Design resistance of helical seam pipe columns with limited tensile test data

2021 ◽  
Vol 183 ◽  
pp. 106724
Author(s):  
Won-Hee Kang ◽  
Stephen J. Hicks ◽  
Brian Uy ◽  
Farhad Aslani
Author(s):  
Shahrokh Zeinali-Davarani ◽  
Ming-Jay Chow ◽  
Raphaël Turcotte ◽  
Katherine Yanhang Zhang

The passive mechanical response of arteries is believed to be mainly dominated by elastin and collagen fibers. Many arterial diseases are accompanied by significant changes in quantity and as well as the microstructure of these constituents due to the mechanical and biological adaptive processes. In this study we focus on the biaxial tensile test data of elastase-treated porcine aortic tissues [1]. We study the mechanical behavior of aortic tissues under gradual elastin degradation through constitutive modeling and associate the mechanical response with the microstructure of collagen observed in the microscopic images of fresh and digested tissues.


1982 ◽  
Vol 10 (6) ◽  
pp. 263 ◽  
Author(s):  
R Horstman ◽  
KA Peters ◽  
RL Meltzer ◽  
M Bruce Vieth ◽  
R Papirno

2000 ◽  
Vol 277 (2-3) ◽  
pp. 263-273 ◽  
Author(s):  
Thak Sang Byun ◽  
Seok Hun Kim ◽  
Bong Sang Lee ◽  
In Sup Kim ◽  
Jun Hwa Hong

Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3117
Author(s):  
Ihor Dzioba ◽  
Sebastian Lipiec ◽  
Robert Pala ◽  
Piotr Furmanczyk

Tensile uniaxial test is typically used to determine the strength and plasticity of a material. Nominal (engineering) stress-strain relationship is suitable for determining properties when elastic strain dominates (e.g., yield strength, Young’s modulus). For loading conditions where plastic deformation is significant (in front of a crack tip or in a neck), the use of true stress and strain values and the relationship between them are required. Under these conditions, the dependence between the true values of stresses and strains should be treated as a characteristic—a constitutive relationship of the material. This article presents several methodologies to develop a constitutive relationship for S355 steel from tensile test data. The constitutive relationship developed was incorporated into a finite element analysis of the tension test and verified with the measured tensile test data. The method of the constitutive relationship defining takes into account the impact of high plastic strain, the triaxiality stress factor, Lode coefficient, and material weakness due to the formation of microvoids, which leads to obtained correctly results by FEM (finite elements method) calculation. The different variants of constitutive relationships were applied to the FEM loading simulation of the three-point bending SENB (single edge notched bend) specimen to evaluate their applicability to the calculation of mechanical fields in the presence of a crack.


Polymers ◽  
2021 ◽  
Vol 13 (24) ◽  
pp. 4345
Author(s):  
Tuty Fareyhynn Mohammed Fitri ◽  
Azlin Fazlina Osman ◽  
Eid M. Alosime ◽  
Rahimah Othman ◽  
Fatimah Hashim ◽  
...  

Poly(ethylene-vinyl acetate) (PEVA) nanocomposite incorporating dual clay nanofiller (DCN) of surface modified montmorillonite (S-MMT) and bentonite (Bent) was studied for biomedical applications. In order to overcome agglomeration of the DCN, the S-MMT and Bent were subjected to a physical treatment prior to being mixed with the copolymer to form nanocomposite material. The S-MMT and Bent were physically treated to become S-MMT(P) and Bent(pH-s), respectively, that could be more readily dispersed in the copolymer matrix due to increments in their basal spacing and loosening of their tactoid structure. The biocompatibility of both nanofillers was assessed through a fibroblast cell cytotoxicity assay. The mechanical properties of the neat PEVA, PEVA nanocomposites, and PEVA-DCN nanocomposites were evaluated using a tensile test for determining the best S-MMT(P):Bent(pH-s) ratio. The results were supported by morphological studies by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Biostability evaluation of the samples was conducted by comparing the ambient tensile test data with the in vitro tensile test data (after being immersed in simulated body fluid at 37 °C for 3 months). The results were supported by surface degradation analysis. Our results indicate that the cytotoxicity level of both nanofillers reduced upon the physical treatment process, making them safe to be used in low concentration as dual nanofillers in the PEVA-DCN nanocomposite. The results of tensile testing, SEM, and TEM proved that the ratio of 4:1 (S-MMT(P):Bent(pH-s)) provides a greater enhancement in the mechanical properties of the PEVA matrix. The biostability assessment indicated that the PEVA-DCN nanocomposite can achieve much better retention in tensile strength after being subjected to the simulated physiological fluid for 3 months with less surface degradation effect. These findings signify the potential of the S-MMT(P)/Bent(pH-s) as a reinforcing DCN, with simultaneous function as biostabilizing agent to the PEVA copolymer for implant application.


Sign in / Sign up

Export Citation Format

Share Document