Direct tensile behavior of shape-memory-alloy fiber-reinforced cement composites

2016 ◽  
Vol 102 ◽  
pp. 462-470 ◽  
Author(s):  
Min Kyoung Kim ◽  
Dong Joo Kim ◽  
Young-Soo Chung ◽  
Eunsoo Choi
2013 ◽  
Vol 2013 ◽  
pp. 1-11 ◽  
Author(s):  
Won-Chang Choi ◽  
Hyun-Do Yun

High-performance fiber-reinforced cement composites (HPFRCCs) are characterized by strain-hardening and multiple cracking during the inelastic deformation process, but they also develop high shrinkage strain. This study investigates the effects of replacing Portland cement with calcium sulfoaluminate-based expansive admixtures (CSA EXAs) to compensate for the shrinkage and associated mechanical behavior of HPFRCCs. Two types of CSA EXA (CSA-K and CSA-J), each with a different chemical composition, are used in this study. Various replacement ratios (0%, 8%, 10%, 12%, and 14% by weight of cement) of CSA EXA are considered for the design of HPFRCC mixtures reinforced with 1.5% polyethylene (PE) fibers by volume. Mechanical properties, such as shrinkage compensation, compressive strength, flexural strength, and direct tensile strength, of the HPFRCC mixtures are examined. Also, crack width and development are investigated to determine the effects of the EXAs on the performance of the HPFRCC mixtures, and a performance index is used to quantify the performance of mixture. The results indicate that replacements of 10% CSA-K (Type 1) and 8% CSA-J (Type 2) considerably enhance the mechanical properties and reduce shrinkage of HPFRCCs.


Carbon Trends ◽  
2021 ◽  
Vol 3 ◽  
pp. 100030
Author(s):  
Jin Hee Kim ◽  
Jong Hun Han ◽  
Seungki Hong ◽  
Doo-Won Kim ◽  
Sang Hee Park ◽  
...  

2021 ◽  
Vol 11 (3) ◽  
pp. 1112
Author(s):  
Nikita Belyakov ◽  
Olga Smirnova ◽  
Aleksandr Alekseev ◽  
Hongbo Tan

The problem of damage accumulation in fiber-reinforced concrete to structures supporting underground workings and tunnel linings against dynamic loading is insufficiently studied. The mechanical properties were determined and the mechanism of destruction of fiber-reinforced concrete with different reinforcement parameters is described. The parameters of the Concrete Damaged Plasticity model for fiber-reinforced concrete at different reinforcement properties are based on the results of lab experiments. Numerical simulation of the composite concrete was performed in the Simulia Abaqus software package (Dassault Systemes, Vélizy-Villacoublay, France). Modeling of tunnel lining based on fiber-reinforced concrete was performed under seismic loading.


2005 ◽  
Vol 35 (2) ◽  
pp. 296-300 ◽  
Author(s):  
Yiping Ma ◽  
Beirong Zhu ◽  
Muhua Tan

Sign in / Sign up

Export Citation Format

Share Document