Thermal Behaviour of a Storage Tank Filled with Hot Water Produced by a Flat Plate Solar Collector Pond

Author(s):  
S.A. Betrouni ◽  
N. Bacha ◽  
A. Mansouri ◽  
M. Attek ◽  
H. Makhlouf
2017 ◽  
Author(s):  
Carola Sánchez ◽  
José Macías ◽  
Jonathan León ◽  
Geancarlos Zamora ◽  
Guillermo Soriano

Passive solar water heating (SWH) is a convenient method to meet domestic hot water requirements in rural areas, where electricity may not be available or fuel supply might be limited due to difficult access. In this work, a low-cost thermosiphon flat-plate solar collector alternative is presented. The design was purposely limited to materials and recyclable products widely available in the local market, such as Tetra Pak, plastic bottles, and polypropylene (PP) fittings and pipes. Since PP is a thermoplastic polymer, a poor heat conductor, it was necessary to ensure a suitable system isolation to obtain an optimum thermal performance, comparable to commercial solar collectors. The design was built and tested in Guayaquil, Ecuadorian coastal city. Six inexpensive temperature sensors were placed at the entrance and exit of the collector, on the flat-plate and inside the hot water storage tank. Data was recorded using an Arduino single-board computer and later analyzed with the data gathered via weather station. The implementation costs of the system are approximately US$300, the overall performance during January 2017 fluctuated between 54% and 23%, and the storage tank temperature range varied from to 46°C to 33°C. Due to its reliability and affordable cost, the SWH system is an attractive alternative to an Ecuadorian commercial solar flat plate collector, which price is set between US$600 and US$700, it has an efficiency around 60%, and the average annual storage tank temperature is 62°C.


2018 ◽  
Vol 4 (3) ◽  
pp. 25 ◽  
Author(s):  
Daniel Ferrández ◽  
Carlos Moron ◽  
Jorge Pablo Díaz ◽  
Pablo Saiz

ResumenEl actual Código Técnico de la Edificación (CTE) pone de manifiesto la necesidad de cubrir parte de la demanda energética requerida para el abastecimiento de agua caliente sanitaria y climatización de piscinas cubiertas mediante sistemas de aprovechamiento de la energía solar térmica. En este artículo se presenta una comparativa entre las dos principales tipologías de captadores solares térmicos que existen en el mercado: el captador de placa plana y el captador de tubo de vacío, atendiendo a criterios de fracción solar, diseño e integración arquitectónica. Todo ello a fin de discernir en qué circunstancias es más favorable el uso de uno u otro sistema, comparando los resultados obtenidos mediante programas de simulación con la toma de medidas in situ.AbstractThe current Technical Building Code (CTE) highlights the need to cover part of the energy demand required for the supply of hot water and heating of indoor swimming pools using solar thermal systems. This article presents a comparison between the two main types of solar thermal collectors that exist in the market: the flat plate solar collector and the vacuum tube solar collector, according to criteria of solar fraction, design and architectural integration. All of this in order to discern in what circumstances the use of one or the other system is more favourable, comparing the results obtained through simulation programs with the taking of measurements in situ.


2017 ◽  
Vol 53 (4) ◽  
pp. 303-305
Author(s):  
Sh. I. Klychev ◽  
O. Kh. Nizomov ◽  
D. E. Kadyrgulov

2019 ◽  
Vol 97 (10) ◽  
pp. 1115-1124 ◽  
Author(s):  
Khosro Lari ◽  
Ali Tarokh ◽  
Mohammad Naghizadeh

A standard thermal solar collector can be used for both hot water production and air heating purposes. Gas-filled solar collectors represent a new emerging design approach with enhanced characteristics. In this research, numerical modeling is utilized to study radiative effects of the participating gases on the performance of solar collectors. The coupled radiative–convective heat transfer in the solar collector is considered and the collector cavity is considered as a radiatively participating medium. The finite volume method has been adopted to solve the governing equations and discrete ordinates method is used for radiative transfer. After validating the model used in this study, it is used to obtain the heat transfer characteristics of a flat-plate solar collector with real solar conditions of the city of Kerman, Iran, in summer at a wide range of air absorption coefficients. According to the results, by increasing the absorption coefficient of the air, the temperature of the absorber plate is reduced and the air temperature is increased, but the increase of air temperature is much higher than the reduction of absorber temperature. Hence, it is concluded that it is possible to use participating gases in the solar air heaters to enhance the performance of the collector.


Author(s):  
Ahmad M. Saleh ◽  
Donald W. Mueller ◽  
Hosni I. Abu-Mulaweh

Solar energy is a viable alternative to limited fossil fuel resources. One of the simplest and most direct applications of this energy is the conversion of solar radiation into thermal energy with a flat-plate solar collector which can be used in water-heating systems. This paper presents a mathematical model for simulating the transient processes which occur in liquid flat-plate solar collectors. A discrete nodal model that represents the flat-plate solar collector’s layers and the storage tank is employed. The model is based on solving a system of coupled differential equations which describe the energy conservation for the glass cover, air gap, absorber, fluid, insulation, and the storage tank. Inputs to the model include the time-varying liquid flow rate, incident solar radiation, and ambient air temperature, as well as the volume of liquid in the storage tank and initial temperature of the solar collector and tank. The system of differential equations is solved iteratively using an implicit, finite-difference formulation executed with MATLAB software. In order to verify the proposed method, an experiment was designed and conducted on different days with variable ambient conditions and flow rates. The comparison between the time-varying computed and measured fluid temperature at the collector outlet shows good agreement. The proposed method is extremely general and flexible accounting for variable ambient conditions and flow rates, as well as allowing for a geometrical and thermophysical description of all essential components of the solar collector system, including the storage tank. The validated and verified, general model is suitable to investigate the effectiveness of various components without the necessity of carrying out experimental work, and the flexible computational scheme is useful for transient simulations of energy systems.


Author(s):  
A. Alvárez ◽  
M. Baz ◽  
O. Cabeza ◽  
J.L. Ferrín ◽  
M.C. Muñiz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document