Improving stability and thermal properties of TiO2 nanofluids by supramolecular modification: high energy efficiency heat transfer medium for data center cooling system

Author(s):  
Yixin Wang ◽  
Changjun Zou ◽  
Wenjing Li ◽  
Yiduo Zou ◽  
Hanxiang Huang
Author(s):  
Kamran Nazir ◽  
Naveed Durrani ◽  
Imran Akhtar ◽  
M. Saif Ullah Khalid

Due to high energy demands of data centers and the energy crisis throughout the world, efficient heat transfer in a data center is an active research area. Until now major emphasis lies upon study of air flow rate and temperature profiles for different rack configurations and tile layouts. In current work, we consider different hot aisle (HA) and cold aisle (CA) configurations to study heat transfer phenomenon inside a data center. In raised floor data centers when rows of racks are parallel to each other, in a conventional cooling system, there are equal number of hot and cold aisles for odd number of rows of racks. For even number of rows of racks, whatever configuration of hot/cold aisles is adopted, number of cold aisles is either one greater or one less than number of hot aisles i.e. two cases are possible case A: n(CA) = n(HA) + 1 and case B: n(CA) = n(HA) − 1 where n(CA), n(HA) denotes number of cold and hot aisles respectively. We perform numerical simulations for two (case1) and four (case 2) racks data center. The assumption of constant pressure below plenum reduces the problem domain to above plenum area only. In order to see which configuration provides higher heat transfer across servers, we measure heat transfer across servers on the basis of temperature differences across racks, and in order to validate them, we find mass flow rates on rack outlet. On the basis of results obtained, we conclude that for even numbered rows of rack data center, using more cold aisles than hot aisles provide higher heat transfer across servers. These results provide guidance on the design and layout of a data center.


2008 ◽  
Vol 130 (2) ◽  
Author(s):  
Amip J. Shah ◽  
Van P. Carey ◽  
Cullen E. Bash ◽  
Chandrakant D. Patel

The modeling of recirculation patterns in air-cooled data centers is of interest to ensure adequate thermal management of computer racks at increased heat densities. Most metrics that describe recirculation are based exclusively on temperature inside the data center, and therefore fail to provide adequate information regarding the energy efficiency of the thermal infrastructure. This paper addresses this limitation through an exergy analysis of the data center thermal management system. The approach recognizes that the mixing of hot and cold streams in the data center airspace is an irreversible process and must therefore lead to a loss of exergy. Experimental validation in a test data center confirms that such an exergy-based characterization in the cold aisle reflects the same recirculation trends as suggested by traditional temperature-based metrics. Further, by extending the exergy-based model to include irreversibilities from other components of the thermal architecture, it becomes possible to quantify the amount of available energy supplied to the cooling system that is being utilized for thermal management purposes. The energy efficiency of the entire data center cooling system can then be collapsed into the single metric of net exergy loss. When evaluated against a ground state of the external ambience, this metric enables an estimate of how much of the energy emitted into the environment could potentially be harnessed in the form of useful work. Thus, this paper successfully demonstrates that the proposed exergy-based approach can provide a foundation upon which the data center cooling system can be simultaneously evaluated for thermal manageability and energy efficiency.


2018 ◽  
Vol 180 ◽  
pp. 02012
Author(s):  
Janusz Biliński

High energy efficiency and increasing the working frequency of the converter will make it possible to minimize the size of the cooling system and reduce energy consumption. The use of the SiC technology in propulsion drives increases the efficiency of the converter by 1÷1.5%. Simultaneously, higher working frequency reduces losses in the traction motor, significantly lowering the cost of the energy consumed by the vehicle. Auxiliary converters using the SiC technology are a new quality. The reduction of weight and size is very significant (ca. 40÷50%). Higher switching frequency reduces the size of magnetic components (ca. 80%), and higher converter efficiency minimizes the size of the cooling system. The overall efficiency of the converter is extremely high (94÷96%). This paper presents comparison of Si and SiC parameters which are important for modern EV solutions. Paper presents also parameters of SiC traction inverter and auxiliary converter, designed and manufactured as state-of-the-art product for modern electric bus.


Author(s):  
Thomas J. Breen ◽  
Ed J. Walsh ◽  
Jeff Punch ◽  
Amip J. Shah ◽  
Cullen E. Bash ◽  
...  

In the drive to enhance data center energy efficiency, much attention has been placed on the prospect of airflow containment in hot-aisle cold-aisle raised floor arrangements. Such containment prevents airflow recirculation, eliminating the mixing effects of the hot and cold air streams that can cause an undesirable temperature rise at the inlet of the equipment racks. The intuitive assessment of the industry has been that the elimination of such mixing effects increases the energy efficiency of the data center cooling system by enabling delivery of air at higher inlet temperatures, thus reducing the amount of infrastructure cooling required. This paper employs an end-to-end modeling approach to analyze the effect of air stream containment in the computer room and its impact on the holistic system efficiency. Dimensionless heat index parameters are employed to characterize the effects of containment, recirculation and mixing within the computer room environment. The extent of recirculation is shown to primarily influence the operation of the rack and CRAC level cooling systems, with the chiller systems also impacted. The overall effect on the complete cooling system performance and data center efficiency requires balancing of these effects. Through this model analysis, it is shown that containment may negatively impact overall energy efficiency in some circumstances, and that recirculation may actually be beneficial to overall energy efficiency under certain system dependent operating thresholds.


2012 ◽  
Vol 134 (4) ◽  
Author(s):  
Thomas J. Breen ◽  
Ed J. Walsh ◽  
Jeff Punch ◽  
Amip J. Shah ◽  
Cullen E. Bash ◽  
...  

In the drive to enhance data center energy efficiency, much attention has been placed on the prospect of airflow containment in hot-aisle cold-aisle raised floor arrangements. Such containment prevents airflow recirculation, eliminating the mixing effects of the hot and cold air streams that can cause an undesirable temperature rise at the inlet of the equipment racks. The intuitive assessment of the industry has been that the elimination of such mixing effects increases the energy efficiency of the data center cooling system by enabling delivery of air at higher inlet temperatures, thus reducing the amount of infrastructure cooling required. This paper employs an end-to-end modeling approach to analyze the effect of air stream containment in the computer room and its impact on the holistic system efficiency. Dimensionless heat index parameters are employed to characterize the effects of containment, recirculation, and mixing within the computer room environment. The extent of recirculation is shown to primarily influence the operation of the rack and computer room air conditioning (CRAC) level cooling systems, with the chiller systems also impacted. The overall effect on the complete cooling system performance and data center efficiency requires balancing of these effects. Through this model analysis, it is shown that containment may negatively impact overall energy efficiency in some circumstances, and that recirculation may actually be beneficial to overall energy efficiency under certain system dependent operating thresholds.


2018 ◽  
Author(s):  
Tao Wang ◽  
Yuhua Li ◽  
Huan Liu ◽  
Lei Zhang ◽  
Yuyan Jiang ◽  
...  

Author(s):  
Xiaoyan Wang ◽  
Jinmei Du ◽  
Changhai Xu

Abstract:: Activated peroxide systems are formed by adding so-called bleach activators to aqueous solution of hydrogen peroxide, developed in the seventies of the last century for use in domestic laundry for their high energy efficiency and introduced at the beginning of the 21st century to the textile industry as an approach toward overcoming the extensive energy consumption in bleaching. In activated peroxide systems, bleach activators undergo perhydrolysis to generate more kinetically active peracids that enable bleaching under milder conditions while hydrolysis of bleach activators and decomposition of peracids may occur as side reactions to weaken the bleaching efficiency. This mini-review aims to summarize these competitive reactions in activated peroxide systems and their influence on bleaching performance.