scholarly journals Wave propagation, breaking, and overtopping on a 2D reef: A comparative evaluation of numerical codes for tsunami modelling

2019 ◽  
Vol 73 ◽  
pp. 122-131 ◽  
Author(s):  
M. Kazolea ◽  
A. Filippini ◽  
M. Ricchiuto ◽  
S. Abadie ◽  
M. Martin Medina ◽  
...  
2021 ◽  
Vol 925 (1) ◽  
pp. 012035
Author(s):  
H Khoirunnisa ◽  
S Karima ◽  
G Gumbira ◽  
R A Rachman

Abstract On 14th January 2021, there was a devastating earthquake (Mw 6.2) hit Mamuju and Majene, West Sulawesi, Indonesia at 18.28 UTC. According to National Disaster Management Authority, this event causes 84 casualties and 279 houses were damaged. The Sulawesi Island is situated in a very complex tectonic region, there are several thrusts and faults along the area such as Majene Thrust, Palu-Karo Thrust, Matano Fault, and Tolo Thrust that can lead to tectonic activities. One of the largest earthquakes was a 7.9 Mw in 1997 generated from North Sulawesi Megathrust that caused a catastrophic tsunami. Moreover, there were 9 tsunami events in the Makassar Strait from the year 1800 to 1999. In this research, three different scenarios of the tsunami in Majene were applied to obtain the tsunami elevation. Makassar Strait could be potentially generated tsunami wave from submarine landslides due to its steep bathymetry that will impact the coastline at Sulawesi and Kalimantan, so it is necessary to model the tsunami propagation using submarine landslide as the tsunami generation. The volume of submarine landslide had been used in tsunami submarine landslide modelling as an input. Those are included the height, width and length of the submarine landslide volume. Furthermore, the domain bathymetry was obtained from National Bathymetry (BatNas) with spacing grid of 300 m × 300 m. The submarine landslide coordinate is also needed as a source of tsunami at 2.98°S and 118.94°E. The slide angle and slope angle are also inputted in this modelling with three experimental volumes, namely 1 km3, 0.8 km3, and 0.5 km3. This submarine landslide tsunami modelling used the Non-Hydrostatic WAVE Model (NHWAVE) method to obtain tsunami wave generation. The result from NHWAVE model will be used for initial elevation of tsunami wave propagation using the Fully Nonlinear Boussinesq wave model - Total Variation Diminishing (FUNWAVE - TVD) method. The highest initial tsunami elevation value at each observation point obtained from the NHWAVE model occurred at point 18 (the closest location to the earthquake source), which is around 0.4 –1.2 m. The FUNWAVE simulation result is the tsunami wave propagation for 180 minutes later. In the 180th minute, the tsunami wave was still propagating towards the north of Sulawesi Island to the east of Kalimantan Island.


Author(s):  
J. M. Galbraith ◽  
L. E. Murr ◽  
A. L. Stevens

Uniaxial compression tests and hydrostatic tests at pressures up to 27 kbars have been performed to determine operating slip systems in single crystal and polycrystal1ine beryllium. A recent study has been made of wave propagation in single crystal beryllium by shock loading to selectively activate various slip systems, and this has been followed by a study of wave propagation and spallation in textured, polycrystal1ine beryllium. An alteration in the X-ray diffraction pattern has been noted after shock loading, but this alteration has not yet been correlated with any structural change occurring during shock loading of polycrystal1ine beryllium.This study is being conducted in an effort to characterize the effects of shock loading on textured, polycrystal1ine beryllium. Samples were fabricated from a billet of Kawecki-Berylco hot pressed HP-10 beryllium.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Sign in / Sign up

Export Citation Format

Share Document