Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies

Injury ◽  
2018 ◽  
Vol 49 (4) ◽  
pp. 753-765 ◽  
Author(s):  
Martijn H. Hulsmans ◽  
Mark van Heijl ◽  
Roderick M. Houwert ◽  
Bart J. Burger ◽  
Egbert Jan.M. Verleisdonk ◽  
...  
Author(s):  
Ayobobola A. Apampa ◽  
Ayesha Ali ◽  
Bryar Kadir ◽  
Zubair Ahmed

Abstract Purpose The objective of this systematic review is to compare the safety and efficacy of surgical fixation of rib fractures against non-surgical interventions for the treatment of flail chest in the adult population. Methods A search was performed on the 22nd of July 2020 to identify articles comparing surgical fixation versus clinical management for flail chest in adults, with a description of the outcome parameters (resource utility, mortality, adverse effects of the intervention and adverse progression in pulmonary status). Relevant randomised controlled trials were selected, their risk of bias assessed, and the data then extracted and analysed. Results 157 patients were included from four studies in the analyses, with 79 and 78 patients in the surgical and non-surgical groups, respectively. The pooled effects of all outcomes tended towards favouring surgical intervention. Surgical intervention was associated with lower rates of pneumonia (I2 = 46%, Tau2 = 0.16, p = 0.16), significantly lower rates of tracheostomy (I2 = 76%, Tau2 = 0.67, p = 0.02), and a significantly lower duration of mechanical ventilation (I2 = 88%, Tau2 = 33.7, p < 0.01) in comparison to the non-surgical management methods. Conclusion Our results suggest that surgical intervention reduces the need for tracheostomy, reduces the time spent in the intensive care unit following a traumatic flail chest injury and could reduce the risk of acquiring pneumonia after such an event. There is a need for further well-designed studies with sufficient sample sizes to confirm the results of this study and also detect other possible effects of surgical intervention in the treatment of traumatic flail chest in adults.


2020 ◽  
Author(s):  
Paul Hoogervorst ◽  
Tess van Dam ◽  
Nico Verdonschot ◽  
Gerjon Hannink

Abstract Background An alternative to the current gold standard in operative treatment of displaced midshaft clavicle fractures (DMCF) using plate osteosynthesis, is internal fixation by means of intramedullary fixation devices. These devices differ considerably in their specifications and characteristics. The aim of this systematic review is to generate an overview of functional outcomes and complications in the management of DMCF per available intramedullary device.Methods A systematic review was conducted to identify all papers reporting functional outcomes, union rates and/or complications using an intramedullary fixation device for the management of midshaft clavicle fractures. Multiple databases and trial registries were searched from inception until February 2020. Meta-analysis was conducted based on functional outcomes and type of complication per type of intramedullary fixation device. Pooled estimates of functional outcomes scores and incidence of complications were calculated using a random effects model. Risk of bias and quality was assessed using the Cochrane risk of bias and ROBINS-I tools. The confidence in estimates were rated and described according to the recommendations of the GRADE working group.Results Sixty-seven studies were included in this systematic review. The majority of studies report on the use of Titanium Elastic Nails (TEN). At 12 months follow up the Titanium Elastic Nail and Sonoma CRx report an average Constant-Murley score of 94.4 (95%CI 93-95) and 94.0 (95%CI 92-95) respectively (GRADE High). The most common reported complications after intramedullary fixation are implant-related and implant-specific. For the TEN, hardware irritation and protrusion, telescoping or migration, with a reported pooled incidence 20% (95%CI 14-26) and 12% (95%CI 8-18), are most common (GRADE Moderate). For the Rockwood/Hagie Pin, hardware irritation is identified as the most common complication with 22% (95%CI 13-35) (GRADE Low). The most common complication for the Sonoma CRx was cosmetic dissatisfaction in 6% (95%CI 2-17) of cases (GRADE Very low). Conclusion Although most studies were of low quality, good functional results and union rates irrespective of the type of device are found. However, there are clear device-related and device-specific complications for each. The results of this systematic review and meta-analysis can help guide surgeons in choosing the appropriate operative strategy, implant and informing their patient.


BMJ Open ◽  
2019 ◽  
Vol 9 (5) ◽  
pp. e024737
Author(s):  
Alison Booth ◽  
Helen Margaret Ann Ingoe ◽  
Matthew Northgraves ◽  
Elizabeth Coleman ◽  
Melissa Harden ◽  
...  

ObjectivesTo undertake a systematic review of the evidence base for the effectiveness of surgical fixation of lateral compression (LC-1) fragility fractures of the pelvis compared with non-surgical approaches.SearchesMEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials and two international trials registers were searched up to January 2017 (MEDLINE to February 2019) for studies of internal or external fixation of fragility fractures of the pelvis.ParticipantsPatients with lateral compression pelvic fractures, sustained as the result of a low-energy mechanism, defined as a fall from standing height or less.InterventionsSurgery using either external or internal fixation devices. Conservative non-surgical treatment was the defined comparator.Outcome measuresOutcomes of interest were patient mobility and function, pain, quality of life, fracture union, mortality, hospital length of stay and complications (additional operative procedures, number and type of adverse events and serious adverse events).Quality assessment and synthesisThe Joanna Briggs Institute Checklist for Case Series was used to assess the included studies. Results were presented in a narrative synthesis.ResultsOf 3421 records identified, four retrospective case series met the inclusion criteria. Fixation types were not consistent between studies or within studies and most patients had more than one type of pelvic fixation. Where reported, mobility and function improved post-surgery, and a reduction in pain was recorded. Length of hospital stay ranged from 4 days to 54 days for surgical fixation of any type. Reported complications and adverse outcomes included: infections, implant loosening, pneumonia and thrombosis. Use of analgesia was not reported.ConclusionsThere is insufficient evidence to support guidance on the most effective treatment for patients who fail to mobilise after sustaining an LC-1 fragility fracture.Trial registration numberCRD42017055872.


2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
Enzhe Zhao ◽  
Rui Zhang ◽  
Dou Wu ◽  
Yao Guo ◽  
Qiang Liu

Objective. The aim of this study was to compare the functional outcome and complications in midshaft clavicle fractures receiving minimally invasive plate osteosynthesis and conventional open plating. Methods. Relevant studies were searched in the databases of Medline, EMBASE, Cochrane Library, Ovid, and Web of Science from inception to March 1, 2019. Pooled data were analyzed with Cochrane Collaboration’s Review Manager 5.3. Results. A total of 7 studies were included, of which 2 were randomized controlled trials, 3 were retrospective cohort studies, and 2 were prospective cohort studies including 316 patients. No statistical differences in functional outcome (weighted mean difference [WMD] = 0.99, P=0.12), operation time (WMD = −10.44, P=0.07) and time to bone union (WMD = −0.23, P=0.70) were observed between the two groups. However, minimally invasive plate osteosynthesis reduced rates of skin numbness (odds ratio (OR) = 0.25, 95% CI : 0.13 to 0.48; P<0.0001) and complications (OR = 0.33, 95% CI : 0.16 to 0.71; P=0.005) compared with conventional open plating. Conclusion. This systematic review and meta-analysis found no differences in terms of functional outcomes, operation time, and fracture healing time between minimally invasive plate osteosynthesis and conventional open plating. However, minimally invasive plate osteosynthesis had apparent advantages in rates of skin numbness and complications.


2021 ◽  
Vol 2 (8) ◽  
pp. 646-654
Author(s):  
John R. Martin ◽  
Patrick E. Saunders ◽  
Mark Phillips ◽  
Sean M. Mitchell ◽  
Michael D. Mckee ◽  
...  

Aims The aims of this network meta-analysis (NMA) were to examine nonunion rates and functional outcomes following various operative and nonoperative treatments for displaced mid-shaft clavicle fractures. Methods Initial search strategy incorporated MEDLINE, PubMed, Embase, and the Cochrane Library for relevant randomized controlled trials (RCTs). Four treatment arms were created: nonoperative (NO); intramedullary nailing (IMN); reconstruction plating (RP); and compression/pre-contoured plating (CP). A Bayesian NMA was conducted to compare all treatment options for outcomes of nonunion, malunion, and function using the Disabilities of the Arm Shoulder and Hand (DASH) and Constant-Murley Shoulder Outcome scores. Results In all, 19 RCTs consisting of 1,783 clavicle fractures were included in the NMA. All surgical options demonstrated a significantly lower odds ratio (OR) of nonunion in comparison to nonoperative management: CP versus NO (OR 0.08; 95% confidence interval (CI) 0.04 to 0.17); IMN versus NO (OR 0.07; 95% CI 0.02 to 0.19); RP versus NO (OR 0.07; 95% CI: 0.01 to 0.24). Compression plating was the only treatment to demonstrate significantly lower DASH scores relative to NO at six weeks (mean difference -10.97; 95% CI -20.69 to 1.47). Conclusion Surgical fixation demonstrated a lower risk of nonunion compared to nonoperative management. Compression plating resulted in significantly less disability early after surgery compared to nonoperative management. These results demonstrate possible early improved functional outcomes with compression plating compared to nonoperative treatment. Surgical fixation of mid-shaft clavicle fractures with compression plating may result in quicker return to activity by rendering patients less disabled early after surgery. Cite this article: Bone Jt Open 2021;2(8):646–654.


Sign in / Sign up

Export Citation Format

Share Document