Empirical validation of gradient field models for an accurate ADC measured on clinical 3T MR systems in body oncologic applications

2021 ◽  
Vol 86 ◽  
pp. 113-120
Author(s):  
Yuxi Pang ◽  
Dariya I. Malyarenko ◽  
Ghoncheh Amouzandeh ◽  
Enzo Barberi ◽  
Michael Cole ◽  
...  
2013 ◽  
Vol 74 (S 01) ◽  
Author(s):  
Douglas Stofko ◽  
Gregory Moore ◽  
Thomas Nickles ◽  
Amir Dehdashti

2020 ◽  
Vol 64 (1-4) ◽  
pp. 19-29
Author(s):  
Shuting Ren ◽  
Yong Li ◽  
Bei Yan ◽  
Jinhua Hu ◽  
Ilham Mukriz Zainal Abidin ◽  
...  

Structures of nonmagnetic materials are broadly used in engineering fields such as aerospace, energy, etc. Due to corrosive and hostile environments, they are vulnerable to the Subsurface Pitting Corrosion (SPC) leading to structural failure. Therefore, it is imperative to conduct periodical inspection and comprehensive evaluation of SPC using reliable nondestructive evaluation techniques. Extended from the conventional Pulsed eddy current method (PEC), Gradient-field Pulsed Eddy Current technique (GPEC) has been proposed and found to be advantageous over PEC in terms of enhanced inspection sensitivity and accuracy in evaluation and imaging of subsurface defects in nonmagnetic conductors. In this paper two GPEC probes for uniform field excitation are intensively analyzed and compared. Their capabilities in SPC evaluation and imaging are explored through simulations and experiments. The optimal position for deployment of the magnetic field sensor is determined by scrutinizing the field uniformity and inspection sensitivity to SPC based on finite element simulations. After the optimal probe structure is chosen, quantitative evaluation and imaging of SPC are investigated. Signal/image processing algorithms for SPC evaluation are proposed. Through simulations and experiments, it has been found that the T-shaped probe together with the proposed processing algorithms is advantageous and preferable for profile recognition and depth evaluation of SPC.


2017 ◽  
Author(s):  
Eugenia Isabel Gorlin ◽  
Michael W. Otto

To live well in the present, we take direction from the past. Yet, individuals may engage in a variety of behaviors that distort their past and current circumstances, reducing the likelihood of adaptive problem solving and decision making. In this article, we attend to self-deception as one such class of behaviors. Drawing upon research showing both the maladaptive consequences and self-perpetuating nature of self-deception, we propose that self-deception is an understudied risk and maintaining factor for psychopathology, and we introduce a “cognitive-integrity”-based approach that may hold promise for increasing the reach and effectiveness of our existing therapeutic interventions. Pending empirical validation of this theoretically-informed approach, we posit that patients may become more informed and autonomous agents in their own therapeutic growth by becoming more honest with themselves.


2002 ◽  
Vol 97 ◽  
pp. 563-568 ◽  
Author(s):  
Paul Jursinic ◽  
Robert Prost ◽  
Christopher Schultz

Object. The authors report on a new head coil into which the Leksell aluminum localization frame can be easily and securely mounted. Mechanically, the head coil interferes little with the patient. Methods. The head coil, which is for magnetic resonance (MR) imaging, is a 12-element quadrature transmitand-receive high-pass birdcage coil with a nominal operation frequency (63.86 MHz). The coil was built into a plastic housing. This new head coil minimizes patient motion and provides a 20% increase in signal/noise ratios compared with standard head coils. An MR image test phantom was mounted in the coil and this allowed quantification of image distortion due to inhomogeneities in the main magnetic field, nonlinearity in the gradient field, and paramagnetism of the aluminum headframe. There were no significant differences in geometric distortion between the new head coil and the standard coil. Conclusions. The new head coil has advantages for reducing patient movement artifacts and has a better signal/noise ratio with no reduction in geometric accuracy.


Sign in / Sign up

Export Citation Format

Share Document