scholarly journals Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator

1994 ◽  
Vol 23 (6) ◽  
pp. 1342-1355 ◽  
Author(s):  
Charles D. Swerdlow ◽  
Peng-Sheng Chen ◽  
Robert M. Kass ◽  
Jean R. Allard ◽  
C.Thomas Peter
2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
P Insulander ◽  
C Carnlof ◽  
M Jensen-Urstad ◽  
K Schenck-Gustafsson

Abstract Background Highly symptomatic palpitations are common, particularly in women, and may cause disturbing symptoms including anxiety, depression, and decreased health related quality of life. Palpitation in this context has been considered generally benign and caused by premature atrial or ventricular beats or stress-induced sinus tachycardia. However, how often arrhythmias of clinical importance such as atrial fibrillation and supraventricular or ventricular tachycardia is the cause is unknown. Purpose To evaluate to what extent symptomatic palpitation in women is caused by clinically important arrhythmias. Methods A new Swedish digital technique was used. The system uses a well-validated algorithm to analyze heart rhythm (both thumbs and chest recordings), is connected to the user's smartphone and provides immediate response to the user. The result is simultaneously available for the supervising physician. In cases of non-benign arrhythmias, the result was also analyzed manually. In all, 909 women (age 56±11 years) with palpitations causing anxiety were included. ECG was recorded twice a day and at symptoms for 60 days. Participants with known atrial fibrillation were excluded. Results In all, 6 861 ECG recordings were done due to symptomatic palpitation. Underlying heart rhythms were as follows: normal sinus rhythm (73%), sinus tachycardia (12%), premature atrial beats or ventricular beats (7%), atrial fibrillation (4%), benign sinus bradycardia and second-degree AV block type 1 (4%), and supraventricular tachycardia (1%). In 1% of recordings, quality was too poor for analysis. No ventricular tachycardia was recorded. In all, 19 women with previously undiagnosed atrial fibrillation and 12 women with undiagnosed supraventricular tachycardia were found. Conclusions In the great majority of episodes causing symptomatic palpitation in women, the underlying arrhythmia is benign. However, in 5% previously undiagnosed atrial fibrillation or supraventricular tachycardia were found.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
M Ziacchi ◽  
A Capucci ◽  
G Tola ◽  
M Scaglione ◽  
A D"onofrio ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. BACKGROUND The Wearable Cardioverter Defibrillators (WCD) has been used extensively in Italy since 2015, following long years of experience in other countries. This technology provides temporary protection from Sudden Cardiac Death (SCD) for patients with an evolving risk profile that may not yet be eligible for an Implantable Cardioverter Defibrillator (ICD). Collecting national data on use of the device can help build a picture that will enable an understanding on how to use the WCD appropriately in the future. PURPOSE Our purpose has been to investigate WCD usage on a nationwide level. This is in terms of target population, average wear time, patient compliance, diagnosed and treated arrhythmic events and patient outcome once they stopped wearing the device. METHODS WEAR-ITA is a nationwide, multi-centre retrospective observational project. Patient data was retrospectively collected from the Italian hospitals that agreed to take part in the data collection for all patients fitted with a WCD between April 2015 to May 2018. All data refers to the range from the first day of wear until the end of use. RESULTS We collected data for 411 patients from 15 (75%) Italian regions. WCD use among the different regions was heterogeneous with a median of 0.5 (0.2-1.2) WCD wore/105 inhabitants. The mean age of the population was 55(±14) and the majority of patients were male (79%). Main WCD indication was non-ischemic cardiomyopathy with reduced ejection fraction (51%), ischemic etiology with severe systolic dysfunction (31%), uncertain or unidentified diagnosis (10%) that then revealed to be predominantly channelopathies or myocarditis and after ICD extraction (8%). Patients wore the WCD for a median of 59 (33-90) days and the median daily weartime was 23 (22,7-23,8) hours. In 15 patients (4%), the WCD recorded non sustained ventricular tachycardia (VT), 10  patients (2%) had hemodynamically well-tolerated sustained VT not needing a shock. 8 patients (2%) received effective appropriate shocks. Time to episodes were respectively 61 (14-61) days for non-sustained VT and 28 (19-70) days for VT/VF. 2 patients (0.5%) received inappropriate shocks for sinus tachycardia and atrial fibrillation (AF) respectively. WCD recorded new onset of supra ventricular tachycardia episodes in 12 patients (3%) and of atrial fibrillation (AF) in 7 patients (2%). 7 patients (2%) died while wearing WCD; none of them from SCD. At the end of the WCD use, 195 patients (47%) did not receive an ICD while 209 patients (51%)were implanted. CONCLUSIONS WCD is an effective therapy for the treatment of SCD with a very low complication rates. The indication and penetration in Italy is quite heterogeneous. The patient’s compliance is high over time. The incidence of appropriate shock is not negligible; only half of patients, who wore WCD, received an ICD. There is however still a requirement to conduct further randomized trials to understand which patients could most benefit from the use of WCD. Abstract Figure. Wereable Cardioverter Defibrillator


scholarly journals POSTERS (2)96CONTINUOUS VERSUS INTERMITTENT MONITORING FOR DETECTION OF SUBCLINICAL ATRIAL FIBRILLATION IN HIGH-RISK PATIENTS97HIGH DAY-TO-DAY INTRA-INDIVIDUAL REPRODUCIBILITY OF THE HEART RATE RESPONSE TO EXERCISE IN THE UK BIOBANK DATA98USE OF NOVEL GLOBAL ULTRASOUND IMAGING AND CONTINUEOUS DIPOLE DENSITY MAPPING TO GUIDE ABLATION IN MACRO-REENTRANT TACHYCARDIAS99ANTICOAGULATION AND THE RISK OF COMPLICATIONS IN PATIENTS UNDERGOING VT AND PVC ABLATION100NON-SUSTAINED VENTRICULAR TACHYCARDIA FREQUENTLY PRECEDES CARDIAC ARREST IN PATIENTS WITH BRUGADA SYNDROME101USING HIGH PRECISION HAEMODYNAMIC MEASUREMENTS TO ASSESS DIFFERENCES IN AV OPTIMUM BETWEEN DIFFERENT LEFT VENTRICULAR LEAD POSITIONS IN BIVENTRICULAR PACING102CAN WE PREDICT MEDIUM TERM MORTALITY FROM TRANSVENOUS LEAD EXTRACTION PRE-OPERATIVELY?103PREVENTION OF UNECESSARY ADMISSIONS IN ATRIAL FIBRILLATION104EPICARDIAL CATHETER ABLATION FOR VENTRICULAR TACHYCARDIA ON UNINTERRUPTED WARFARIN: A SAFE APPROACH?105HOW WELL DOES THE NATIONAL INSTITUTE OF CLINICAL EXCELLENCE (NICE) GUIDENCE ON TRANSIENT LOSS OF CONSCIOUSNESS (T-LoC) WORK IN A REAL WORLD? AN AUDIT OF THE SECOND STAGE SPECIALIST CARDIOVASCULAT ASSESSMENT AND DIAGNOSIS106DETECTION OF ATRIAL FIBRILLATION IN COMMUNITY LOCATIONS USING NOVEL TECHNOLOGY'S AS A METHOD OF STROKE PREVENTION IN THE OVER 65'S ASYMPTOMATIC POPULATION - SHOULD IT BECOME STANDARD PRACTISE?107HIGH-DOSE ISOPRENALINE INFUSION AS A METHOD OF INDUCTION OF ATRIAL FIBRILLATION: A MULTI-CENTRE, PLACEBO CONTROLLED CLINICAL TRIAL IN PATIENTS WITH VARYING ARRHYTHMIC RISK108PACEMAKER COMPLICATIONS IN A DISTRICT GENERAL HOSPITAL109CARDIAC RESYNCHRONISATION THERAPY: A TRADE-OFF BETWEEN LEFT VENTRICULAR VOLTAGE OUTPUT AND EJECTION FRACTION?110RAPID DETERIORATION IN LEFT VENTRICULAR FUNCTION AND ACUTE HEART FAILURE AFTER DUAL CHAMBER PACEMAKER INSERTION WITH RESOLUTION FOLLOWING BIVENTRICULAR PACING111LOCALLY PERSONALISED ATRIAL ELECTROPHYSIOLOGY MODELS FROM PENTARAY CATHETER MEASUREMENTS112EVALUATION OF SUBCUTANEOUS ICD VERSUS TRANSVENOUS ICD- A PROPENSITY MATCHED COST-EFFICACY ANALYSIS OF COMPLICATIONS & OUTCOMES113LOCALISING DRIVERS USING ORGANISATIONAL INDEX IN CONTACT MAPPING OF HUMAN PERSISTENT ATRIAL FIBRILLATION114RISK FACTORS FOR SUDDEN CARDIAC DEATH IN PAEDIATRIC HYPERTROPHIC CARDIOMYOPATHY: A SYSTEMATIC REVIEW AND META-ANALYSIS115EFFECT OF CATHETER STABILITY AND CONTACT FORCE ON VISITAG DENSITY DURING PULMONARY VEIN ISOLATION116HEPATIC CAPSULE ENHANCEMENT IS COMMONLY SEEN DURING MR-GUIDED ABLATION OF ATRIAL FLUTTER: A MECHANISTIC INSIGHT INTO PROCEDURAL PAIN117DOES HIGHER CONTACT FORCE IMPAIR LESION FORMATION AT THE CAVOTRICUSPID ISTHMUS? INSIGHTS FROM MR-GUIDED ABLATION OF ATRIAL FLUTTER118CLINICAL CHARACTERISATION OF A MALIGNANT SCN5A MUTATION IN CHILDHOOD119RADIOFREQUENCY ASSOCIATED VENTRICULAR FIBRILLATION120CONTRACTILE RESERVE EXPRESSED AS SYSTOLIC VELOCITY DOES NOT PREDICT RESPONSE TO CRT121DAY-CASE DEVICES - A RETROSPECTIVE STUDY USING PATIENT CODING DATA122PATIENTS UNDERGOING SVT ABLATION HAVE A HIGH INCIDENCE OF SECONDARY ARRHYTHMIA ON FOLLOW UP: IMPLICATIONS FOR PRE-PROCEDURE COUNSELLING123PROGNOSTIC ROLE OF HAEMOGLOBINN AND RED BLOOD CELL DITRIBUTION WIDTH IN PATIENTS WITH HEART FAILURE UNDERGOING CARDIAC RESYNCHRONIZATION THERAPY124REMOTE MONITORING AND FOLLOW UP DEVICES125A 20-YEAR, SINGLE-CENTRE EXPERIENCE OF IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICD) IN CHILDREN: TIME TO CONSIDER THE SUBCUTANEOUS ICD?126EXPERIENCE OF MAGNETIC REASONANCE IMAGING (MEI) IN PATIENTS WITH MRI CONDITIONAL DEVICES127THE SINUS BRADYCARDIA SEEN IN ATHLETES IS NOT CAUSED BY ENHANCED VAGAL TONE BUT INSTEAD REFLECTS INTRINSIC CHANGES IN THE SINUS NODE REVEALED BY I (F) BLOCKADE128SUCCESSFUL DAY-CASE PACEMAKER IMPLANTATION - AN EIGHT YEAR SINGLE-CENTRE EXPERIENCE129LEFT VENTRICULAR INDEX MASS ASSOCIATED WITH ESC HYPERTROPHIC CARDIOMYOPATHY RISK SCORE IN PATIENTS WITH ICDs: A TERTIARY CENTRE HCM REGISTRY130A DGH EXPERIENCE OF DAY-CASE CARDIAC PACEMAKER IMPLANTATION131IS PRE-PROCEDURAL FASTING A NECESSITY FOR SAFE PACEMAKER IMPLANTATION?

EP Europace ◽  
2016 ◽  
Vol 18 (suppl 2) ◽  
pp. ii36-ii47
Author(s):  
T. Philippsen ◽  
M. Orini ◽  
C.A. Martin ◽  
E. Volkova ◽  
J.O.M. Ormerod ◽  
...  

2021 ◽  
Vol 10 (7) ◽  
pp. 1456
Author(s):  
Carlo Lavalle ◽  
Michele Magnocavallo ◽  
Martina Straito ◽  
Luca Santini ◽  
Giovanni Battista Forleo ◽  
...  

Transcatheter ablation was increasingly and successfully used to treat symptomatic drug refractory patients affected by supraventricular arrhythmias. Antiarrhythmic drug treatment still plays a major role in patient management, alone or combined with non-pharmacological therapies. Flecainide is an IC antiarrhythmic drug approved in 1984 from the Food and Drug Administration for the suppression of sustained ventricular tachycardia and later for acute cardioversion of atrial fibrillation and for sinus rhythm maintenance. Currently, flecainide is mostly used for sinus rhythm maintenance in atrial fibrillation (AF) patients without structural cardiomyopathy although recent studies enrolling different patient populations have demonstrated a good effectiveness and safety profile. How should we interpret the results of the CAST after the latest evidence? Is it possible to expand the indications of flecainide, and therefore, its use? This review aims to highlight the main characteristics of flecainide, as well as its optimal clinical use, delineating drug indications and contraindications and appropriate monitoring, based on the most recent evidence.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
F Guerra ◽  
L Pimpini ◽  
M Flori ◽  
D Contadini ◽  
G Stronati ◽  
...  

Abstract Background Sacubitril/valsartan, the first combined angiotensin receptor-neprilysin inhibitor, has demonstrated a significant benefit compared to angiotensin inhibitor in decreasing ventricular arrhythmias and appropriate implantable cardioverter defibrillator (ICD) shocks in patients with heart failure with reduced ejection fraction (HFrEF). At present, there is no study which evaluates the effect of sacubitril/valsartan on the supraventricular arrhythmic burden in HFrEF patients with an ICD or cardiac resynchronisation therapy-defibrillator (CRT-D) and remote monitoring. Purpose To evaluate the effect of sacubitril/valsartan on the supraventricular arrhythmic burden in HFrEF patients with an ICD or CRTD and remote monitoring. Methods The SAVETHERHYTHM ((SAacubitril Valsartan rEal-world registry evaluating THE arRHYTHMia burden in HFrEF patients with implantable cardioverter defibrillator) is a multicentre, observational, prospective registry enrolling all patients with HFrEF, ICD or CRT-D actively followed through remote monitoring and starting treatment with sacubitril/valsartan. All patients are followed-up for at least one year after sacubitril/valsartan start. The primary endpoint is the mean number of sustained atrial tachycardia or atrial fibrillation (AT/AF) episodes per month. Secondary endpoints include the total burden of AT/AF (defined as the percentage of time in AT/AF per day), the mean number of premature ventricular contractions (PVC) per hour and the percentage of biventricular pacing per day (in patients with CRT-D). All primary and secondary endpoints are collected through remote monitoring. Results At the time of the first ad interim analysis, 60 patients (85.2% male, age 69±10 years) were consecutively enrolled. After treatment with sacubitril/valsartan, patients with at least one episode of AT/AF per month decreased from 32.8% to 21.3% (p=0.015). A significant decrease in number of AT/AF episodes (from 4.3 to 1.2 per year), in AT/AF burden (from 12% to 9%) and in number of PVC (from 83 to 74 per hour) were seen in patients with a previous diagnosis of paroxysmal or persistent AF (n=15; all p<0.05). Patients with permanent AF (n=7) experienced no benefits from sacubitril/valsartan therapy in terms of arrhythmic burden reduction. Patients with no previous history of AF (n=38) showed a decrease in number of AT/AF episodes (from 2.0 to 0.8 per year) and in number of PVC (from 77 to 49 per hour, all p<0.05). No new diagnosis of clinical AF was made after starting treatment with sacubitrl/valsartan, and patients with subclinical AT/AF episodes decreased from 8% to 3%. Conclusions Preliminary data suggest that therapy with sacubitril/valsartan could decrease arrhythmic burden in patients with non-permanent AF and reduce subclinical AT/AF episodes in patients with no history of AF. No positive effect has been noted in patients with permanent AF. Funding Acknowledgement Type of funding source: None


Author(s):  
Nadezhda I. Kuprina ◽  
Ekaterina V. Ulanovskaya ◽  
Viktor V. Shilov ◽  
Dina N. Serdyukova

Currently, there are many consequences of the new coronavirus infection. We shall study the actual long-term consequences of this disease for population health in the coming years. It is necessary to consider concomitant chronic diseases in patients who are particularly dangerous in the post-COVID period. Vibration disease is one of the leading occupational pathologies in the Russian Federation. Symptoms of vibration disease are vegetative-vascular disorders, cold, cyanosis, paresthesia, violation of regional blood circulation of the extremities. As is known from numerous sources, the defeat of the cardiovascular system (CVS) against the background of COVID-19 infection occurs through angiotensin-converting enzyme (ACE-2) receptors, which presents in large numbers in the endothelium of veins and arteries. The study aims to research hemodynamics features in patients with vibration disease after a new coronavirus infection. In the clinic of occupational pathology, the researchers examined 28 patients with a previously established diagnosis of VD after a coronavirus infection. We did a Holter ECG, ultra-sound examination of the arteries and veins of the upper extremities. Arrhythmias in the form of supraventricular extrasystoles, paroxysms of atrial fibrillation, positional sinus tachycardia occur in patients with VB after a new coronavirus infection on an ECG and daily monitoring of the ECG by Holter. As is known, cardiac arrhythmias are essential in the development of acute and chronic vascular pathology, characterized by a decrease in arterial blood filling and changes. Ultrasound of the vessels of the upper extremities revealed moderate expansion of the radial and ulnar veins, insufficiency of the valve apparatus during functional tests, increased venous outflow. There was also an increase in the indicators of peripheral vascular resistance, which indicates violations of the tonic properties of the vessels of the upper extremities and violations of vasodilation. Scientists identified violations of the tonic properties of blood vessels in patients with vibration disease in the post-COVID period on ultrasound, arrhythmias in the form of supraventricular extrasys-toles, paroxysms of atrial fibrillation, positional sinus tachycardia on daily ECG monitoring.


2016 ◽  
Vol 5 (2) ◽  
pp. 136 ◽  
Author(s):  
Alessio Galli ◽  
Francesco Ambrosini ◽  
Federico Lombardi ◽  
◽  
◽  
...  

Holter monitors are tools of proven efficacy in diagnosing and monitoring cardiac arrhythmias. Despite the fact their use is widely prescribed by general practitioners, little is known about their evolving role in the management of patients with cryptogenic stroke, paroxysmal atrial fibrillation, unexplained recurrent syncope and risk stratification in implantable cardioverter defibrillator or pacemaker candidates. New Holter monitoring technologies and loop recorders allow prolonged monitoring of heart rhythm for periods from a few days to several months, making it possible to detect infrequent arrhythmias in patients of all ages. This review discusses the advances in this area of arrhythmology and how Holter monitors have improved the clinical management of patients with suspected cardiac rhythm diseases.


Sign in / Sign up

Export Citation Format

Share Document