Nucleate pool boiling, film boiling and single-phase free convection at pressures up to the critical state. Part II: Circumferential variation of the wall superheat for a horizontal 25mm copper cylinder

2010 ◽  
Vol 33 (7) ◽  
pp. 1251-1263 ◽  
Author(s):  
Dieter Gorenflo ◽  
Elmar Baumhögger ◽  
Thorsten Windmann ◽  
Gerhard Herres
2013 ◽  
Vol 135 (6) ◽  
Author(s):  
Vijay K. Dhir ◽  
Gopinath R. Warrier ◽  
Eduardo Aktinol

A review of numerical simulation of pool boiling is presented. Details of the numerical models and results obtained for single bubble, multiple bubbles, nucleate boiling, and film boiling are provided. The effect of such parameters such as wall superheat, liquid subcooling, contact angle, gravity level, noncondensables, and conjugate heat transfer are also included. The numerical simulation results have been validated with data from well designed experiments.


1999 ◽  
Author(s):  
Daiju Motoya ◽  
Ikuya Haze ◽  
Masahiro Osakabe

Abstract Nucleate pool boiling of water on clean and fouling surfaces was conducted in microgravity and earth gravity. The microgravity experiments were conducted in 8 s JAMIC drop shaft in Hokkaido of Japan. Platinum wires of 0.2 mm in diameter with or without fouling scale were used to provide uniform heat flux and measurement of the mean temperature of wires. The generated bubble volume was measured with high-speed video or CCD images. The more vigorous bubbling was observed on the fouling wire compared to that on the clean wire at a same heat flux both in earth gravity and microgravity. The enhancement of the bubbling was associated with the fact that the hydrophilic porous structure in the fouling scale provided the sufficient number of active sites for bubbling nucleation. The wettability of the surface with the fouling scale was much higher than that of the clean bare surface. The bubble departure diameter on the fouling wire was smaller due to the high wettability than that on the clean wire. The latent heat transportation ratio to the total heat flux was calculated with the generated bubble volume measured with high-speed video or CCD images. The ratio was approximately the same at the clean and fouling wires in spite of the apparent difference in bubbling behavior, but it was significantly affected with the gravity level. The ratio increased with an increase of the heat flux in the earth gravity but it remained at the smaller value in the microgravity. The nucleate heat transfer coefficient on the bare surface did not depend on the gravity levels although the bubbling behavior strongly affected with the gravity level. As the wire radius is small compared to the capillary length scale in microgravity, a growing and coalescing bubble sometimes completely covered the clean wire, evaporating all liquid in contact with the surface and inducing a transition to film boiling. However, on the fouling wire, many small bubbles were generated and sprang from the surface in various directions in microgravity. The spring out action of bubbles suppressed the transition to the film boiling on the fouling wire in the present experimental range.


1996 ◽  
Vol 118 (3) ◽  
pp. 654-661 ◽  
Author(s):  
E. K. Ungar ◽  
R. Eichhorn

Pool boiling heat flux versus wall superheat boiling curves were obtained for horizontal 3.18-mm-dia thin-walled brass tubes heated by an internal high-speed flow of ethylene glycol. The boiling liquids were saturated n-pentane, R-113, acetone, methanol ethanol, benzene, and isopropanol. Boiling results include nucleate and transition boiling in all the test liquids, but film boiling was achieved only with methanol. The measured peak heat fluxes are well correlated by available predictions. The methanol experiments clearly display two transition boiling curves, one obtained on increasing the cylinder temperature from nucleate boiling, the other on decreasing the cylinder temperature from film boiling. For the cases in which the highest cylinder temperature reached only into the transition regime, a single transition boiling curve resulted.


Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3893
Author(s):  
Mohd Danish ◽  
Mohammed K. Al Mesfer ◽  
Khursheed B. Ansari ◽  
Mudassir Hasan ◽  
Abdelfattah Amari ◽  
...  

In the current work, the heat flux in nucleate pool boiling has been predicted using the macrolayer and latent heat evaporation model. The wall superheat (ΔT) and macrolayer thickness (δ) are the parameters considered for predicting the heat flux. The influence of operating parameters on instantaneous conduction heat flux and average heat flux across the macrolayer are investigated. A comparison of the findings of current model with Bhat’s decreasing macrolayer model revealed a close agreement under the nucleate pool boiling condition at high heat flux. It is suggested that conduction heat transfer strongly rely on macrolayer thickness and wall superheat. The wall superheat and macrolayer thickness is found to significantly contribute to conduction heat transfer. The predicted results closely agree with the findings of Bhat’s decreasing macrolayer model for higher values of wall superheat signifying the nucleate boiling. The predicted results of the proposed model and Bhat’s existing model are validated by the experimental data. The findings also endorse the claim that predominant mode of heat transfer from heater surface to boiling liquid is the conduction across the macrolayer at the significantly high heat flux region of nucleate boiling.


Processes ◽  
2019 ◽  
Vol 7 (10) ◽  
pp. 726
Author(s):  
Mohd Danish ◽  
Mohammed Al Mesfer

A mathematical model has been developed for heat exchange in nucleate boiling at high flux applying an energy balance on a macrolayer. The wall superheat, macrolayer thickness, and time are the parameters considered for predicting the heat flux. The influence of the wall superheat and macrolayer thickness on average heat flux has been predicted. The outcomes of the current model have been compared with Bhat’s constant macrolayer model, and it was found that these models are in close agreement corresponding to the nucleate pool boiling regime. It was concluded that the wall superheat and macrolayer thickness contributed significantly to conduction heat transfer. The average conduction heat fluxes predicted by the current model and by Bhat’s model are in close agreement for a thinner macrolayer of approximately 50 µm. For higher values of the wall superheat, which corresponds to the nucleate pool boiling condition, the predicted results strongly agree with the results of Bhat’s model. The findings also validate the claim that conduction across the macrolayer accounts for the main heat transfer mode from the heater surface to boiling liquid at high heat flux in nucleate pool boiling.


Author(s):  
Nanxi Li ◽  
Amy Rachel Betz

Boiling is an efficient way to transfer heat due to the latent heat of vaporization. Many variables, such as surface properties, fluid properties, and system pressure, will affect the performance of pool boiling. Enhanced pool boiling has extensive applications in chemical, microelectronics, and power industries. Previous research has shown that micro- or nanostructured surfaces and coated surfaces will increase heat transfer coefficients up to one order of magnitude at atmospheric pressure. Graphene as a very good material with superb mechanical and electrical properties also has potential to enhance pool boiling performance. The purpose of this research is to investigate heat transfer enhancement on a graphene coated surface compared to a plane copper surface at atmospheric pressure and increased pressures with deionized water. The effect of the graphene coating on the critical heat flux is also investigated. To carry out the experiments, we designed and fabricated a special experimental facility that will withstand the high pressures (up to 20 bar) and high temperatures. Graphene is coated on a 1 cm2 copper surface using spray coating. The boiling vessel is pressurized with nitrogen and the system pressure is controlled by a back pressure regulator. The test fluid is preheated to saturation temperature by two 500 W cartridge heaters. Multiple 150 W cartridge heaters are inserted in a copper cylinder to provide wall superheat for bubbles to nucleate on the studied surface. When the system reaches steady state, a process controller controls these cartridge heaters to increase the heat flux gradually from 0 kW/m2 to the critical heat flux. The copper cylinder is insulated with PTFE to minimize heat loss from the side. The gap between the copper cylinder and the insulation surface is carefully sealed with high temperature epoxy to reduce undesired nucleation sites. The wall superheat corresponding to each heat flux is extrapolated using Fourier’s law from three thermocouple readings. The heat transfer coefficient can thus be calculated at each heat flux for the every test fluid at its corresponding pressure. A camera with 3.2 cm field of view at a working distance of 12 cm to 15 cm is used to visualize the bubble formation on the heated surface.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2313
Author(s):  
Abhishek Kumar ◽  
Kuo-Shu Hung ◽  
Chi-Chuan Wang

In the present experimental study, nucleate pool boiling heat transfer measurements of two high-flux tubes (sample A and sample B) were conducted at atmospheric pressure with HFE-7200 as the working fluid. Both high-flux tubes were made from a sintered Cu-Ni (high-flux) alloy powder. The porous high-flux surface was coated inside the test tube and it is tested within the heat flux ranging from 2.6 to 86 kW/m2. The major difference between sample A and sample B was the coating thickness, where sample B (0.6 mm) was much larger than that of sample A (0.07 mm). Both tubes showed about three times enhancement in heat transfer coefficient (HTC) when compared to plain tube. Even though sample B contained a higher HTC than sample A, it also revealed a faster level-off phenomenon regarding the HTC vs. wall superheat. The major parameter which characterizes the boiling performance of high-flux tube was the ratio of coating thickness to pore diameter which also yielded different trends upon HTC vs. wall superheat amid sample A and B. It was found that the porous based Nishikawa correlation can well predict the performance of sample A but not sample B. This is because the ratio of coating thickness to pore diameter is far outside the applicable range of the Nishikawa correlation. Hence, a modified Nishikawa correlation is proposed. The predicted capability of the proposed modified Nishikawa correlation against sample A and sample for HTC was within ±28% deviation. The standard mean deviation of the Nishikawa correlation with experimental data for sample A and sample B was 0.302 (12.48%) and 5.64 (73%), respectively.


Sign in / Sign up

Export Citation Format

Share Document