Calculated reduction factor of feeding cable lines

2022 ◽  
pp. 19-48
Author(s):  
Ljubivoje M. Popović
Keyword(s):  
2020 ◽  
Vol 30 (30) ◽  
pp. 43-49
Author(s):  
Ranko Jasika ◽  
Jovan Mrvić ◽  
Ninoslav Simić ◽  
Momčilo Petrović

The procedure for determining the reduction factor for 110 kV feeding cable lines based on the measurement results is presented in this paper. The obtained results were compared with the values obtained by cable line modeling by ATP/EMTP software tool. The values obtained for reduction factor are compared, as well as the values of induced voltage in the cable sheath. The obtained results show a fairly good agreement between the simulation model and measurements. In the created model, the influence of soil resistivity and conductors arrangement on the values of the reduction factor were analyzed. It has been shown that their combined impact can be significant.


2014 ◽  
Vol 27 (1) ◽  
pp. 25-39 ◽  
Author(s):  
Ljubivoje Popovic

The paper presents the method for determination of ground fault current distribution in the cases when feeding cable lines are passing through urban and/or suburban areas, or when many relevant data are uncertain, or completely unknown. The problem appears as a consequence of the fact that many of surrounding urban installations are situated under the surface of the ground and cannot be visually determined or verified. On the basis of on site measurements, the developed method enables compensation of all deficiencies of the relevant data about metal installations involved with the fluctuating magnet field appearing along and around of a power line during an unbalanced fault. The presented analytical procedure is based on the fact that certain measurable quantities cumulatively involve the inductive effects of all, known and unknown surrounding metal installations. The performed quantitative analysis points on at the significance of taking into account the existence of surrounding metal installations.


2020 ◽  
pp. 85-88 ◽  
Author(s):  
Nadezhda P. Kondratieva

The article describes the results of the study concerning the effect of the voltage level on current harmonic composition in greenhouses irradiators. It is found that its change affects the level of current harmonics of all types of the studied greenhouse irradiators. With decrease of nominal supply voltage by 10 %, the total harmonic distortion THDi decreases by 9 % for emitters equipped with high pressure sodium lamps (HPSL), by 10 % for emitters with electrode-less lamps and by 3 % for LED based emitters. With increase of nominal supply voltage by 10 %, THDi increases by 23 % for lighting devices equipped with HPSL, by 10 % for irradiators with electrode-less lamps and by 3 % for LED based emitters. Therefore, changes of supply voltage cause the least effect on the level of current harmonics of LED based emitters and then the emitters with electrode-less lamps. Change of the level of supply voltage causes the greatest effect on the level of current harmonics of HPSL based irradiators. Mathematical models of dependence of THDi on the level of supply voltage for greenhouse emitters equipped with LED, electrode-less lamps and HPSL lamps were formulated. These mathematical models may be used for calculations of total current when selecting transformers and supply cable lines for greenhouse lighting devices, for design of new or reconstruction of existing irradiation systems of greenhouse facilities, and for calculation of power losses in power supply networks of greenhouse facilities during feasibility studies for energy saving and energy efficiency increasing projects.


2016 ◽  
Vol 2016 (4) ◽  
pp. 5-7
Author(s):  
V.Yu. Rozov ◽  
◽  
P.N. Dobrodeyev ◽  
A.V. Erisov ◽  
A.O. Tkachenko ◽  
...  

2019 ◽  
Vol 85 (1(I)) ◽  
pp. 64-71 ◽  
Author(s):  
M. M. Gadenin

The cycle configuration at two-frequency loading regimes depends on the number of parameters including the absolute values of the frequencies and amplitudes of the low-frequency and high-frequency loads added during this mode, the ratio of their frequencies and amplitudes, as well as the phase shift between these harmonic components, the latter having a significant effect only with a small ratio of frequencies. Presence of such two-frequency regimes or service loading conditions for parts of machines and structures schematized by them can significantly reduce their endurance. Using the results of experimental studies of changes in the endurance of a two-frequency loading of specimens of cyclically stable, cyclically softened and cyclically hardened steels under rigid conditions we have shown that decrease in the endurance under the aforementioned conditions depends on the ratio of frequencies and amplitudes of operation low-frequency low-cycle and high-frequency vibration stresses, and, moreover, the higher the level of the ratios of amplitudes and frequencies of those stacked harmonic processes of loading the greater the effect. It is shown that estimation of such a decrease in the endurance compared to a single frequency loading equal in the total stress (strains) amplitudes can be carried out using an exponential expression coupling those endurances through a parameter (reduction factor) containing the ratio of frequencies and amplitudes of operation cyclic loads and characteristic of the material. The reduction is illustrated by a set of calculation-experimental curves on the corresponding diagrams for each of the considered types of materials and compared with the experimental data.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1374
Author(s):  
Bartosz Rozegnał ◽  
Paweł Albrechtowicz ◽  
Dominik Mamcarz ◽  
Monika Rerak ◽  
Maciej Skaza

This paper presents the skin effect impact on the active power losses in the sheathless single-core cables/wires supplying nonlinear loads. There are significant conductor losses when the current has a distorted waveform (e.g., the current supplying diode rectifiers). The authors present a new method for active power loss calculation. The obtained results have been compared to the IEC-60287-1-1:2006 + A1:2014 standard method and the method based on the Bessel function. For all methods, the active power loss results were convergent for small-cable cross-section areas. The proposed method gives smaller power loss values for these cable sizes than the IEC and Bessel function methods. For cable cross-section areas greater than 185 mm2, the obtained results were better than those for the other methods. There were also analyses of extra power losses for distorted currents compared to an ideal 50 Hz sine wave for all methods. The new method is based on the current penetration depth factor calculated for every considered current harmonics, which allows us to calculate the precise equivalent resistance for any cable size. This research is part of our work on a cable thermal analysis method that has been developed.


2021 ◽  
pp. 108128652110214
Author(s):  
Ivan Argatov

The problem of a mode I crack having multiple contacts between the crack faces is considered. In the case of small contact islands of arbitrary shapes, which are arbitrarily located inside the crack, the first-order asymptotic model for the crack opening displacement is constructed using the method of matched asymptotic expansions. The case of a penny-shaped crack has been studied in detail. A scaling hypothesis for the compliance reduction factor is formulated.