Effect of polymeric support material on biofilm development, bacterial population, and wastewater treatment performance in anaerobic fixed-film systems

Chemosphere ◽  
2021 ◽  
Vol 264 ◽  
pp. 128477
Author(s):  
Yuren Zhou ◽  
Patrick D. Kiely ◽  
Richard Kibbee ◽  
Banu Ormeci
1989 ◽  
Vol 21 (4-5) ◽  
pp. 157-165 ◽  
Author(s):  
F. Ehlinger ◽  
J. M. Audic ◽  
G. M. Faup

The characterization of the biofilm of an anaerobic fluidized-bed reactor was completed under standard conditions. The distribution of the fixed protein concentration depended on the level in the reactor. The protein concentration reached 1520 µg.g−1 of support at the top of the reactor and only 1200 µg.g−1 at the bottom after 504 hours of operation but the specific activity of the biofilm was 33×10−4 µM acetate.h−1.mg−1 proteins at the bottom and only 26×10−4 µM.h−1.mg−1 at the top. The efficiency of a fluidized bed reactor and the composition of the biofilm changed with an increase of the pH from 7 to 8.5 during the seeding of the support material. Future development of the biofilm and the specific activity of the support were affected.


1990 ◽  
Vol 22 (1-2) ◽  
pp. 101-111 ◽  
Author(s):  
J. Wanner ◽  
M. Sýkora ◽  
M. Kos ◽  
J. Miklenda ◽  
P. Grau

The situation in the treatment of wastewaters from small sources in Czechoslovakia has been discussed and two types of manufactured rotating biological contactors have been described. The evaluation of RBCs' operation showed the main disadvantages of the contactors with conventional discs, viz. the low 0C and low mixing effect. In a newly designed RBC, the discs or packets of discs were replaced by a cage packed with a random medium. The cage was equipped with tubular aeration and mixing elements. The long-term tests with a pilot-plant and a full-scale unit using synthetic as well as municipal wastewaters proved the ability of the packed-cage RBC to achieve a low effluent BOD with such organic loadings when the effluent from the conventional RBCs already deteriorated. Besides the BOD removal the 0C of the packed-cage RBCs was tested to verify the possibility of the combined cultivation of suspended and fixed-film biomass. On the basis of results presented here, a new package wastewater treatment plant for about 500 PE will be designed.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


Sign in / Sign up

Export Citation Format

Share Document