scholarly journals Effect of geometrical parameters on heat transfer and pressure drop characteristics of plate fin and tube heat exchangers

2005 ◽  
Vol 25 (14-15) ◽  
pp. 2421-2431 ◽  
Author(s):  
Aytunç Erek ◽  
Barış Özerdem ◽  
Levent Bilir ◽  
Zafer İlken
Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2069
Author(s):  
Eloy Hontoria ◽  
Alejandro López-Belchí ◽  
Nolberto Munier ◽  
Francisco Vera-García

This paper proposes a methodology aiming at determining the most influent working variables and geometrical parameters over the pressure drop and heat transfer during the condensation process of several refrigerant gases using heat exchangers with pipes mini channels technology. A multi-criteria decision making (MCDM) methodology was used; this MCDM includes a mathematical method called SIMUS (Sequential Interactive Modelling for Urban Systems) that was applied to the results of 2543 tests obtained by using a designed refrigeration rig in which five different refrigerants (R32, R134a, R290, R410A and R1234yf) and two different tube geometries were tested. This methodology allows us to reduce the computational cost compared to the use of neural networks or other model development systems. This research shows six variables out of 39 that better define simultaneously the minimum pressure drop, as well as the maximum heat transfer, saturation pressure fluid entering the condenser being the most important one. Another aim of this research was to highlight a new methodology based on operation research for their application to improve the heat transfer energy efficiency and reduce the CO2 footprint derived of the use of heat exchangers with minichannels.


Author(s):  
C-C Wang ◽  
Y-P Chang ◽  
K-Y Chi ◽  
Y-J Chang

Extensive experiments on the heat transfer and pressure drop characteristics of louvre finand-tube heat exchangers were carried out. In the present study, 14 samples of non-redirection louvre fin-and-tube heat exchangers with different geometrical parameters, including the number of tube row, fin pitch and tube size, were tested in a wind tunnel. Results are presented as plots of the Fanning friction factor f and the Colburn j factor against Reynolds number based on the tube collar diameter in the range of 300–8000.


Author(s):  
Morteza Khoshvaght Aliabadi ◽  
Faramarz Hormozi ◽  
Elham Hosseini Rad

Purpose – The main purpose of this paper is the generation of the heat transfer and pressure drop correlations by considering three working fluids, namely air, water, and ethylene glycol, for the wavy plate-fin heat exchangers (PFHEs). Design/methodology/approach – In order to present the general correlations, various models with different geometrical parameters should be tested. Because of the problems, such as difficult, long time, and costly fabrication of the wavy fins in experimental tests, computational fluid dynamics (CFD) calculations can be a useful method for the generation of the heat transfer and pressure drop correlations with eliminating the experimental problems. Hence, the effective design parameters of the wavy plate-fin, including fin pitch, fin height, wave length, fin thickness, wave amplitude, and fin length, and also their levels were recognized from the literature. The Taguchi method was applied to formulate the CFD simulation work. Findings – The simulation results were compared and validated with an available experimental data. The mean deviations of the Colburn factor, j, and Fanning friction factor, f, values between the simulation results and the experimental data were 3.74 and 9.07 percent, respectively. The presented air correlations and experimental data were in a good agreement, so that approximately 95 percent of the experimental data were correlated within ±12 percent. The j factor values varied for the different working fluids, while the f factor values did not sensibly change. Practical implications – The presented correlations can be used to estimate the thermal-hydraulic characteristics and to design of the compact PFHE with the wavy channels. Originality/value – This manuscript presents the new correlations for the compact PFHEs with the way channels by considering all the geometrical parameters and the working fluids with the different Prandtl numbers, 0.7, 7, and 150.


2009 ◽  
Vol 131 (6) ◽  
Author(s):  
Young-Gil Park ◽  
Anthony M. Jacobi

The air-side thermal-hydraulic performance of flat-tube aluminum heat exchangers is studied experimentally for conditions typical to air-conditioning applications, for heat exchangers constructed with serpentine louvered, wavy, and plain fins. Using a closed-loop calorimetric wind tunnel, heat transfer and pressure drop are measured at air face velocities from 0.5 m/s to 2.8 m/s for dry- and wet-surface conditions. Parametric effects related to geometry and operating conditions on heat transfer and friction performance of the heat exchangers are explored. Significant differences in the effect of geometrical parameters are found for dry and wet conditions. For the louver-fin geometry, using a combined database from the present and the previous studies, empirical curve-fits for the Colburn j- and f-factors are developed in terms of a wet-surface multiplier. The wet-surface multiplier correlations fit the present database with rms relative residuals of 21.1% and 24.4% for j and f multipliers, respectively. Alternatively, stand-alone Colburn j and f correlations give rms relative residuals of 22.7% and 29.1%, respectively.


2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2013 ◽  
Vol 655-657 ◽  
pp. 461-464 ◽  
Author(s):  
Su Fang Song

The three-dimensional model of heat exchangers with continuous helical baffles was built. The fluid flow dynamics and heat transfer of shell side in the helical baffled heat exchanger were simulated and calculated. The velocity, pressure and temperature distributions were achieved. The simulation shows that with the same baffle pitch, shell-side heat transfer coefficient increased by 25% and the pressure drop decreases by 18% in helical baffled heat exchanger compared with segmental helical baffles. With the analyzing of the flow and heat transfer in heat exchanger in 5 different inclination angles from 11°to 21°, it can be found that both shell side heat transfer coefficient and pressure drop will reduce respectively by 86% and 52% with the increases 11°to 21°of the inclination angles. Numerical simulation provided reliable theoretical reference for further engineering research of heat exchanger with helical baffles.


2013 ◽  
Vol 465-466 ◽  
pp. 500-504 ◽  
Author(s):  
Shahrin Hisham Amirnordin ◽  
Hissein Didane Djamal ◽  
Mohd Norani Mansor ◽  
Amir Khalid ◽  
Md Seri Suzairin ◽  
...  

This paper presents the effect of the changes in fin geometry on pressure drop and heat transfer characteristics of louvered fin heat exchanger numerically. Three dimensional simulation using ANSYS Fluent have been conducted for six different configurations at Reynolds number ranging from 200 to 1000 based on louver pitch. The performance of this system has been evaluated by calculating pressure drop and heat transfer coefficient. The result shows that, the fin pitch and the louver pitch have a very considerable effect on pressure drop as well as heat transfer rate. It is observed that increasing the fin pitch will relatively result in an increase in heat transfer rate but at the same time, the pressure drop will decrease. On the other hand, low pressure drop and low heat transfer rate will be obtained when the louver pitch is increased. Final result shows a good agreement between experimental and numerical results of the louvered fin which is about 12%. This indicates the capability of louvered fin in enhancing the performance of heat exchangers.


Author(s):  
Josua P. Meyer ◽  
Leon Liebenberg ◽  
Jonathan A. Olivier

Heat exchangers are usually designed in such a way that they do not operate in the transition region. This is usually due to a lack of information in this region. However, due to design constraints, energy efficiency requirements or change of operating conditions, heat exchangers are often forced to operate in this region. It is also well known that entrance disturbances influence where transition occurs. The purpose of this paper is to present experimental heat transfer and pressure drop data in the transition region for fully developed and developing flows inside smooth tubes using water as the working fluid. The use of different inlet disturbances were used to investigate its effect on transition. A tube-in-tube heat exchanger was used to perform the experiments, which ranged in Reynolds numbers from 1 000 to 20 000, with Prandtl numbers being between 4 and 6 while Grashof numbers were in the order of 105. Results showed that the type of inlet disturbance could delay transition to a Reynolds number as high as 7 000, while other inlets expedited it, confirming results of others. For heat transfer, though, it was found that transition was independent of the inlet disturbance and all commenced at the same Reynolds number, 2 000–3 000, which was attributed to secondary flow effects.


Sign in / Sign up

Export Citation Format

Share Document