Fused CT – Improved image quality of coronary arteries on postmortem CT by summation of repeated scans

2020 ◽  
Vol 22 ◽  
pp. 200386 ◽  
Author(s):  
Tomoya Kobayashi ◽  
Hidehiko Fukuoka ◽  
Shogo Suzuki ◽  
Seiji Shiotani ◽  
Hajime Saitou ◽  
...  
Author(s):  
Heiner Nebelung ◽  
Thomas Brauer ◽  
Danilo Seppelt ◽  
Ralf-Thorsten Hoffmann ◽  
Ivan Platzek

Abstract Objectives The aim of the study was to evaluate the effect of bolus-tracking ROI positioning on coronary computed tomography angiography (CCTA) image quality. Methods In this retrospective monocentric study, all patients had undergone CCTA by step-and-shoot mode to rule out coronary artery disease within a cohort at intermediate risk. Two groups were formed, depending on ROI positioning (left atrium (LA) or ascending aorta (AA)). Each group contained 96 patients. To select pairs of patients, propensity score matching was used. Image quality with regard to coronary arteries as well as pulmonary arteries was evaluated using quantitative and qualitative scores. Results In terms of the coronary arteries, there was no significant difference between both groups using quantitative (SNR AA 14.92 vs. 15.46; p = 0.619 | SNR LM 19.80 vs. 20.30; p = 0.661 | SNR RCA 24.34 vs. 24.30; p = 0.767) or qualitative scores (4.25 vs. 4.29; p = 0.672), respectively. With regard to pulmonary arteries, we found significantly higher quantitative (SNR RPA 8.70 vs. 5.89; p < 0.001 | SNR LPA 9.06 vs. 6.25; p < 0.001) and qualitative scores (3.97 vs. 2.24; p < 0.001) for ROI positioning in the LA than for ROI positioning in the AA. Conclusions ROI positioning in the LA or the AA results in comparable image quality of CT coronary arteriography, while positioning in the LA leads to significantly higher image quality of the pulmonary arteries. These results support ROI positioning in the LA, which also facilitates triple-rule-out CT scanning. Key Points • ROI positioning in the left atrium or the ascending aorta leads to comparable image quality of the coronary arteries. • ROI positioning in the left atrium results in significantly higher image quality of the pulmonary arteries. • ROI positioning in the left atrium is feasible to perform triple-rule-out CTA.


2006 ◽  
Vol 17 (1) ◽  
pp. 97-102 ◽  
Author(s):  
Tuncay Hazirolan ◽  
Baris Turkbey ◽  
Musturay Karcaaltincaba ◽  
Deniz Akata ◽  
Levent Sahiner ◽  
...  

2017 ◽  
Vol 59 (2) ◽  
pp. 170-179
Author(s):  
Ji Won Lee ◽  
Chang Won Kim ◽  
Geewon Lee ◽  
Han Cheol Lee ◽  
Sang-Pil Kim ◽  
...  

Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries ( P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA ( P = 0.013). Conclusion Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.


Author(s):  
Andrea Steuwe ◽  
Judith Boeven ◽  
Lena Cordes ◽  
Stefano Draisci ◽  
Johannes Boos ◽  
...  

Abstract Introduction Postmortem multi-detector computed tomography (PMCT) has become an important part in forensic imaging. Modern reconstruction techniques such as iterative reconstruction (IR) are frequently used in postmortem CT angiography (PMCTA). The image quality of PMCTA depends on the strength of IR. For this purpose, we aimed to investigate the impact of different advanced IR levels on the objective and subjective PMCTA image quality. Material and methods We retrospectively analyzed the coronary arteries of 27 human cadavers undergoing whole-body postmortem CT angiography between July 2017 and March 2018 in a single center. Iterative reconstructions of the coronary arteries were processed in five different level settings (0%; 30%; 50%; 70%; 100%) by using an adaptive statistical IR method. We evaluated the objective (contrast-to-noise ratio (CNR)) and subjective image quality in several anatomical locations. Results Our results demonstrate that the increasing levels of an IR technique have relevant impact on the image quality in PMCTA scans in forensic postmortem examinations. Higher levels of IR have led to a significant reduction of image noise and therefore to a significant improvement of objective image quality (+ 70%). However, subjective image quality is inferior at higher levels of IR due to plasticized image appearance. Conclusion Objective image quality in PMCTA progressively improves with increasing level of IR with the best CNR at the highest IR level. However, subjective image quality is best at low to medium levels of IR. To obtain a “classic” image appearance with optimal image quality, PMCTAs should be reconstructed at medium levels of IR.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


2001 ◽  
Vol 30 (6) ◽  
pp. 308-313 ◽  
Author(s):  
F Gijbels ◽  
G Sanderink ◽  
C Bou Serhal ◽  
H Pauwels ◽  
R Jacobs

Sign in / Sign up

Export Citation Format

Share Document