Effect of bolted shear connectors on the axial load-bending moment interaction capacity of CFT columns

Structures ◽  
2021 ◽  
Vol 29 ◽  
pp. 92-106
Author(s):  
Masoud Ami ◽  
Seyed Mehdi Zahrai
2011 ◽  
Vol 255-260 ◽  
pp. 718-721
Author(s):  
Z.Y. Wang ◽  
Q.Y. Wang

Problems regarding the combined axial force and bending moment for the behaviour of semi-rigid steel joints under service loading have been recognized in recent studies. As an extended research on the cyclic behaviour of a bolted endplate joint, this study is performed relating to the contribution of column axial force on the cyclic behaviour of the joint. Using finite element analysis, the deteriorations of the joint performance have been evaluated. The preliminary parametric study of the joint is conducted with the consideration of flexibility of the column flange. The column axial force was observed to significantly influence the joint behaviour when the bending of the column flange dominates the failure modes. The reductions of moment resistance predicted by numerical analysis have been compared with codified suggestions. Comments have been made for further consideration of the influence of column axial load in seismic design of bolted endplate joints.


2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Van Binh Phung ◽  
Anh Tuan Nguyen ◽  
Hoang Minh Dang ◽  
Thanh-Phong Dao ◽  
V. N. Duc

The present paper analyzes the vibration issue of thin-walled beams under combined initial axial load and end moment in two cases with different boundary conditions, specifically the simply supported-end and the laterally fixed-end boundary conditions. The analytical expressions for the first natural frequencies of thin-walled beams were derived by two methods that are a method based on the existence of the roots theorem of differential equation systems and the Rayleigh method. In particular, the stability boundary of a beam can be determined directly from its first natural frequency expression. The analytical results are in good agreement with those from the finite element analysis software ANSYS Mechanical APDL. The research results obtained here are useful for those creating tooth blade designs of innovative frame saw machines.


1975 ◽  
Vol 2 (1) ◽  
pp. 98-115
Author(s):  
A. E. Long ◽  
K. Van Dalen ◽  
P. Csagoly

The fatigue behavior of the negative moment region of continuous steel–concrete composite beams under Canadian temperature conditions was studied. Tests were conducted on three 26 ft 0 in. (7.92 m) long beams, continuous over a central support, and on 11 conventional push-out specimens. These were supplemented by a theoretical study of the internal forces in the beams using an iterative method of analysis.The close agreement between measured and theoretical strains and deflections indicated that good interaction was achieved throughout the length of the beams. The beams sustained 500 000 cycles of loading with no serious deterioration of composite action. The pattern of stud failures was consistent from beam to beam and reflected closely the calculated distribution of horizontal shear force at the steel–concrete interface. Stud shear connectors in the negative moment region where the slab had cracked in tension were found to be slightly less effective than studs in the positive bending moment regions.Neither the detailed study of individual connectors in the beams nor the results of the push-out tests show evidence of a reduction in the fatigue life of studs at −20 °F (−29 °C) relative to room temperature. The beams also exhibited no significant difference in their overall performance at these two temperatures.


2013 ◽  
Vol 634-638 ◽  
pp. 2746-2751 ◽  
Author(s):  
Noridah Mohamad ◽  
Najmuddin Hassan

The progressive research upon the issue on renewal technology that can improve the construction industry has initiated the study of Precast Lightweight Foam Concrete Sandwich Panel (PLFP) as an alternative to Industrialize Building System (IBS). This paper reports the analysis of structural behavior of PLFP with double shear connectors under axial load. The PLFP panel consists of two wythes which enclosed a layer of polystyrene layer. Six (6 mm) rebar was used as the vertical and horizontal reinforcement and 9 mm steel bar bent at 450 was used as the connector. Full scaled panel was tested under axial load till failure. It was found that PLFP panel with double shear truss connector has higher ultimate strength capacity compared to PLFP with single shear connectors ehen tested under axial load.


2011 ◽  
Vol 378-379 ◽  
pp. 31-34
Author(s):  
Yi Bo Xiong ◽  
Chun Ming Wang ◽  
Lu Peng

In order to calculate the combined deformations of an Euler-Bernoulli cantilever beam subjected to bending moment, twisting moment, transverse load and axial load, particle flow code in 3 dimensions (PFC3D) is used with parallel bonds model. The computed deformations, including transverse deflections, rotations about axis, maximum normal and shear stresses, were compared with the analytical beam-theory solution in terms of axial tension, axial compression and none axial load, respectively. Between computed results and analytical beam-theory solution, the error bands are greater than 99.7% at the beam tip, while the error of the transverse deflection of the whole beam is less than 0.6%. So, the PFC3D is able to precisely simulate the combined deformation of cantilever beam, and this work has special reference to engineering calculations and designs when PFC is applied to model the mechanical behaviors of continuum materials.