 and p=0.035, respectively), which showed the highest misfit values. It may be concluded that the vertical fit of frameworks was not affected by the tested materials, and that one-piece cast frameworks resulted in inadequate passive fit. The Co-Cr alloy presented the worst values for passive fit.


Alloy Digest ◽  
1979 ◽  
Vol 28 (12) ◽  

Abstract RMI 0.2% Pd is a grade of commercially pure titanium to which up to 0.2% palladium has been added. It has a guaranteed minimum yield strength of 40,000 psi with good ductility and formability. It is recommended for corrosion resistance in the chemical industry and other places where the environment is mildly reducing or varies between oxidizing and reducing. The alloy has improved resistance to crevice corrosion at low pH and elevated temperatures. This datasheet provides information on composition, physical properties, elasticity, tensile properties, and bend strength. It also includes information on corrosion resistance as well as forming, heat treating, machining, joining, and surface treatment. Filing Code: Ti-74. Producer or source: RMI Company.


Alloy Digest ◽  
2020 ◽  
Vol 69 (6) ◽  

Abstract UPM CP Titanium Grade 3 (UNS R50550) is an unalloyed commercially pure titanium that exhibits moderate strength (higher strength than that of Titanium Grade 2), along with excellent formability and corrosion resistance. It offers the highest ASME allowable design stress of any commercially pure grade of titanium, and can be used in continuous service up to 425 °C (800 °F) and in intermittent service up to 540 °C (1000 °F). This datasheet provides information on composition, physical properties, and elasticity. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: Ti-167. Producer or source: United Performance Metals.


Sign in / Sign up

Export Citation Format

Share Document