Insertion depth in power-weight trees

2021 ◽  
pp. 106227
Author(s):  
Merritt Lyon ◽  
Hosam Mahmoud
Keyword(s):  
1994 ◽  
Vol 110 (1) ◽  
pp. 64-74 ◽  
Author(s):  
D DIRKS ◽  
J AHLSTROM ◽  
L EISENBERG

2021 ◽  
pp. 014556132098051
Author(s):  
Matula Tareerath ◽  
Peerachatra Mangmeesri

Objectives: To retrospectively investigate the reliability of the age-based formula, year/4 + 3.5 mm in predicting size and year/2 + 12 cm in predicting insertion depth of preformed endotracheal tubes in children and correlate these data with the body mass index. Patients and Methods: Patients were classified into 4 groups according to their nutritional status: thinness, normal weight, overweight, and obesity; we then retrospectively compared the actual size of endotracheal tube and insertion depth to the predicting age-based formula and to the respective bend-to-tip distance of the used preformed tubes. Results: Altogether, 300 patients were included. The actual endotracheal tube size corresponded with the Motoyama formula (64.7%, 90% CI: 60.0-69.1), except for thin patients, where the calculated size was too large (0.5 mm). The insertion depth could be predicted within the range of the bend-to-tip distance and age-based formula in 85.0% (90% CI: 81.3-88.0) of patients. Conclusion: Prediction of the size of cuffed preformed endotracheal tubes using the formula of Motoyama was accurate in most patients, except in thin patients (body mass index < −2 SD). The insertion depth of the tubes was mostly in the range of the age-based-formula to the bend-to-tip distance.


Membranes ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 192
Author(s):  
Kinga Burdach ◽  
Dagmara Tymecka ◽  
Aneta Urban ◽  
Robert Lasek ◽  
Dariusz Bartosik ◽  
...  

The increasing resistance of bacteria to available antibiotics has stimulated the search for new antimicrobial compounds with less specific mechanisms of action. These include the ability to disrupt the structure of the cell membrane, which in turn leads to its damage. In this context, amphiphilic lipopeptides belong to the class of the compounds which may fulfill this requirement. In this paper, we describe two linear analogues of battacin with modified acyl chains to tune the balance between the hydrophilic and hydrophobic portion of lipopeptides. We demonstrate that both compounds display antimicrobial activity with the lowest values of minimum inhibitory concentrations found for Gram-positive pathogens. Therefore, their mechanism of action was evaluated on a molecular level using model lipid films mimicking the membrane of Gram-positive bacteria. The surface pressure measurements revealed that both lipopeptides show ability to bind and incorporate into the lipid monolayers, resulting in decreased ordering of lipids and membrane fluidization. Atomic force microscopy (AFM) imaging demonstrated that the exposure of the model bilayers to lipopeptides leads to a transition from the ordered gel phase to disordered liquid crystalline phase. This observation was confirmed by attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) results, which revealed that lipopeptide action causes a substantial increase in the average tilt angle of lipid acyl chains with respect to the surface normal to compensate for lipopeptide insertion into the membrane. Moreover, the peptide moieties in both molecules do not adopt any well-defined secondary structure upon binding with the lipid membrane. It was also observed that a small difference in the structure of a lipophilic chain, altering the balance between hydrophobic and hydrophilic portion of the molecules, results in different insertion depth of the active compounds.


2021 ◽  
Vol 13 (2) ◽  
pp. 168781402199439
Author(s):  
Baofeng Tu ◽  
Bin Xuan ◽  
Chuanpeng Li ◽  
Xinyu Zhang ◽  
Jun Hu

A distortion generator equipped with a motor-activated movable flat baffle was installed just upstream of a rectangular plenum entrance to investigate the effects of inlet total pressure distortion on the stability and performance of an auxiliary power unit (APU). Experiments and numerical simulations on a direct connect scale inlet model of the APU were carried out to obtain a quantitative relationship between the insertion depth of the flat baffle in the flow stream and the total pressure distortion intensity and region. In the experiments, the blocking coefficient and total pressure distortion coefficient were controlled by adjusting the insertion depth of the flat baffle and the mass flow. In the simulations, detailed flow field was analyzed based on the detached-eddy simulation (DES) method. The results show that the pressure distribution of the distorted flow on the aerodynamic interface plane (AIP) can be divided into a high-pressure region, a transition region, and a low-pressure region. The area affected by the distorted flow was larger than the inserting area of the flat baffle. That area was more related to the relative blocking coefficient, and less affected by the mass flow. The total pressure distortion coefficient had a linear relationship with the mass flow rate and is positively correlated with the relative blocking coefficient. As the relative blocking coefficient increased to a certain value, an exponential growth in the total pressure distortion coefficient occurred, and consequently, the flow field distortion was intensified. In the flow field, a pair of corner vortices were formed at the corner between the flat baffle and the bottom wall of the inlet pipe, and a large separation zone was formed behind the flat baffle and exhibits certain unsteady characteristics.


2015 ◽  
Vol 36 (2) ◽  
pp. 254-258 ◽  
Author(s):  
Julia Louza ◽  
Lynn Mertes ◽  
Thomas Braun ◽  
Robert Gürkov ◽  
Eike Krause

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jung Hwan Ahn ◽  
Jae Hyun Park ◽  
Min Soo Kim ◽  
Hyun Cheol Kang ◽  
Il Seok Kim

AbstractWe aimed to evaluate the efficacy of using airway ultrasonography to select the correct tracheal tube size and insertion depth in pediatric patients who underwent cleft repair surgery as a way to decrease airway complications and adverse events during perioperative periods. Fifty-one patients (age < 28 months) were consecutively divided into conventional (n = 28) and ultrasound (n = 23) groups. Tracheal tube size and insertion depth were determined using the age-based formula and auscultation in the conventional group, whereas using ultrasonographic measurement of subglottic diameter with auscultation and lung ultrasonography in the ultrasound group. We evaluated the initially selected tube size, insertion depth, ventilatory indices, and the incidence of airway complications and adverse events. Tube insertion depth (median [interquartile range]) was significantly greater in the ultrasound group than in the conventional group (13.5 cm [12.5–14.0] vs 13.0 cm [11.8–13.0], P = 0.045). The number of complications and adverse events was significantly higher in the conventional group than in the ultrasound group (32.1% vs 4.3%, P = 0.013). Airway ultrasound application could reduce airway-related complications and adverse events by determining the appropriate tracheal tube size and insertion depth.


Separations ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 79
Author(s):  
Yuekan Zhang ◽  
Jiangbo Ge ◽  
Lanyue Jiang ◽  
Hui Wang ◽  
Junru Yang ◽  
...  

In view of the difficulty of traditional hydrocyclones to meet the requirements of fine classification, a double-overflow three-product (internal overflow, external overflow and underflow) hydrocyclone was designed in this study. Numerical simulation and experimental research methods were used to investigate the effects of double-overflow flow field characteristics and structural parameters (i.e., internal vortex finder diameter and insertion depth) on separation performance. The research results showed that the larger the diameter of the internal vortex finder, the greater the overflow yield and the larger the cut size. The finest internal overflow product can be obtained when the internal vortex finder is 30 mm longer than the external vortex finder. The separation efficiency is highest when the internal vortex finder is 30 mm shorter than the external vortex finder.


1992 ◽  
Vol 12 (2) ◽  
pp. 230-237 ◽  
Author(s):  
Marleen J. Verhaegen ◽  
Michael M. Todd ◽  
David S. Warner ◽  
Bruce James ◽  
Julie B. Weeks

Cerebral blood flow was measured by the H2 clearance method 30 and 60 min after the implantation of 300, 250, 125, or 50 μm diameter platinum–iridium electrodes 2 mm deep into the right parietal cortex of normothermic, normocarbic halothane-anesthetized rats. Another group of animals had 50 μm electrodes inserted 1 mm. In all animals, the presence or absence of a wave of spreading depression (SD) was noted at the time of implantation, with recordings made with glass micropipettes. H2 flow values were compared with those measured in gray matter from the same anatomical region (but from different rats), using [3H]nicotine. The incidence of SD ranged from 60% following insertion of 300 μm electrodes to 0% with 50 μm electrodes. H2 clearance flows also varied with electrode size, from 77 ± 21 ml 100 g−1 min−1 (mean ± standard deviation) with 300 μm electrodes to 110 ± 31 and 111 ± 16 ml 100 g−1 min−1 with 125 and 50 μm electrodes, respectively (insertion depth of 2 mm). A CBF value of 155 ± 60 ml 100 g−1 min−1 was obtained with 50 μm electrodes inserted only 1 mm. Cortical gray matter blood flow measured with [3H]nicotine was 154 ± 35 ml 100 g−1 min−1. When the role of SD in subsequent flow measurements was examined, there was a gradual increase in CBF between 30 and 60 min after electrode insertion in those animals with SD, while no such change was seen in rats without SD. These results indicate that the choice of electrode size and implantation depth influences the measurement of CBF by H2 clearance. CBF values equivalent to those obtained with isotopic techniques can be acutely obtained with small (50 μm diameter) electrodes inserted 1 mm into the cortex. While the occurrence of SD does influence CBF in the period immediately after implantation, a relationship between electrode size and measured flow is present that is independent of SD.


Sign in / Sign up

Export Citation Format

Share Document