Free-floating left atrial ball thrombus developed in an 11-year-old child with restrictive cardiomyopathy during sinus rhythm: Manifested as a major thromboembolic event

2005 ◽  
Vol 103 (1) ◽  
pp. 111-113 ◽  
Author(s):  
Hasan Turhan ◽  
Aslan Ocal ◽  
Ali Riza Erbay ◽  
Ayse Saatci Yasar ◽  
Ferit Cicekcioglu ◽  
...  
2011 ◽  
Vol 5 (1) ◽  
pp. 212-214 ◽  
Author(s):  
Jorge Ernesto Martínez Espínola ◽  
María Isabel Acosta Colmán ◽  
Osmar Antonio Centurión

An atrial thrombus is a relatively common echocardiographic finding in patients with mitral valve stenosis (MVS) and atrial fibrillation (AF). However, a “ball thrombus” or floating thrombus in the left atrium is a rare and specific entity associated with MVS. A 24-year-old woman with rheumatic MVS presented with complaints of progressive dyspnea and inferior limbs edema that began 23 days earlier after a caesarean operation for stillbirth carried out at 8 months of pregnancy. At the time of hospitalization, she was in New York Heart Association functional class III and the ECG showed sinus rhythm. Transthoracic color-flow Doppler echocardiography revealed a thick, stenotic mitral valve with a valvular area of 0.9 cm2, and an echogenic large left-atrial mass diagnosed as a free-floating left-atrial thrombus that was corroborated by transesophageal echocardiography. She refused surgery and was treated medically, and low molecular weight heparin (LMWH) (enoxaparin 80 mg/12 h) was given for 14 days and was discharged uneventfully on coumarin. Two days before discharge, a transthoracic and transesophageal ecocardiography showed disappearance of the ball thrombus uneventfully leaving spontaneous echo contrast inside the left atrium. To the best of our knowledge, this is the first case showing disappearance of a giant left atrial ball thrombus with LMWH treatment in a patient with severe MVS during sinus rhythm associated with pregnancy.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ahmet Demirkiran ◽  
Raquel P. Amier ◽  
Mark B. M. Hofman ◽  
Rob J. van der Geest ◽  
Lourens F. H. J. Robbers ◽  
...  

AbstractThe pathophysiology behind thrombus formation in paroxysmal atrial fibrillation (AF) patients is very complex. This can be due to left atrial (LA) flow changes, remodeling, or both. We investigated differences for cardiovascular magnetic resonance (CMR)-derived LA 4D flow and remodeling characteristics between paroxysmal AF patients and patients without cardiac disease. In this proof-of-concept study, the 4D flow data were acquired in 10 patients with paroxysmal AF (age = 61 ± 8 years) and 5 age/gender matched controls (age = 56 ± 1 years) during sinus rhythm. The following LA and LA appendage flow parameters were obtained: flow velocity (mean, peak), stasis defined as the relative volume with velocities < 10 cm/s, and kinetic energy (KE). Furthermore, LA global strain values were derived from b-SSFP cine images using dedicated CMR feature-tracking software. Even in sinus rhythm, LA mean and peak flow velocities over the entire cardiac cycle were significantly lower in paroxysmal AF patients compared to controls [(13.1 ± 2.4 cm/s vs. 16.7 ± 2.1 cm/s, p = 0.01) and (19.3 ± 4.7 cm/s vs. 26.8 ± 5.5 cm/s, p = 0.02), respectively]. Moreover, paroxysmal AF patients expressed more stasis of blood than controls both in the LA (43.2 ± 10.8% vs. 27.8 ± 7.9%, p = 0.01) and in the LA appendage (73.3 ± 5.7% vs. 52.8 ± 16.2%, p = 0.04). With respect to energetics, paroxysmal AF patients demonstrated lower mean and peak KE values (indexed to maximum LA volume) than controls. No significant differences were observed for LA volume, function, and strain parameters between the groups. Global LA flow dynamics in paroxysmal AF patients appear to be impaired including mean/peak flow velocity, stasis fraction, and KE, partly independent of LA remodeling. This pathophysiological flow pattern may be of clinical value to explain the increased incidence of thromboembolic events in paroxysmal AF patients, in the absence of actual AF or LA remodeling.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Kupczynska ◽  
D Miskowiec ◽  
B Michalski ◽  
L Szyda ◽  
K Wierzbowska-Drabik ◽  
...  

Abstract Background Atrial fibrillation (AF) impairs mechanical function of the heart, especially atria and restoration of sinus rhythm (SR) leads to improvement of mechanics. The predicting role of changes in strain parameters for AF recurrence is not established yet. Purpose To analyse changes in left atrial (LA) and left ventricular (LV) mechanical function after conversion to SR and their prognostic values for AF recurrence during 24 months follow-up. Methods Prospective study involved 59 patients after successful electrical cardioversion (EC) because of nonvalvular AF (mean age 65±4 years, 47% female). Speckle tracking analysis (STE) was applied to calculate longitudinal strain of LV and LA before EC and within 24 hours after restoration of SR and additionally total left heart strain (TS) defined as a sum of absolute peak LV and LA strain. We calculated change in strain between AF and SR analyses expressed as delta (Δ). During follow-up we noticed AF recurrence in 42 (71%) patients, most of them (93%) during 1st year after EC. Median time of AF recurrence was 3 months. Results We noticed significant immediate post-EC improvement in peak LA longitudinal strain (PALS) and LV global longitudinal strain (LVGLS) (table). Unlike CHA2DS2-VASc score, strain parameters were predictors of AF recurrence. Every 1% increment in ΔLVGLS was related with 13% increase in AF recurrence risk (p=0.02) and every 1% increment in ΔPALS and ΔTS were related with 9% decrease in AF recurrence risk (p=0.007 and p=0.0014, respectively). Multivariate analysis revealed ΔTS as a strongest predictor with 9% decrease in AF risk per every 1% increment. The criterion of ΔTS ≤7.5% allows to predict AF recurrence with 81% sensitivity and 63% specificity. Conclusions Speckle tracking measurements are able to detect early mechanical changes in LA even within 24 hours of SR and these absolute changes in LVGLS as well as PALS can predict AF recurrence, with optimal stratification by novel parameter - TS. Funding Acknowledgement Type of funding source: None


Medicina ◽  
2021 ◽  
Vol 57 (6) ◽  
pp. 554
Author(s):  
Stefan Naydenov ◽  
Nikolay Runev ◽  
Emil Manov

Background and Objectives: Patients with atrial fibrillation (AF), lasting >48 h, considered for cardioversion, are recommended ≥3 weeks of oral anticoagulation before sinus rhythm restoration because of high risk of development of left atrial thrombosis (LAT) and stroke. However, the optimal duration of anticoagulation in the presence of overt LAT is unknown. Materials and Methods: An open-label study aimed to investigate the prevalence of spontaneous echo contrast (SEC) and LAT before and after 3 weeks of direct oral anticoagulant (DOAC) treatment. We included 51 consecutive patients (50.9% males), mean age 69.3 ± 7.4 years with paroxysmal/unknown duration of AF, considered for cardioversion, who agreed to have transesophageal echocardiography at enrollment and 3 weeks later. Results: At baseline SEC was present in 26 (50.9%) and LAT in 10 (19.6%) of 51 patients. After 3 weeks on DOAC, SEC persisted in 12 (25.0%) and LAT in 7 (14.5%) of 48 patients, p < 0.05 vs. baseline. Factors, associated most strongly with persistence of SEC/LAT, were left atrial appendage (LAA) emptying velocity <20 cm/s (OR = 2.82), LAA lobes >2 (OR = 1.84), and indexed left atrial volume ≥34 mL/m2 (OR = 1.37). Conclusions: In our study the incidence of SEC/LAT, particularly in AF with unknown duration, was not as low as we expected. The prevalence of SEC/LAT seemed to be dependent on factors not routinely evaluated in AF patients planned for cardioversion (indexed LA volume, LAA morphology and number of lobules, LAA emptying velocity, etc.). Our data suggested an individualized approach for DOAC duration in AF patients before an attempt for restoration of sinus rhythm is made, taking into consideration the LAA morphology and function.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Marco Spartera ◽  
Guilherme Pessoa-Amorim ◽  
Antonio Stracquadanio ◽  
Adam Von Ende ◽  
Alison Fletcher ◽  
...  

Abstract Background Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows sophisticated quantification of left atrial (LA) blood flow, and could yield novel biomarkers of propensity for intra-cardiac thrombus formation and embolic stroke. As reproducibility is critically important to diagnostic performance, we systematically investigated technical and temporal variation of LA 4D flow in atrial fibrillation (AF) and sinus rhythm (SR). Methods Eighty-six subjects (SR, n = 64; AF, n = 22) with wide-ranging stroke risk (CHA2DS2VASc 0–6) underwent LA 4D flow assessment of peak and mean velocity, vorticity, vortex volume, and stasis. Eighty-five (99%) underwent a second acquisition within the same session, and 74 (86%) also returned at 30 (27–35) days for an interval scan. We assessed variability attributable to manual contouring (intra- and inter-observer), and subject repositioning and reacquisition of data, both within the same session (same-day scan–rescan), and over time (interval scan). Within-subject coefficients of variation (CV) and bootstrapped 95% CIs were calculated and compared. Results Same-day scan–rescan CVs were 6% for peak velocity, 5% for mean velocity, 7% for vorticity, 9% for vortex volume, and 10% for stasis, and were similar between SR and AF subjects (all p > 0.05). Interval-scan variability was similar to same-day scan–rescan variability for peak velocity, vorticity, and vortex volume (all p > 0.05), and higher for stasis and mean velocity (interval scan CVs of 14% and 8%, respectively, both p < 0.05). Longitudinal changes in heart rate and blood pressure at the interval scan in the same subjects were associated with significantly higher variability for LA stasis (p = 0.024), but not for the remaining flow parameters (all p > 0.05). SR subjects showed significantly greater interval-scan variability than AF patients for mean velocity, vortex volume, and stasis (all p < 0.05), but not peak velocity or vorticity (both p > 0.05). Conclusions LA peak velocity and vorticity are the most reproducible and temporally stable novel LA 4D flow biomarkers, and are robust to changes in heart rate, blood pressure, and differences in heart rhythm.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
S Ijuin ◽  
A Hamadanchi ◽  
F Haertel ◽  
L Baez ◽  
C Schulze ◽  
...  

Abstract Background Percutaneous left atrial appendage closure (LAAC) is being established as an alternative option for atrial fibrillation (AF) patients with high bleeding risk. Few studies reported the influence of percutaneous LAAC on left atrial (LA) performance, but most of the studies demonstrated no remarkable changes in their parameters after the procedure. Method The study included 95 patients (age: 75±6.7 years, 67% male) whom underwent percutaneous LAAC in a single center between September 2012 and November 2018. LA strain was evaluated at three different time intervals by transesophageal echocardiography (baseline, 45 days and 180 days after procedure). All data were analyzed using a dedicated. 70 patients had atrial fibrillation whereas 25 were in sinus rhythm. Analysis was performed for peak atrial longitudinal strain (PALS) and peak atrial contraction strain (PACS) from segment of lateral wall in mid-esophageal 4 chamber view. The validity of lateral wall left atrial analysis was recently shown by our group. PACS was obtained in patients with sinus rhythm during exams. Results Compared to baseline, PALS was significantly increased after 45 days (12.4±8.4% vs 16.0±10.7%, p=0.001) and remained stable after 180 days (13.8±9.0% vs 17.0±12.4%, p=0.098). Even in only patients with atrial fibrillation during exams, it was increased (10.8±7.7% vs 13.4±7.1%, p=0.012 and 8.5±5.1% vs 13.9±8.1%, p=0.014). Similarly, compared with the baseline, PACS was significantly increased after 45 days and 180 days (5.8±3.9% vs 10.6±7.6%, p=0.001 and 4.5±2.6% vs 7.9±3.1%, p=0.036). The Changes in PALS and PACS Conclusion Our study has demonstrated for the first time the improvement in LA strain following LAAC within 45 days of implantation by transesophageal echocardiography and these values were maintained at least for 6 months. Further appraisal is warranted for confirmation of these preliminary findings.


Sign in / Sign up

Export Citation Format

Share Document