Morphological, physiological and behavioral responses of an intertidal snail, Acanthina monodon (Pallas), to projected ocean acidification and cooling water conditions in upwelling ecosystems

2021 ◽  
pp. 118481
Author(s):  
Cristian Duarte ◽  
Nicole Jahnsen-Guzmán ◽  
Pedro A. Quijón ◽  
Patricio H. Manríquez ◽  
Marco A. Lardies ◽  
...  
CORROSION ◽  
1989 ◽  
Vol 45 (5) ◽  
pp. 420-428 ◽  
Author(s):  
J. Schreifels ◽  
P. Labine ◽  
R. Gailey ◽  
S. Goewert ◽  
M. O'Brien ◽  
...  

CORROSION ◽  
1985 ◽  
Vol 41 (1) ◽  
pp. 39-45 ◽  
Author(s):  
Orin Hollander ◽  
Roger C. May

Abstract Although benzotriazole and tolyltriazole are well known as extremely effective inhibitors of copper corrosion, very little has been reported in the literature regarding their chemistry, particularly in near neutral, low conductivity aqueous media. The behavior of these inhibitors was studied under typical cooling water conditions. Relationships between chemical properties and inhibition behavior are discussed. A modified theory of the mechanism of inhibition is proposed.


2018 ◽  
Vol 41 ◽  
Author(s):  
Kevin Arceneaux

AbstractIntuitions guide decision-making, and looking to the evolutionary history of humans illuminates why some behavioral responses are more intuitive than others. Yet a place remains for cognitive processes to second-guess intuitive responses – that is, to be reflective – and individual differences abound in automatic, intuitive processing as well.


Author(s):  
W. C. Bigelow ◽  
F. B. Drogosz ◽  
S. Nitschke

High vacuum systems with oil diffusion pumps usually have a pressure switch to protect against Insufficient cooling water; however, If left unattended for long periods of time, failure of the mechanical fore pump can occur with equally serious results. The device shown schematically in Fig. 1 has been found to give effective protection against both these failures, yet it is inexpensive and relatively simple to build and operate.With this system, pressure in the fore pump line is measured by thermocouple vacuum gage TVG (CVC G.TC-004) whose output is monitored by meter relay MRy (Weston 1092 Sensitrol) which is set to close if the pressure rises above about 0.2 torr. This energizes control relay CRy (Potter & Brumfield KA5Y 120VAC SPDT) cutting off power to solenoid-operated fore line valve Vf (Cenco 94280-4 Norm. Closed) which closes to prevent further leakage of air into the diffusion pump


1981 ◽  
Vol 12 (1) ◽  
pp. 26-35 ◽  
Author(s):  
Donald L. McCanna ◽  
Giacinto DeLapa

This report reviews 27 cases of children exhibiting functional hearing loss. The study reveals that most students were in the upper elementary grades and were predominantly females. These subjects were functioning below their ability level in school and were usually in conflict with school, home, or peers. Tests used were selected on the basis of their helping to provide early identification. The subjects' oral and behavioral responses are presented, as well as ways of resolving the hearing problem. Some helpful counseling techniques are also presented.


2002 ◽  
Vol 16 (2) ◽  
pp. 71-81 ◽  
Author(s):  
Caroline M. Owen ◽  
John Patterson ◽  
Richard B. Silberstein

Summary Research was undertaken to determine whether olfactory stimulation can alter steady-state visual evoked potential (SSVEP) topography. Odor-air and air-only stimuli were used to determine whether the SSVEP would be altered when odor was present. Comparisons were also made of the topographic activation associated with air and odor stimulation, with the view toward determining whether the revealed topographic activity would differentiate levels of olfactory sensitivity by clearly identifying supra- and subthreshold odor responses. Using a continuous respiration olfactometer (CRO) to precisely deliver an odor or air stimulus synchronously with the natural respiration, air or odor (n-butanol) was randomly delivered into the inspiratory airstream during the simultaneous recording of SSVEPs and subjective behavioral responses. Subjects were placed in groups based on subjective odor detection response: “yes” and “no” detection groups. In comparison to air, SSVEP topography revealed cortical changes in response to odor stimulation for both response groups, with topographic changes evident for those unable to perceive the odor, showing the presence of a subconscious physiological odor detection response. Differences in regional SSVEP topography were shown for those who reported smelling the odor compared with those who remained unaware of the odor. These changes revealed olfactory modulation of SSVEP topography related to odor awareness and sensitivity and therefore odor concentration relative to thresholds.


Sign in / Sign up

Export Citation Format

Share Document