Numerical study of heat transfer on using lobed cross sections in helical coil heat exchangers: Effect of physical and geometrical parameters

2018 ◽  
Vol 176 ◽  
pp. 236-245 ◽  
Author(s):  
Mohamad Omidi ◽  
Mousa Farhadi ◽  
A. Ali Rabienataj Darzi
2016 ◽  
Vol 37 (4) ◽  
pp. 137-159 ◽  
Author(s):  
Rafał Andrzejczyk ◽  
Tomasz Muszyński

Abstract The shell and coil heat exchangers are commonly used in heating, ventilation, nuclear industry, process plant, heat recovery and air conditioning systems. This type of recuperators benefits from simple construction, the low value of pressure drops and high heat transfer. In helical coil, centrifugal force is acting on the moving fluid due to the curvature of the tube results in the development. It has been long recognized that the heat transfer in the helical tube is much better than in the straight ones because of the occurrence of secondary flow in planes normal to the main flow inside the helical structure. Helical tubes show good performance in heat transfer enhancement, while the uniform curvature of spiral structure is inconvenient in pipe installation in heat exchangers. Authors have presented their own construction of shell and tube heat exchanger with intensified heat transfer. The purpose of this article is to assess the influence of the surface modification over the performance coefficient and effectiveness. The experiments have been performed for the steady-state heat transfer. Experimental data points were gathered for both laminar and turbulent flow, both for co current- and countercurrent flow arrangement. To find optimal heat transfer intensification on the shell-side authors applied the number of transfer units analysis.


Author(s):  
Anthony Edward Morris ◽  
C. S. Wei ◽  
Runar Unnthorsson ◽  
Robert Dell

Since 2006, The Center for Innovation and Applied Technology (CIAT) at Cooper Union for the Advancement of Science and Art has been developing a system to use thermal pollution to heat the growth medium of green roofs. CIAT is researching various apparatus and techniques, including shell-and-tube and shell-and-coil heat exchangers, to improve its heated ground agricultural projects. There are limited recorded observations on shell-and-coil heat exchangers; therefore a laboratory work station was created of interchangeable components to test the efficiency of a variety of coil designs. This paper discusses the data collected on temperature, pressure, and flow rates for a straight tube and two different helical coils. The analysis of this data indicates the superiority of a helical coil design when compared to a straight tube design with respect to both rating and heat transfer rate. The same data analysis has lead to preliminary observations on how the contour properties of a helical coil influence the heat transfer rate through a coil. The authors intend to further this helical coil research to develop a useful mathematical model for determining efficient designs for shell-and-coil heat exchangers.


Author(s):  
Rakesh Kumar

Abstract: Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide the excellent thermal performance in helical coil heat exchangers. Research studies on heat transfer enhancement have gained serious momentum during recent years and have been proposed many techniques by different research groups [1]. A fluid with higher thermal conductivity has been developed to increase the efficiency of heat exchangers. The dispersion of 1-100nm sized solid nanoparticles in the traditional heat transfer fluids, termed as nanofluids, exhibit substantial higher convective heat transfer than that of traditional heat transfer fluids. Nanofluid is a heat transfer fluid which is the combination of nanoparticles and base fluid that can improve the performance of heat exchanger systems. In this present paper the efforts are made to understand that how to compare the heat transfer rate in Copper helically coiled tube and squared coiled tube heat exchanger using Zinc Oxide and Titanium Dioxide Nano fluid by studying research papers of various authors. Keywords: Helical Coil, Nano-fluid, Heat Exchanger, CFD, Pressure Drop, Temperature Distribution.


Author(s):  
Ehsan M. Languri ◽  
Aly H. Shaaban ◽  
Minsuk Kong ◽  
Jorge L. Alvarado

Heat transfer analysis of microencapsulated phase change material (MCPM) slurry flowing through a helical coil heat exchanger was carried out numerically. MPCM slurry at different mass fractions with known thermal and physical properties was chosen as heat transfer fluid (HTF). MPCM slurries can carry significantly higher thermal load when the PCM undergoes phase change within a specified temperature range. However, little is known as to how MPCM behave in helical coil heat exchangers. Helical coil heat exchangers are being used widely in many industrial applications including air conditioning systems due to their compactness and high thermal effectiveness. Enhancing the heat transfer rate of coil heat exchanger by using MPCM slurry without altering the existing parameters of coil heat exchangers such as shell diameter should lead to energy savings due to reductions in HTF pumping energy demands at identical heat loads. The ultimate goal of this study is to show a significant enhancement in heat transfer when MPCM slurry is pumped through helical coil heat exchangers. Unlike traditional HTF used in helical coil heat exchangers, the proposed MPCM slurry could alter the flow structure and the internal convection by inducing and enhancing the formation of secondary flows, as a result of phase change in the microencapsulated phase change material. Specifically, a three dimensional numerical study was undertaken to understand the effects of the helical coil heat exchanger geometry and the HTF flow characteristics on heat transfer enhancement. Baseline numerical simulations were conducted using water as HTF in order to compare with MPCM slurry numerical results. The numerical model was solved based on the finite volume method. The temperature-dependent properties of MPCM slurry and boundary conditions were considered. The promising results of this numerical study demonstrate the importance of formulated HTF and the geometry of the heat exchanger on the heat transfer enhancement and energy savings.


2015 ◽  
Vol 787 ◽  
pp. 172-176
Author(s):  
R. Maradona ◽  
S. Rajkumar

The applications of heat exchangers are vast and the enhancement of heat transfer and compact size are the key factors for designing the heat exchangers in order to achieve energy savings. In the field of tubular heat exchangers one of the possible ways for reducing the space occupied by the exchanger is by bending tube axis in helical shape. This option is particularly suitable when construction simplicity is needed and the geometry of the place in which the exchanger has to be housed is the cylindrical one. In this paper, an attempt is made to enhance the heat transfer rate without application of any external power. This is achieved by providing the helical tube in tubes. The parameters influencing the nature of flow in a helical coil heat exchanger are the tube geometry namely pitch coil diameter, pitch and tube diameter. CFD analysis is carried out to study these geometry effects on heat transfer and hydraulic characteristics by varying Reynolds number (hot fluid). The CFD results of velocity and temperature distribution in the heat exchanger are used to estimate the Nusselt number and heat transfer coefficient. This helps to arrive at an optimum value of Reynolds number and Nusselt number for the corresponding tube-to-coil diameter ratios.


2011 ◽  
Vol 7 (6) ◽  
pp. 848-855 ◽  
Author(s):  
Zhen Yang ◽  
Zhenxing Zhao ◽  
Yinhe Liu ◽  
Xiangyu Wang ◽  
Yongqiang Chang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2069
Author(s):  
Eloy Hontoria ◽  
Alejandro López-Belchí ◽  
Nolberto Munier ◽  
Francisco Vera-García

This paper proposes a methodology aiming at determining the most influent working variables and geometrical parameters over the pressure drop and heat transfer during the condensation process of several refrigerant gases using heat exchangers with pipes mini channels technology. A multi-criteria decision making (MCDM) methodology was used; this MCDM includes a mathematical method called SIMUS (Sequential Interactive Modelling for Urban Systems) that was applied to the results of 2543 tests obtained by using a designed refrigeration rig in which five different refrigerants (R32, R134a, R290, R410A and R1234yf) and two different tube geometries were tested. This methodology allows us to reduce the computational cost compared to the use of neural networks or other model development systems. This research shows six variables out of 39 that better define simultaneously the minimum pressure drop, as well as the maximum heat transfer, saturation pressure fluid entering the condenser being the most important one. Another aim of this research was to highlight a new methodology based on operation research for their application to improve the heat transfer energy efficiency and reduce the CO2 footprint derived of the use of heat exchangers with minichannels.


Sign in / Sign up

Export Citation Format

Share Document