scholarly journals Determination of synthetic phenolic antioxidants and relative metabolites in sewage treatment plant and recipient river by high performance liquid chromatography–electrospray tandem mass spectrometry

2015 ◽  
Vol 1381 ◽  
pp. 13-21 ◽  
Author(s):  
Runzeng Liu ◽  
Ting Ruan ◽  
Shanjun Song ◽  
Yongfeng Lin ◽  
Guibin Jiang
Molecules ◽  
2019 ◽  
Vol 24 (3) ◽  
pp. 633 ◽  
Author(s):  
Mohammad Semreen ◽  
Abdallah Shanableh ◽  
Lucy Semerjian ◽  
Hasan Alniss ◽  
Mouath Mousa ◽  
...  

The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater received and treated by Sharjah sewage treatment plant (STP). The extraction efficiency of different SPE cartridges was tested and the simultaneous extraction of pharmaceuticals was successfully accomplished using hydrophilic-lipophilic-balanced reversed phase Waters® Oasis HLB cartridge (200 mg/ 6 mL) at pH 3. The analytes were separated on an Aquity BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using gradient elution and mass spectrometric analysis were performed in multiple reactions monitoring (MRM) selecting two precursor ions to produce ion transition for each pharmaceutical using positive electrospray ionization (+ESI) mode. The correlation coefficient values in the linear calibration plot for each target compound exceeded 0.99 and the recovery percentages of the investigated pharmaceuticals were more than 84%. Limit of detection (LOD) varied between 0.1–1.5 ng/L and limit of quantification (LOQ) was 0.3–5 ng/L for all analytes. The precision of the method was calculated as the relative standard deviation (RSD%) of replicate measurements and was found to be in the ranges of 2.2% to 7.7% and 2.2% to 8.6% for inter and intra-day analysis, respectively. All of the obtained validation parameters satisfied the requirements and guidelines of analytical method validation.


Author(s):  
Mohammad H. Semreen ◽  
Abdallah Shanableh ◽  
Lucy Semerjian ◽  
Hasan Alniss ◽  
Muath Mousa ◽  
...  

The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater received and treated by Sharjah sewage treatment plant (STP). The extraction efficiency of different SPE cartridges was tested and the simultaneous extraction of pharmaceuticals was successfully accomplished using hydrophilic-lipophilic-balanced reversed phase Waters® Oasis HLB cartridge (200 mg/ 6 mL) at pH 3. The analytes were separated on an Aquity BEH C18 column (1.7 µm, 2.1 mm x 150 mm) using gradient elution and the mass spectrometric analysis were performed in multiple reactions monitoring (MRM) selecting two precursor ions to produce ion transition for each pharmaceutical using positive electrospray ionization (+ESI) mode. The correlation coefficient values in the linear calibration plot for each target compound exceeded 0.99 and the recovery percentages of the investigated pharmaceuticals were more than 84%. Limit of detection (LOD) varied between 0.1-1.5 ng/L and limit of quantification (LOQ) was 0.3-5 ng/L for all analytes. The precision of the method was calculated as the relative standard deviation (RSD%) of replicate measurements and was found to be in the ranges of 2.2% to 7.7% and 2.2% to 8.6% for inter and intra-day analysis, respectively. All of the obtained validation parameters satisfied the requirements and guidelines of analytical method validation.


Sign in / Sign up

Export Citation Format

Share Document