Granular activated carbon (GAC) adsorption of two algal odorants, dimethyl trisulfide and β-cyclocitral

Desalination ◽  
2011 ◽  
Vol 266 (1-3) ◽  
pp. 231-237 ◽  
Author(s):  
Ke-jia Zhang ◽  
Nai-yun Gao ◽  
Yang Deng ◽  
Ming-hao Shui ◽  
Yu-lin Tang
2003 ◽  
Vol 47 (1) ◽  
pp. 113-120 ◽  
Author(s):  
D.S. Chaudhary ◽  
S. Vigneswaran ◽  
V. Jegatheesan ◽  
H.H. Ngo ◽  
H. Moon ◽  
...  

Wastewater treatment has always been a major concern in the developed countries. Over the last few decades, activated carbon adsorption has gained importance as an alternative tertiary wastewater treatment and purification process. In this study, granular activated carbon (GAC) adsorption was evaluated in terms of total organic carbon (TOC) removal from low strength synthetic wastewater. This paper provides details on adsorption experiments conducted on synthetic wastewater to develop suitable adsorption isotherms. Although the inorganics used in the synthetic wastewater solution had an overall unfavourable effect on adsorption of organics, the GAC adsorption system was found to be effective in removing TOC from the wastewater. This study showed that equation of state (EOS) theory was able to fit the adsorption isotherm results more precisely than the most commonly used Freundlich isotherm. Biodegradation of the organics with time was the most crucial and important aspect of the system and it was taken into account in determining the isotherm parameters. Initial organic concentration of the wastewater was the determining factor of the model parameters, and hence the isotherm parameters were determined covering a wide range of initial organic concentrations of the wastewater. As such, the isotherm parameters derived using the EOS theory could predict the batch adsorption and fixed bed adsorption results of the multi-component system successfully. The isotherm parameters showed a significant effect on the determination of the mass transfer coefficients in batch and fixed bed systems.


1997 ◽  
Vol 35 (7) ◽  
pp. 197-204 ◽  
Author(s):  
Sarah L. VanderLoop ◽  
Makram T. Suidan ◽  
Sandra R. Berchtold ◽  
Moustafa A. Moteleb ◽  
Stephen W. Maloney

Munitions wastewaters are commonly treated by granular activated carbon (GAC) adsorption followed by incineration of the spent carbon. The design of effective GAC unit processes hinges on the knowledge of GAC adsorption capacity for the compounds of interest as well as the types of chemical interactions to expect. GAC can often catalyze polymerization or chemical degradation of the adsorbate in the presence of molecular oxygen. Some adsorbates, though less common, may be subject to catalytic activity even when no molecular oxygen is present. The products of these interactions may enhance or interfere with effective waste treatment. This study individually evaluated the adsorption properties of a variety of energetics compounds. A number of surface catalyzed polymerization and degradation reactions were noted.


RSC Advances ◽  
2016 ◽  
Vol 6 (65) ◽  
pp. 60815-60825 ◽  
Author(s):  
Tianlong Zheng ◽  
Qunhui Wang ◽  
Zhining Shi ◽  
Zhihui Zhang ◽  
Yuhui Ma

In this study, an integrated granular activated carbon (GAC) adsorption/microwave (MW) irradiation process was used for the treatment of ester-containing wastewater from a lithium-ion battery (LIB) factory.


2010 ◽  
Vol 10 (1) ◽  
pp. 15-22 ◽  
Author(s):  
X. Liu ◽  
C. S. B. Fitzpatrick

This study proposed a new method using freely available sunlight and granular activated carbon (GAC) adsorption for enhanced removal of humic substances (HS). Experiments were carried out under natural sunlight conditions in winter and summer. A parabolic solar collector (PC) was applied to concentrate solar energy. HS were characterized by UV254 absorbance, dissolved organic carbon (DOC) concentration and molecular weight (MW). As a result of solar irradiation, decreases of DOC up to 14% in winter and 58% in summer were observed. A comparison of adsorption isotherms and chromatograms of the irradiated and non-irradiated HS confirmed that smaller molecules formed during solar irradiation were preferentially adsorbed by GAC. A dramatic MW change upon solar irradiation was observed in HS irradiation in PC in summer experiment and almost no UV254 detected components were remaining in solution after adsorption (GAC dose 400 mg/L), as measured with high performance size exclusion chromatography (HPSEC). The combined solar irradiation-GAC adsorption method proved to be effective in enhancing HS removal by GAC with no additional energy and chemicals consumption.


2004 ◽  
Vol 49 (5-6) ◽  
pp. 129-136 ◽  
Author(s):  
S.-Y. Oh ◽  
D.K. Cha ◽  
P.C. Chiu ◽  
B.J. Kim

Pink water, explosive-laden wastewater produced in army ammunition plants is often treated using expensive and non-destructive granular activated carbon (GAC) adsorption. This paper compares GAC adsorption and two alternative treatment technologies, anaerobic GAC fluidized bed reactor and zero-valent iron-Fenton process. The bench-scale demonstration of the zero-valent iron-Fenton process with real pink water is reported. The features of three technologies are compared and their advantages and drawbacks are discussed.


2021 ◽  
Author(s):  
Kiran K. Shah

The treatment of pharmaceutical wastewater was performed at the lab scale using UV/H₂O₂, process granular activated carbon (GAC) adsorption and their combination to investigate the total organic carbon (TOC) removal efficiency for different inlet TOC loadings and treatment times. Experimental study revealed that GAC adsorption alone had 81% efficiency in TOC removal in 10 min breakthrough time for flow rate of 0.6 L/min with granular activated carbon dosage of 333.33 mgActivated Carbon/L whereas UV/H₂O₂ process alone showed 26 and 29% TOC reduction at with 21.7 g/LH₂O₂ concentration with 254 and 185 nm wavelength lamps a 6 h hydraulic retention time, respectively, with average feed concentration (TOC) of 1,7555.75 mgC/L and COD of 5,214.6 mg/L at 25 ± 5°C. Experimental results showed that the optimum H₂O₂ dosage for the UV/H₂O₂ process was 1:2 stoichiometric COD: H₂O₂ molar ratio to achieve up to 26 and 29% TOC reduction efficiency than that at pH 12.01 which resulted 15-20% TOC reduction efficiency. The Bohart-Adams rate constants (K) and maximum adsorption capacity of carbon (N) from column breakthrough studies for synthetic pharmaceutical wastewater at 81% were found to be 7.10 x 10⁻³ L/(min.mgC) and 1.06 x 10³ mgC/L, respectively. In combined processes, it was found that GAC adsorption followed by desorption of contaminants from GAC by steam and UV₂₅₄/H₂O₂ treatment of the condensed steam let to 81% of TOC removal from the wastewater. Out of 358.73 mgC/L of TOC desorbed 88.1% of TOC was degraded in the UV₂₅₄/H₂O₂ treatment was degradation. Total operating cost of GAC adsortpion followed by desorption of contaminants from GAC by steam and UV₂₅₄/H₂O₂ treatment of condensed steam were found to be $11/L. While the pre-treated wastewater by UV₂₅₄H₂O₂ treatment followed by GAC adsorption, along the desorption of contaminants from GAC using steam and UV₂₅₄/H₂O₂ treatment of the condensed steam, let to an overall 81% TOC removal and 75.1% of TOC degradation using UV₂₅₄/H₂O₂ process. The cost of this combined treatment was found to be $6/L of wastewater treated which led to an economical saving of $5/L with respect to the combined TOC removal and degradation efficiency achieved. The savings predictions were achieved due to the less carbon dosage requirement and ability of UV/H₂O₂ process to degrade the TOC present in the wastewater. Based on single and combined treatments, the minimum total cost and time for 81% TOC removal were determined for the combination of UV₂₅₄/H₂O₂ treatment followed by GAC adsorption, along with desorption of contaminants from GAC using steam and UV₂₅₄/H₂O₂ treatment of the condensed steam. The overall minimum cost and minimum time were found to be $6/L of wastewater treated and 114.5 h, respectively. The treatment parameters and conditions for treating 30 L of the synthetic pharmaceutical wastewater were at an average feed concentration of TOC = 1,755.75 mgC/L and COD = 5,214.6 mg/L leading to TOC = 333.5 mgC/L of the effluent concentration which was near to the industrial effluent disposal level in Canada.


2018 ◽  
Vol 228 ◽  
pp. 189-196 ◽  
Author(s):  
Ehsan Mohammad-pajooh ◽  
Ariel E. Turcios ◽  
Graham Cuff ◽  
Dirk Weichgrebe ◽  
Karl-Heinz Rosenwinkel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document