Exergy–economic evaluation of heat recovery device in mechanical ventilation system

2015 ◽  
Vol 86 ◽  
pp. 296-304 ◽  
Author(s):  
Tomasz M. Mróz ◽  
Anna Dutka
2016 ◽  
Vol 133 ◽  
pp. 111-121 ◽  
Author(s):  
F. Fucci ◽  
C. Perone ◽  
G. La Fianza ◽  
L. Brunetti ◽  
F. Giametta ◽  
...  

Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 105
Author(s):  
Aldona Skotnicka-Siepsiak

In the present study, the real-world performance of a ground-to-air heat exchanger (GAHE) was analyzed in the Polish climate which is characterized by warm summers and cold winters. The heat exchanger’s performance was monitored over a period of three years (2017 to 2019), and real-world conditions were compared with a Typical Meteorological Year (TMY). The aim of the study was to assess the exchanger’s energy-efficiency potential in various ventilation scenarios in a single-family home under variable real-world conditions, rather than to simply determine its heating and cooling capacity. The analyzed single-family home was a modern, single-story building with a usable floor area of 115 m2. The building’s thermal insulation and airtightness met stringent energy-efficiency standards. Energy consumption in a building equipped with a natural ventilation system was compared with three other scenarios: ventilation coupled with a GAHE, mechanical ventilation with heat recovery and a high-efficiency heat exchanger (HE), and mechanical ventilation with heat recovery coupled with a GAHE. Sensible heating and cooling loads were calculated based on standard ISO 13790:2008, and latent heating and cooling loads were also included in the energy balance. During the year, the GAHE generated around 257.6 W of heating energy per hour and 124.7 W of cooling energy per hour. Presented results can be used to select the optimal HVAC system scenarios for engineering projects as well as private investors.


2015 ◽  
Vol 72 ◽  
pp. 27-33 ◽  
Author(s):  
Edite Kamendere ◽  
Gatis Zogla ◽  
Agris Kamenders ◽  
Janis Ikaunieks ◽  
Claudio Rochas

Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3008
Author(s):  
Agnieszka W. Lach ◽  
André V. Gaathaug

This paper presents a series of experiments on the effectiveness of existing mechanical ventilation systems during accidental hydrogen releases in confined spaces, such as underground garages. The purpose was to find the mass flow rate limit, hence the TPRD diameter limit, that will not require a change in the ventilation system. The experiments were performed in a 40 ft ISO container in Norway, and hydrogen gas was used in all experiments. The forced ventilation system was installed with a standard 315 mm diameter outlet. The ventilation parameters during the investigation were British Standard with 10 ACH and British Standard with 6 ACH. The hydrogen releases were obtained through 0.5 mm and 1 mm nozzles from different hydrogen reservoir pressures. Both types of mass flow, constant and blowdown, were included in the experimental matrix. The analysis of the hydrogen concentration of the created hydrogen cloud in the container shows the influence of the forced ventilation on hydrogen releases, together with TPRD diameter and reservoir pressure. The generated experimental data will be used to validate a CFD model in the next step.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7537
Author(s):  
Piotr Lis ◽  
Anna Lis

The majority of education buildings in Poland are equipped with natural (gravity) ventilation, where the air inflow depends on the level of window airtightness. A complete statistical urban population of 50 school buildings in Czestochowa have been examined. The main issue to be clarified is the answer to the following questions: Is it theoretically possible to supply enough air to meet the ventilation requirements with gravity ventilation? What is the airtightness of the windows at which it will be possible? The average technical conditions of windows in the analysed buildings were bad. However, only in the case in which high external air leakage coefficient a = 7.0 m3/(h m daPa2/3) (q100KL = 32.4912 m3/(h m) is the amount of air passing through the leaks similar to the quantitative ventilation requirements for classrooms. The quantity of air flowing from the outside through modernized windows that meet the technical requirements (a = 0.6 to 1.0 m3/(m h daPa2/3)) covers on average only about 12% and about 21% of the ventilation needs. Without installing additional vents in the rooms, or better yet, installing mechanical ventilation with heat recovery, meeting the ventilation norm requirements will be impossible.